west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "YAO Qingqiang" 4 results
  • Dopamine modified and cartilage derived morphogenetic protein 1 laden polycaprolactone-hydroxyapatite composite scaffolds fabricated by three-dimensional printing improve chondrogenic differentiation of human bone marrow mesenchymal stem cells

    ObjectiveTo prepare dopamine modified and cartilage derived morphogenetic protein 1 (CDMP1) laden polycaprolactone-hydroxyapatite (PCL-HA) composite scaffolds by three-dimensional (3D) printing and evaluate the effect of 3D scaffolds on in vitro chondrogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs).MethodsA dimensional porous PCL-HA scaffold was fabricated by 3D printing. Dopamine was used to modify the surface of PCL-HA and then CDMP-1 was loaded into scaffolds. The surface microstructure was observed by scanning electron microscope (SEM) and porosity and water static contact angle were also detected. The cytological experiment in vitro were randomly divided into 3 groups: group A (PCL-HA scaffolds), group B (dopamine modified PCL-HA scaffolds), and group C (dopamine modified and CDMP-1 laden PCL-HA scaffolds). The hBMSCs were seeded into three scaffolds, in chondrogenic culture conditions, the cell adhesive rate, the cell proliferation (MTT assay), and cell activity (Live-Dead staining) were analyzed; and the gene expressions of collagen type Ⅱ and Aggrecan were detected by real-time fluorescent quantitative PCR.ResultsThe scaffolds in 3 groups were all showed a cross-linked and pore interconnected with pore size of 400–500 μm, porosity of 56%, and fiber orientation of 0°/90°. For dopamine modification, the scaffolds in groups B and C were dark brown while in group A was white. Similarly, water static contact angle was from 76° of group A to 0° of groups B and C. After cultured for 24 hours, the cell adhesion rate of groups A, B, and C was 34.3%±3.5%, 48.3%±1.5%, and 57.4%±2.5% respectively, showing significant differences between groups (P<0.05). Live/Dead staining showed good cell activity of cells in 3 groups. MTT test showed that hBMSCs proliferated well in 3 groups and the absorbance (A) value was increased with time. The A value in group C was significantly higher than that in groups B and A, and in group B than in group A after cultured for 4, 7, 14, and 21 days, all showing significant differences (P<0.05). The mRNA relative expression of collagen type Ⅱ and Aggrecan increased gradually with time in 3 groups. The mRNA relative expression of collagen type Ⅱafter cultured for 7, 14, and 21 days, and the mRNA relative expression of Aggrecan after cultured for 14 and 21 days in group C were significantly higher than those in groups A and B, and in group B than in group A, all showing significant differences (P<0.05).ConclusionCo-culture of dopamine modified and CDMP1 laden PCL-HA scaffolds and hBMSCs in vitro can promote hBMSCs’ adhesion, proliferation, and chondrogenic differentiation.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Clinical study of three-dimensional printed navigation template assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printed navigation templates assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus.MethodsBetween April 2013 and February 2015, 28 patients (28 feet) with moderate and severe hallux valgus who underwent Ludloff osteotomy were randomly divided into 2 groups (n=14). In group A, the patients were treated with Ludloff osteotomy assissted with a 3D printed navigation template. In group B, the patients were treated with traditional Ludloff osteotomy. There was no significant difference in gender, age, affected side, and clinical classification between 2 groups (P>0.05). The operation time and intraoperative blood loss were recorded. The ankle function of the foot at preoperation, immediate after operation, and last follow-up were assessed by the American Orthopedic Foot and Ankle Society (AOFAS) score. Besides, the X-ray film were taken to assess the hallux valgus angle (HVA), intermetatarsal angle (IMA), and the first metatarsal length shortening.ResultsAll patients were followed up 18-40 months (mean, 26.4 months). The operation time and intraoperative blood loss in group A were significantly less than those in group B (P<0.05). The HVA, IMA, and AOFAS scores in groups A and B at immediate after operaton and last follow-up were sinificantly improved when compared with preoperative values (P<0.05); but no significant difference was found between at immediate after operation and at last follow-up (P>0.05). No significant difference was found in HVA and IMA between group A and group B at difference time points (P>0.05). There were significant differences in AOFAS score and the first metatarsal length shortening at immediate after operation and at last follow-up between 2 groups (P<0.05). Except 1 case of metastatic metatarsalgia in group B, there was no other operative complications in both groups.Conclusion3D printed navigation template assisted Ludloff osteotomy can provide accurate preoperative planning and intraoperative osteotomy. It is an ideal method for moderate and severe hallux valgus.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • Theranostics of osteosarcoma and lung metastasis with new integrin αvβ3 receptor targeted radiotracers

