ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.
An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.
Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.
Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.
ObjectiveTo evaluate early outcomes of transthoracic pulmonary valve implantation for the treatment of moderate and severe pulmonary regurgitation by using homemade self-expanding valve (SalusTM). MethodsPatients with severe pulmonary regurgitation who underwent transthoracic pulmonary valve implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to November 25, 2022 were prospectively enrolled. The early postoperative complications and improvement of valve and heart function were summarized and analyzed. ResultsA total of 25 patients were enrolled, including 16 males and 9 females, with an average age of 24.5±1.5 years and an average weight of 57.0±3.0 kg. The mean systolic diameters of the bifurcation near the main pulmonary artery, the stenosis of the middle segment of the aorta and near the valve of the right ventricular outflow tract of the patients were 31.8±7.4 mm, 30.6±5.9 mm and 38.4±8.0 mm, respectively. All patients were successfully implanted with valves, and there were no serious complications such as death, coronary compression, stent fracture, valve displacement and infective endocarditis in the early postoperative period. The indexed left atrial longitudinal diameter, indexed right atrial longitudinal diameter, and indexed right ventricular outflow tract anteroposterior diameter decreased significantly after the operation. The degree of tricuspid and pulmonary valve regurgitation and the indexed regurgitation area decreased significantly. The above differences were statistically significant (P<0.05). ConclusionThe early outcomes of transthoracic pulmonary valve implantation with homemade self-expanding pulmonary valve (SalusTM) in the treatment of severe pulmonary regurgitation is relatively good, and the long-term outcomes need to be verified by the long-term follow-up studies with large samples.
Objective To analyze and summarize the early and medium-term outcomes of self-expanding interventional pulmonary valve stent (SalusTM) for right ventricular outflow tract dysfunction with severe pulmonary valve regurgitation. Methods We established strict enrollment and follow-up criteria. Patients who received interventional pulmonary valve in transthoracic implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to July 18, 2023 were prospectively included, and all clinical data of patients were collected and analyzed. ResultsA total of 38 patients with severe pulmonary regurgitation were included, with 23 (60.5%) males and 15 (39.5%) females. The mean age was 24.08±8.12 years, and the mean weight was 57.66±13.54 kg. The preoperative mean right ventricular end-diastolic volume index (RVEDVI) and right ventricular end-systolic volume index (RVESVI) were 151.83±42.84 mL/m2 and 83.34±33.05 mL/m2, respectively. All patients successfully underwent transcatheter self-expandable pulmonary valve implantation, with 3 (7.9%) patients experiencing valve stent displacement during the procedure. Perioperative complications included 1 (2.6%) patient of postoperative inferior wall myocardial infarction and 1 (2.6%) patient of poor wound healing. The median follow-up time was 12.00 (6.00, 17.50) months. During the follow-up period, there were no deaths or reinterventions, and no patients had recurrent severe pulmonary regurgitation. Three (7.9%) patients experienced chest tightness and chest pain, and 1 (2.6%) patient developed frequent ventricular premature beats. Compared with preoperative values, the right atrial diameter, right ventricular diameter, and tricuspid annular plane systolic excursion were significantly reduced at 6 months and 1 year postoperatively, with improvement in the degree of pulmonary regurgitation (P<0.01). Compared with preoperative values, RVEDVI and RVESVI decreased to 109.51±17.13 mL/m2 and 55.88±15.66 mL/m2, respectively, at 1 year postoperatively (P<0.01). Conclusion Self-expanding interventional pulmonary valve in transthoracic implantation is safe and effective for severe pulmonary valve regurgitation and shows good clinical and hemodynamic results in one-year outcome.