west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "YE Ye" 3 results
  • Research progress of medial buttress plate assisted fixation for femoral neck fractures in young adults

    ObjectiveTo summarize the research progress of medial buttress plate assisted fixation for femoral neck fractures in young adults.MethodsThe literature about buttress plate assisted fixation for femoral neck fractures in young adults was widely reviewed and analyzed. The design principle, background, biomechanical characteristics, and clinical results of buttress plate were summarized.ResultsMedial buttress plate assisted fixation is the latest treatment of femoral neck fractures in young adults, which can convert the shear force at the fracture sides into compression force and promote fracture healing. Medial buttress plate can improve the biomechanical stability of femoral neck fractures and reduce the maximum stress of fixation implants. In clinical, the medial buttress plate can maintain fracture reduction, reduce the incidences of nonunion and surgical failure, and improve hip joint function.ConclusionMedial buttress plate assisted fixation can achieve good effectiveness for femoral neck fractures in young adults. However, due to the preliminary application, its indications, fixation implants, and long-term effectiveness need to be further studied and improved.

    Release date:2020-11-27 06:47 Export PDF Favorites Scan
  • Application of “diamond concept” in treatment of femoral shaft fractures nonunion after intramedullary fixation

    ObjectiveTo investigate the effectiveness of the treatment under the guidance of “diamond concept” for femoral shaft fractures nonunion after intramedullary fixation.MethodsBetween January 2014 and December 2016, 21 cases of femoral shaft fractures nonunion after intramedullary fixation were treated with auxiliary plate fixation combined with autogenous iliac graft, and autologous bone marrow concentrate and platelet-rich plasma (PRP) gel under the guidance of the “diamond concept”. There were 13 males and 8 females, with an average age of 32.5 years (range, 17-48 years). All fractures were closed femoral shaft fractures. Four patients underwent internal fixation with plate and resulted in nonunion, then they were fixed with intramedullary nails, but did not heal either. The rest 17 patients were fixed with intramedullary nailing. Fracture nonunion classification: 4 cases of hypertrophic nonunion, 17 cases of atrophic nonunion; the length of bone defect was 1-3 mm; the duration from the last treatment to the current treatment was 10-23 months (mean, 14.3 months). The operation time, intraoperative blood loss, the time between operation and full loading, fracture healing time, and complications were recorded. The visual analogue scale (VAS) score and the imaging system of fracture healing of the extremities (RUST) of patients before operation and at last follow-up were recorded to evaluate the fracture healing; the function of the affected limb was evaluated according to the Schatzker-Lambert efficacy score standard at last follow-up.ResultsThe operation time was 105-160 minutes, with an average of 125.6 minutes; the intraoperative blood loss was 160-580 mL, with an average of 370.5 mL. All incisions healed by first intention, without vascular or nerve injury. All patients were followed up 22-46 months (mean, 26.5 months). All the fractures healed, with a fracture healing time of 3-7 months (mean, 4.8 months). During the follow-up, there was no infection, loosening, implant breakage, re-fracture, and other complications. The VAS score at last follow-up was 0.8±0.3, showing significant difference (t=7.235, P=0.000) when compared with preoperative score (5.2±3.7); the RUST score was 3.4±0.3, which was significantly higher than the preoperative score (1.5±0.7) (t=8.336, P=0.000). According to the Schatzker-Lambert effectiveness evaluation standard, the limb function was excellent in 16 cases, good in 4 cases, fair in 1 case, and the excellent and good rate was 95.42%.ConclusionNonunion after intramedullary fixation of femoral fracture treated with auxiliary plate combined with autogenous iliac graft, autogenous bone marrow concentration and PRP gel in accordance with the “diamond concept” can not only restore the stability of the fracture ends, but also improves the biological environment of the fracture site, and can improve the rate of fracture healing.

    Release date:2020-08-19 03:53 Export PDF Favorites Scan
  • A multicenter randomized controlled trial of domestic robot-assisted and conventional total knee arthroplasty

    ObjectiveTo investigate the accuracy, safety, and short-term effectiveness of a domestic robot-assisted system in total knee arthroplasty (TKA) by a multicenter randomized controlled trial. Methods Between December 2021 and February 2023, 138 patients with knee osteoarthritis who received TKA in 5 clinical centers were prospectively collected, and 134 patients met the inclusion criteria were randomly assigned to either a trial group (n=68) or a control group (n=66). Seven patients had lost follow-up and missing data, so they were excluded and the remaining 127 patients were included for analysis, including 66 patients in the trial group and 61 patients in the control group. There was no significant difference (P>0.05) in gender, age, body mass index, side, duration of osteoarthritis, Kellgren-Lawrence grading, preoperative Knee Society Score (KSS) and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score between the two groups. The trial group completed the TKA by domestic robot-assisted osteotomy according to the preoperative CT-based surgical planning. The control group was performed by traditional osteotomy plate combined with soft tissue release. Total operation time, osteotomy time of femoral/tibial side, intraoperative blood loss, and postoperative complications were recorded and compared between the two groups. The radiographs were taken at 5 and 90 days after operation, and hip-knee-ankle angle (HKA), lateral distal angle of femur (LDFA), and posterior tibial slope (PTS) were measured. The difference between the measured values of the above indexes at two time points after operation and the preoperative planning target values was calculated, and the absolute value (absolute error) was taken for comparison between the two groups. The postoperative recovery of lower limb alignment was judged and the accuracy was calculated. KSS score and WOMAC score were used to evaluate the knee joint function of patients before operation and at 90 days after operation. The improvement rates of KSS score and WOMAC score were calculated. The function, stability, and convenience of the robot-assisted system were evaluated by the surgeons. ResultsThe total operation time and femoral osteotomy time of the trial group were significantly longer than those of the control group (P<0.05). There was no significant difference in the tibial osteotomy time and the amount of intraoperative blood loss between the two groups (P>0.05). The incisions of both groups healed by first intention after operation, and there was no infection around the prosthesis. Nine patients in the trial group and 8 in the control group developed lower extremity vascular thrombosis, all of which were calf intermuscular venous thrombosis, and there was no significant difference in the incidence of complications (P>0.05). All patients were followed up 90 days. There was no significant difference in KSS score and WOMAC score between the two groups at 90 days after operation (P>0.05). There was significant difference in the improvement rate of KSS score between the two groups (P<0.05), while there was no significant difference in the improvement rate of WOMAC score between the two groups (P>0.05). Radiological results showed that the absolute errors of HKA and LDFA in the trial group were significantly smaller than those in the control group at 5 and 90 days after operation (P<0.05), and the recovery accuracy of lower limb alignment was significantly higher than that in control group (P<0.05). The absolute error of PTS in the trial group was significantly smaller than that in the control group at 5 days after operation (P<0.05), but there was no significant difference at 90 days between the two groups (P>0.05). The functional satisfaction rate of the robot-assisted system was 98.5% (65/66), and the satisfaction rates of stability and convenience were 100% (66/66). ConclusionDomestic robot-assisted TKA is a safe and effective surgical treatment for knee osteoarthritis, which can achieve favorable lower limb alignment reconstruction, precise implant of prosthesis, and satisfactory functional recovery.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content