    ObjectiveTo investigate the value of integrin αvβ3 targeted microPET/CT imaging with 68Ga-NODAGA-RGD2 as radiotracer for the detection of osteosarcoma and theranostics of osteosarcoma lung metastasis.MethodsThe 68Ga-NODAGA-RGD2 and 177Lu-NODAGA-RGD2 were prepared via one-step method and their stability and integrin αvβ3 binding specificity were investigated in vitro. Forty-one nude mice were injected with human MG63 osteosarcoma to established the animal model bearing subcutaneous osteosarcoma (n=21), osteosarcoma in tibia (n=5), and osteosarcoma pulmonary metastatic (n=15). The microPET-CT imaging was carried out in 3 animal models at 1 hour after tail vein injection of 68Ga-NODAGA-RGD2. Biodistribution study of 68Ga-NODAGA-RGD2 was performed in animal model bearing subcutaneous osteosarcoma at 10, 60, and 120 minutes. The animal model bearing pulmonary metastatic osteosarcoma was injected with 177Lu-NODAGA-RGD2 at 7 weeks after model establishment to observe the therapeutic effect of pulmonary metastatic osteosarcoma. Histological and immunohistochemistry examinations were also done to confirm the establishment of animal model and integrin β3 expression in animal models bearing subcutaneous osteosarcoma and bearing pulmonary metastatic osteosarcoma.Results68Ga-NODAGA-RGD2 and 177Lu-NODAGA-RGD2 had good stability in vitro with the 50% inhibitory concentration value of (5.0±1.1) and (6.5±0.8) nmol/L, respectively. The radiochemical purity of 68Ga-NODAGA-RGD2 at 1, 4, and 8 hours was 98.5%±0.3%, 98.3%±0.5%, and 97.9%±0.4%; while the radiochemical purity of 177Lu-NODAGA-RGD2 at 1, 7, and 14 days was 99.3%±0.7%, 98.7%±1.2%, and 96.0%±2.8%. 68Ga-NODAGA-RGD2 microPET-CT showed that the accumulation of 68Ga-NODAGA-RGD2 in animal models bearing subcutaneous osteosarcoma and osteosarcoma in tibia and in lung metastasis as small as 1-2 mm in diameter of animal model bearing pulmonary metastatic osteosarcoma. Biodistribution study of 68Ga-NODAGA-RGD2 in animal model bearing subcutaneous osteosarcoma revealed rapid clearance from blood with tumor peak uptake of (3.85±0.84) %ID/g at 120 minutes. The distribution of 177Lu-NODAGA-RGD2 in lung metastasis was similar with 68Ga-NODAGA-RGD2. The number and size of osteosarcoma metastasis decreased at 2 weeks after 177Lu-NODAGA-RGD2 administration and integrin targeting specificity was confirmed by pathology examination.Conclusion68Ga-NODAGA-RGD2 was potential for positive imaging and early detection of osteosarcoma and metastasis. Targeted radiotherapy with 177Lu-NODAGA-RGD2 was one potential alternative for osteosarcoma lung metastasis.

    Release date:2019-01-25 09:40 Export PDF Favorites Scan
  • Application of individualized transiliac crest nail-grafting guide plate in deep pelvic external fixator implantation

    Objective To explore the application of individualized transiliac crest nail-grafting guide plate prepared by computer-aided design and three-dimensional (3D) printing technology in deep pelvic external fixator implantation. Methods Five patients with pelvic fractures were collected between May 2017 and February 2018. There were 4 females and 1 male with an average age of 52 years (range, 29-68 years). Pelvic fractures were classified as type B in 3 cases and type C in 2 cases by Tile classification. The interval between injury and operation was 6-14 days (mean, 9 days). The preoperative CT images of pelvic fractures were collected. The data was reconstructed by 3D imaging reconstruction workstation. An individualized transiliac crest nail-grafting guide plate was designed on the virtual 3D model. The individualized transiliac crest nail-grafting guide plate and the solid pelvic model were produced with the 3D printing technology. The individualized transiliac crest nail-grafting guide plate was used for intraoperative deep pin position on iliac crest after the preoperative simulation. The follow-up CT scans were used to determine the differences in distance from anterior superior iliac spine, convergence angle, and caudal angle between the preoperative plan and postoperative measurement. Results During the operation, the individualized transiliac crest nail-grafting guide plate was used to guide the placement of 20 pins. X-ray film and CT examination showed that all pins were well positioned. The average depth of pins was 83.16 mm (range, 70.13-100.53 mm). Fitted 3D reconstruction images showed that the entry point and orientation of the pins were all consistent with preoperative schemes. Compared with the planned nail path, there was no significant difference in the distance from anterior superior iliac spine, convergence angle, and caudal angle in the actual nail path (P>0.05). No loosening and rupture of pin, no damage of blood vessels and nerve, and shallow or deep infection occurred during 3 months follow-up, and the incisions healed by first intention. All patients were satisfied with the treatment process. The ranges of motion of hip and knee were normal, and the visual analogue scale (VAS) score was 0-3 (mean, 0.5). Conclusion The individualized transiliac crest nail-grafting guide plate technique is the improvement of traditional technique. It can increase accuracy and effective depth of pin position, enable patients to obtain pelvic mechanical stability quickly after operation, and reduce the risk of complications related to nail path.

    Release date:2019-08-23 01:54 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content