west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "YANG Ting" 8 results
  • Effects of low-power wireless power transfer system on memory behavior and part of physiological properties of mice

    Wireless power transfer (WPT) is a new power transmission way, which can be widely used in electric vehicles and other fields. Its electromagnetic environment must be analyzed to ensure safe application. A low-power wireless power transfer system experimental platform was built, with 25 W receiving power and 47 kHz resonant frequency, which was used to carry out animal experiments. Treatment mice were exposed to environment of wireless power transfer system for 5 h a day and 6 days as one cycle. At the end of every cycle, learning memory behavior of mice were detected in T-shaped maze. The exposure experiment lasted for 12 weeks. Finally, immune parameters, sex hormones and part of organ physiological structure were detected. The results are as follows: as exposure time increased, memory behavior of mice did not change obviously with no statistical difference in sex hormone either (P > 0.05), the concentration of immune factors including tumor necrosis factor-α (TNF-α), interleukin 6 (IL-6) and interleukin-1 beta (IL-1β) significantly increased (P < 0.05), and the structure of some organs showed some changes. The experimental results show that the environment of the wireless power transfer system has no effect on the memory behavior of mice, and has some effect on physiological properties of mice.

    Release date:2020-06-28 07:05 Export PDF Favorites Scan
  • Efficacy and safety of 89SrCl2 for bone metastases: a meta-analysis

    ObjectiveTo systematically review the efficacy and safety of 89SrCl2 for bone metastases.MethodsDatabases including PubMed, EMbase, The Cochrane Library (Issue 12, 2016), MEDLINE, CBM, VIP, CNKI and WanFang Data were electronically searched from inception to December 2016 to collect randomized controlled trials (RCT) about 89SrCl2 in the treatment of bone metastases. Two reviewers independently screened literature, extracted data, and assessed the risk of bias of included studies. Then meta-analysis was performed by using RevMan 5.3 software.ResultsA total of 19 RCTs involving 1 899 patients were included. The results of meta-analysis showed that: compared to the group without 89SrCl2, group of 89SrCl2 combined with other treatments had benefits for complete relief of bone pain (RR=1.53, 95%CI 1.16 to 2.01, P=0.002), total relief of bone pain (RR=1.33, 95%CI 1.22 to 1.45, P<0.001), bone metastases complete response rate (RR=1.61, 95%CI 1.20 to 2.16, P=0.002), bone metastases total response rate (RR=1.61, 95%CI 1.26 to 2.08, P<0.001), improvement of quality of life (RR=1.44, 95%CI 1.06 to 1.97, P=0.02). The proportion of pain flare (RR=10.35, 95%CI 2.01 to 53.37, P=0.005), leucopenia (RR=2.49, 95%CI 1.84 to 3.37, P<0.001) and thrombocytopenia (RR=2.64, 95%CI 1.76 to 3.97, P<0.001) in the 89SrCl2 group were higher than that in the control group.Conclusion89SrCl2 combined with the other treatments is better for bone metastases than without 89SrCl2. Due to the limited quantity and quality of included studies, the above results should be verify by more high quality studies.

    Release date:2017-09-15 11:24 Export PDF Favorites Scan
  • Hemodynamic Monitoring by Pulse-Indicated Continuous Cardiac Output Analysis During Lung Transplantation

    Objective To explore the hemodynamic monitoring value of pulse-indicated continuous cardiac output( PiCCO) during lung transplantation. Methods Twenty patients with end-stage lung disease undergone lung transplantation were enrolled. Hemodynamic states were monitored by PiCCO and Swan-Ganz standard thermodilution pulmonary artery catheter( PAC) simultaneously at six stages throughout the study. Changes in the variables were calculated by subtracting the first fromthe second measurement( Δ1 ) and so on ( Δ1 to Δ5 ) . Results The linear correlation between intra-thoracic blood volume index( ITBVI) and stroke volume index( SVIpa) was significant ( r = 0. 654, P lt; 0. 05) , whereas pulmonary artery wedge pressure ( PAWP) poorly correlated with SVIpa( P gt; 0. 05) . Changes in ITBVI correlated with changes in SVIpa ( Δ1 , r =0. 621; Δ2 , r = 0. 784; Δ3 , r = 0. 713; Δ4 , r = 0. 740; Δ5 , r = 0. 747; all P lt; 0. 05) , whereas PAWP failed. The mean bias between CIart and CIpa was ( 0. 09 ±0. 5) L·min-1 ·m-2 ; the limit of agreement was ( - 0. 89 ~1. 07) L·min-1 ·m-2 . Conclusions There is good correlation between the two methods of PiCCO and PAC for reflecting the change of heart preload. PiCCO is reliable in hemodynamic monitoring in patients undergone lung transplantation.

