west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHANG Chaolong" 2 results
  • Long-term outcomes of totally endoscopic minimally invasive mitral valve repair for Barlow’s disease

    ObjectiveTo examine the safety, efficacy and durability of totally endoscopic minimally invasive (TEMI) mitral valve repair in Barlow’s disease (BD). MethodsA retrospective study was performed on patients who underwent mitral valve repair for BD from January 2010 to June 2022 in the Guangdong Cardiovascular Institute. The patients were divided into a MS group and a TEMI group according to the surgery approaches. A comparison of the clinical data between the two groups was conducted. ResultsA total of 196 patients were enrolled, including 133 males and 63 females aged (43.8±14.9) years. There were 103 patients in the MS group and 93 patients in the TEMI group. No hospital death was observed. There was a higher percentage of artificial chordae implantation in the TEMI group compared to the MS group (P=0.020), but there was no statistical difference between the two groups in the other repair techniques (P>0.05). Although the total operation time between the two groups was not statistically different (P=0.265), the TEMI group had longer cardiopulmonary bypass time (P<0.001) and aortic clamp time (P<0.001), and shorter mechanical ventilation time (P=0.025) and postoperative hospitalization time (P<0.001). No statistical difference between the two groups in the adverse perioperative complications (P>0.05). The follow-up rate was 94.2% with a mean time of 0.2-12.4 (4.0±2.4) years. Two patients in the MS group died with non-cardiac reasons during the follow-up period. The 3-year, 5-year and 10-year survival rates of all patients were 99.2%, 99.2%, and 82.6%, respectively. Compared with the MS group, there was no statistical difference in the survival rate, recurrence rate of mitral regurgitation, reoperation rate of mitral valve or adverse cardiovascular and cerebrovascular events in the TEMI group (P>0.05). ConclusionTEMI approach is a safe, feasible and effective approach for BD with a satisfying long-term efficacy.

    Release date: Export PDF Favorites Scan
  • Development and performance testing of a novel transcatheter tricuspid valve interventional device

    Objective To develop a novel transcatheter tricuspid valve replacement device and test its performance. MethodsThe transcatheter tricuspid valve stent consisted of double-layer self-expanding nitinol stent, biotissue-derived bovine pericardial leaflets, and PTFE woven. The delivery system, mainly consisting of a handle control unit and a delivery sheath, was sent to the correct position via right atrium or jugular vein. The sheath had a visualization feature, and the handle control unit could realize the functions of stable release and partial recovery of the interventional valve. In addition, this study performed animal survival experiments on the basis of in vitro experiments. A large-white pig was used as the experimental animal. Cardiopulmonary bypass was established through median thoracotomy, then the right atrium was opened, and the interventional valve was released under direct vision without cardiac arrest. Approximately 1 month after interventional valve implantation, the maneuverability and stability of the interventional tricuspid device were evaluated by autopsy. ResultsThrough the animal experiment, the interventional valve was successfully released, and the anchoring was satisfactory. Postoperative transthoracic echocardiography showed that the interventional valve opened and closed well, the flow rate of tricuspid valve was 0.6 m/s, and there was no obvious tricuspid regurgitation. One month after the operation, we dissected the large-white pig and found the interventional valve was not deformed or displaced, the leaflets were well aligned, and there was thrombus attachment in the groove between the inner and outer layers of the interventional valve. ConclusionAnimal experiment shows that the novel device can stably and firmly attach to the tricuspid annulus, with good anchoring effect, and effectively reduce paravalvular leakage.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content