Objective To explore the effects of different humidification and heating strategies during non-invasive positive pressure ventilation( NIPPV) in patients with ALI/ARDS. Methods A total of 45 patients with ALI/ARDS were randomly divided into three groups to receive NIPPV with different humidification and heating strategies, ie. Group A ( humidification with a 370 Humidifier without heating) ,group B ( humidification with a 370 Humidifier along with a MR410 Heater) , and group C ( humidification and heating with aMR850 Humidifier, and a RT308 circuit heater) . The changes of air temperature, absolute humidity, relative humidity, sputum thickness and patient comfort were compared between the three groups. Sputum thickness was evaluated with AWSS scoring system. Results After humidification and heating, the air temperature, absolute humidity and AWSS score improved significantly in group B [ elevated from ( 23. 9 ±1. 0) ℃, (9.8 ±1. 3) mg/L and 2. 0 ±0. 7 respectively to ( 30. 3 ±1. 7) ℃, ( 31. 0 ±2. 3)mg/L and ( 3. 0 ±0. 9) respectively, P lt; 0. 001] and group C [ elevated from( 23. 8 ±1. 0) , ( 9. 8 ±1. 5)mg/L and ( 2. 1 ±0. 7) respectively to ( 34. 0 ±1. 1) ℃, ( 43.8 ±2. 5) mg /L and 3. 5 ±1. 0 respectively,P lt; 0. 001] . Air temperature and absolute humidity were significantly higher in group C than those in group B( P lt; 0. 001) . Of all the parameters, only absolute humidity showed a significant improvment in group A [ elevated from( 9. 9 ±1. 6) mg/L to ( 11. 9 ±0. 9) mg/L, P lt; 0. 001] . The degree of comfort in group C was significantly higher than that in group A and B [ 8. 0 ±1. 7 vs 5. 0 ±1. 2 and 3. 0 ±0. 4, respectively, P lt;0. 001] . In group A seven patients were switched to group C because of discomfort, four accepted NIPPV continuously, and two avoided invasive mechanical ventilation eventually. In group B three patients were switched to group C because of intolerance of too much condensed water in the breathing circuit, all of them accepted NIPPV continuously, and one avoided invasive mechanical ventilation eventually. Conclusions Compared with mere humidification or humidification with heating humidifier, humidification with heating humidifier and circuit heating during NIPPV can improve the absolute humidity, air temperature and patient comfort,meanwhile decreasing the sputumthickness of patients with ALI/ARDS.
Objective To observe the changes of soluble triggering receptor expressed on myeloid cell-1 ( sTREM-1) and inflammatory mediators levels in plasma of severe pneumonia patients, and explore the significance of systemic inflammatory response state.Methods Plasma levels of sTREM-1, tumor necrosis factor-α ( TNF-α) and interleukin-10 ( IL-10) were examined in 40 patients with severe pneumonia, 25 patients with uncomplicated pneumonia, and 15 healthy volunteers. Plasma levels of TNF-α,IL-10 and sTREM-1 in survival and non-survival severe pneumoniawere observed on days 1,4, 7 and the day of discharge or death.Results Plasma levels of TNF-α, IL-10, and sTREM-1 [ ( 44. 25 ±10. 81) pg/mL,( 58. 21 ±16. 41) pg/mL, ( 51. 75 ±18. 51) pg/mL, respectively] in the patients with severe pneumonia were higher than those with uncomplicated pneumonia [ ( 24.6 ±6. 45) pg/mL, ( 24. 56 ±7. 1) pg/mL,( 25. 55 ±7. 72) pg/mL, respectively] and the normal controls [ ( 13. 82 ±4. 04) pg/mL, ( 15. 30 ±4. 45)pg/mL, ( 14. 37 ±4. 82) pg/mL, respectively] ( P lt;0. 001) . Plasma levels of TNF-α, IL-10, and sTREM-1 were gradually decreased in the survivors, while maintained at high levels or increased in the non-survivors.The levels of these mediators were all significantly higher in the non-survivors than the survivors at all time points. The ratio of TNF-α/ IL-10 level was higher in the severe pneumonia patients than the uncomplicated pneumonia patients and the control subjects ( 1. 286 ±0. 177 vs. 1. 077 ±0. 410 and 0. 932 ±0. 154) on day 1.The ratio of TNF-α/IL-10 level was higher in the non-survivors than the survivors at all time points. There was negative correlation between plasma levels of sTREM-1 and TNF-αon day 1 ( r = - 0. 479, P =0. 002) ,and positive correlation between plasma levels of sTREM-1 and IL-10 on day 1 ( r = 0. 326, P = 0. 040) .Conclusions There are excessive release of inflammatory mediators and unbalanced systemic inflammatory response in patients with severe pneumonia, especially in non-survivors. sTREM-1, TNF-α and IL-10 are involved in the inflammatory response, and their levels may reflect the prognosis.