    Release date:2016-08-30 11:53 Export PDF Favorites Scan
  • The role of cystatin C in evaluating the severity and predicting the hospital mortality of patients with community-acquired pneumonia

    Objective To determine the role of serum cystatin C in evaluating the severity and predicting in-hospital mortality in patients with community-acquired pneumonia (CAP). Methods The clinical data of 176 patients with CAP treated between January 2015 and October 2016 were collected in a retrospective way. The CURB-65 score was used to assess the severity. The serum levels of cystatin C and C-reactive protein (CRP) on admission were measured. The correlations between cystatin C and CURB-65 score and between cystatin C and CRP were calculated. Receiver operating characteristic curve was used to determine the ability of cystatin C in predicting in-hospital mortality. Results The serum level of cystatin C increased with the increasing CURB-65 score (P<0.001). The serum level of cystatin C was correlated positively with CRP level (rs=0.190, P<0.011). There were 22 patients died in hospital, the mean serum cystatin C level of non-survivor was significantly higher than that of survivors [(1.51±0.56)vs. (1.02±0.29) mg/L, P<0.001]. At a cut-off 1.18 mg/L, the sensitivity and specificity of cystatin C in predicting in-hospital mortality were 68.18% and 81.17%, respectively. The area under the receiver operating characteristic curve was 0.793. The combination of cystatin C and CRP increased the predictive accuracy for in-hospital mortality. Conclusion Cystatin C level increases with the increaseing severity of CAP, and it may be a clinical biomarker to evaluate the severity and prognosis of patients with CAP.

    Release date:2018-01-23 02:34 Export PDF Favorites Scan
  • Biocompatibility research of true bone ceramics

    Objective To investigate the biocompatibility of true bone ceramic (TBC) and provide experimental basis for clinic application. Methods TBC was prepared from healthy adult bovine cancellous bone by deproteinization and high temperature calcinations. Mouse fibroblast cell line (L929 cells) were cultured with the leaching liquor of TBC in vitro, and the cytotoxicity was evaluated at 2nd, 4th, and 7th days. L929 cells were inoculated into the TBC and cultured for 4 days. The cell adhesion and proliferation on the surface of the TBC were observed by scanning electron microscopy, and evaluated the cell compatibility of TBC. Ten New Zealand white rabbits were divided into 2 groups, and drilled holes at the tibia of both hind limbs. TBC and hydroxyapatite (HA) were implanted into the left side (experimental group) and the right side (control group), respectively. And the biocompatibility of TBC was evaluated by general observation and histological observation at 4 and 26 weeks after implantation. Results Cytotoxicity test showed that the cytotoxicity level of leaching liquor of TBC was grade 0-1. Cell compatibility experiments showed that the L929 cells adhered well on the surface of TBC and migrated into the pores. The implantation test in vivo showed that experimental group and control group both had mild or moderate inflammatory response at 4 weeks, and new bone formation occurred. At 26 weeks, there was no inflammatory reaction observed in both groups, and new bone formation was observed in varying degrees. Conclusion TBC have good biocompatibility and can be used to repair bone defect in clinic.

    Release date:2017-10-10 03:58 Export PDF Favorites Scan
  • Preliminary study on true bone ceramics for alveolar ridge preservation in dogs

    ObjectiveTo study the preservation effect of true bone ceramics (TBC) prepared by high-temperature calcination of bovine bone on alveolar ridge of canine extraction socket.MethodsSix healthy Beagle dogs (aged 1.5-2 years) were selected to extract the second and fourth premolars of both mandibles and the second premolars of the maxilla. The left extraction socket was implanted with TBC as the experimental group, and the right side was implanted with the calcined bovine bone (CBB) as the control group, to observe the alveolar ridge preservation effect. Three dogs were euthanized after general observation at 1 and 6 months after operation respectively. After separating the maxilla and mandible, cone beam CT (CBCT) was performed to measure the average gray value of the graft site and the adjacent reference area (the area between the roots of the adjacent third premolar) and calculate the gray scale ratio between the bone graft site and the reference area. Histological observation was made on the bone graft site to evaluate the new bone formation.ResultsGeneral observation showed that the wounds of both groups were basically healed at 2 weeks after operation, and the bone graft materials were not exposed. The wounds healed well at 1 and 6 months after operation without swelling. The results of CBCT showed that the residual material was found in both groups at 1 month after operation, and no significant residual material was found in both groups at 6 months after operation, and the alveolar ridge height of the bone graft area was not significantly reduced. There was no significant difference in the bone mineral density between the experimental group and the control group. The gray scale ratios of the experimental group at 1 month and 6 months after operation were 0.97±0.14 and 0.93±0.06, respectively, and were 0.99±0.16 and 0.94±0.05 in control group, showing no significant difference between the two groups (t=−1.030, P=0.333; t=−0.770, P=0.466). HE staining observation showed that a large number of bone graft materials did not degrade and new bone formed around the grafts in both groups at 1 month after operation; the bone graft materials were absorbed and a large number of new bones were formed in both groups at 6 months after operation.ConclusionTBC can maintain bone mineral density and have good osteoconductivity in the alveolar ridge site preservation experiment of dogs, and can be used for alveolar ridge site preservation.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
  • Implementation of Bayesian network meta-analysis with BUGSnet package in R software

    BUGSnet is a powerful R project package for Bayesian network meta-analysis. The package is based on JAGS and enables high-quality Bayesian network meta-analysis according to recognized reporting guidelines (PRISMA, ISPOR-AMPC-NCA and NICE-DSU). In this paper, we introduced the procedure of the BUGSnet package for Bayesian network meta-analysis through an example of network meta-analysis of steroid adjuvant treatment of pemphigus with continuous or dichotomous data.

    Release date: Export PDF Favorites Scan
  • Preparation and bone repair capability of a new plastic bone filler material

    Objective To prepare a new plastic bone filler material with adhesive carrier and matrix particles derived from human bone, and evaluate its safety and osteoinductive ability through animal tests. MethodsThe human long bones donated voluntarily were prepared into decalcified bone matrix (DBM) by crushing, cleaning, and demineralization, and then the DBM was prepared into bone matrix gelatin (BMG) by warm bath method, and the BMG and DBM were mixed to prepare the experimental group’s plastic bone filler material; DBM was used as control group. Fifteen healthy male thymus-free nude mice aged 6-9 weeks were used to prepare intermuscular space between gluteus medius and gluteus maximus muscles, and all of them were implanted with experimental group materials. The animals were sacrificed at 1, 4, and 6 weeks after operation, and the ectopic osteogenic effect was evaluated by HE staining. Eight 9-month-old Japanese large-ear rabbits were selected to prepare 6-mm-diameter defects at the condyles of both hind legs, and the left and right sides were filled with the materials of the experimental group and the control group respectively. The animals were sacrificed at 12 and 26 weeks after operation, and the effect of bone defect repair were evaluated by Micro-CT and HE staining. Results In ectopic osteogenesis experiment, HE staining showed that a large number of chondrocytes could be observed at 1 week after operation, and obvious newly formed cartilage tissue could be observed at 4 and 6 weeks after operation. For the rabbit condyle bone filling experiment, HE staining showed that at 12 weeks after operation, part of the materials were absorbed, and new cartilage could be observed in both experimental and control groups; at 26 weeks after operation, the most of the materials were absorbed, and large amount of new bone could be observed in the 2 groups, while new bone unit structure could be observed in the experimental group. Micro-CT observation showed that the bone formation rate and area of the experimental group were better than those of the control group. The measurement of bone morphometric parameters showed that the parameters at 26 weeks after operation in both groups were significantly higher than those at 12 weeks after operation (P<0.05). At 12 weeks after operation, the bone mineral density and bone volume fraction in the experimental group were significantly higher than those in the control group (P<0.05), and there was no significant difference between the two groups in trabecular thickness (P>0.05). At 26 weeks after operation, the bone mineral density of the experimental group was significantly higher than that of the control group (P<0.05). There was no significant difference in bone volume fraction and trabecular thickness between the two groups (P>0.05). Conclusion The new plastic bone filler material is an excellent bone filler material with good biosafety and osteoinductive activity.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content