Objective To compare the efficacy and safety of different airway humidification methods in patients with tracheotomy in weaning process. Methods Twelve patients with tracheotomy in the medical intensive care unit ( MICU) of the First Affiliated Hospital of Sue Yat-sen University fromSeptember 2008 to August 2009 were enrolled in which 45 case /times weaning tests in three different humidification ways were performed( 15 cases in each group) . Wet square gauze method was used in group A and traditional intermittent wet fluid drip method was used in group B. In group C, MR850 humidifier device, RT200 Venturi tube and T tube device were used to perform humidification. Comparisons were carried out between the three groups on sputum viscosity, comfort of patients before and after humidification, length of weaning time, frequencies of irritating coughs and phlegm formation during test period. Sputum viscosity was evaluated by airway secretion score ( AWSS) .Results There was no significant difference of sputum viscosity assessed by AWSS in group A before and after humidification( P gt; 0. 05 ) while AWSS was significantly increased in group B and group C ( P lt;0. 01) , implied that sputum viscosity was significantly lower than that of group A ( P lt;0. 05) . The scores of patients’comfortwere 3. 0 ±0. 4, 5. 0 ±1. 2, and 8. 0 ±1. 7 in groups A, B, and C respectively which mean that the patients in group C felt more comfortable than those in group A and group B ( P lt;0. 01) . Cough frequencies of groups A, B and C per hour were 0. 8,2. 6,and 0. 4 times/hour respectively in which the frequency of group B was significantly higher than those of group A and group C ( P lt;0. 01) . The frequency of phlegm formation in group A was 7 times in 15-times offline record, which was significantly higher than those in group B and group C ( P lt;0. 01) . Conclusions For the patients with tracheotomy in weaning process, MR850 humidifier device, RT200 Venturi tube and T tube device for humidification is superior in reducing sputum viscosity and phlegm formation, improving patient comfort, and reducing the occurrence of irritating cough.
目的 研究无创通气(NIPPV)治疗对肾移植术后巨细胞病毒(CMV)肺炎患者的疗效。方法 1998年1月~2005年12月间入住中山大学附属第一医院内科重症监护病房(MICU)的78例肾移植术后CMV肺炎患者,根据是否接受无创通气治疗而分为非NIPPV组和NIPPV组,比较两组患者在接受有创机械通气比例、病死率、住院时间及并发症等方面的差异。对52例NIPPV组患者,比较无创通气治疗前后生命体征及血气分析指标的变化。结果 NIPPV组与非NIPPV组相比,接受有创机械通气比例(30.8% 比80.8%)、医院获得性肺炎发生率(32.7% 比61.5%)及病死率(30.8% 比57.7%)较低,两组比较均有显著性差异(P均lt;0.05);而住院时间、气压伤发生率无显著差异。NIPPV组患者无创通气治疗后患者呼吸频率有所减慢,动脉血pH值逐渐降低,PaCO2水平缓慢上升,PaO2、PaO2 /FiO2及SaO2明显升高,两组比较均有显著差异(P均lt;0.05)。而无创通气治疗前后心率、血压的变化则无明显规律。结论 NIPPV治疗能够改善肾移植术后CMV肺炎患者的低氧血症,缓解呼吸窘迫症状,降低有创机械通气治疗比例及医院获得性肺炎的发生率,从而降低病死率。用无创通气治疗巨细胞病毒肺炎值得在临床上推广使用。