  • Interpretation of the section of congenital heart diseases in Annual Report on Cardiovascular Health and Diseases in China (2019)

    Congenital heart disease (CHD) is a birth defect with the highest incidence in China. In September 2020, Annual Report on Cardiovascular Health and Diseases in China (2019) was published by National Center for Cardiovascular Diseases. The present situation of prevention and treatment of CHD was briefly summarized in this report. In this paper, we presented the main opinions of Annual Report on Cardiovascular Health and Diseases in China (2019), supplied with relevant data, such as epidemiology, surgical treatment and interventional treatment of CHD, to further expand and explain this report.

    Release date:2021-04-25 09:57 Export PDF Favorites Scan
  • Application of novel wire system for echo-guiding percutaneous atrial septal defect closure

    ObjectiveTo evaluate the efficacy and safety of a novel wire for echo-guiding percutaneous atrial septal defect (ASD) closure.MethodsTwenty sheep were randomly divided into two groups, an experimental group and a control group (n=10 in each group). In both groups, an animal model of ASD was established by transthoracic balloon dilatation, and percutaneous closure of atrial septal defect was finished only by echography guiding. The total procedure time, passing time (time needed for the guide wire to enter the left atrium), frequency of delivery sheath dropping into right atrium, frequency of arrhythmias and rate of complications were compared between the two groups.ResultsASD model was uneventfully established in all animals. ASD devices were successfully implanted in all sheep. Compared with the control group, the experimental group had significantly less mean procedure time and mean passing time, lower frequency of guide wire dropping into right atrium and frequency of atrial and ventricular premature contractions, respectively (15.36±4.86 min vs. 25.82±7.85 min, 2.69±0.82 min vs. 5.58±3.34 min, 0% vs. 40.0%, 4.41±2.61 vs. 9.60±3.68, 0.75±0.36 vs. 1.34±0.68; all P<0.05) . Two groups did not have serious complications within postoperative one week.ConclusionThe novel wire system is not only safe and effective in the treatment of ASD occlusion, but also easy to operate.

    Release date:2019-01-23 02:58 Export PDF Favorites Scan
  • Current situation and prospect of interventional therapy for congenital heart disease in China

    Transcatheter intervention for congenital heart disease has been developed for 40 years in China, it has experienced the transition of learning to self-dependent innovation, and witnessed the intervention therapy system starting from scratch and gradually reaching the top level and gaining high achievements in the world scale. With the continuous development of interventional technology and devices, cutting-edge ideas and viewpoints are constantly discussed. This review summarized the development of intervention techniques and devices, hoping to provide some experience for the further development of transcatheter interventions for congenial heart disease.

    Release date: Export PDF Favorites Scan
  • Changes of ascending aortic diameter after transcatheter aortic valve replacement

    ObjectiveTo evaluate the changes of ascending aortic (AA) diameter after transcatheter aortic valve replacement (TAVR), and evaluate the safety and efficacy of TAVR in patients with AA dilation. MethodsWe retrospectively included 87 patients who underwent TAVR at our center from 2016 to 2019. These patients were divided into 2 groups based on the preoperative AA diameter. There were 17 patients in the AA diameter≥45 mm group (including 10 males, aged 74.4±5.6 years), and 70 patients in the AA diameter<45 mm group (including 39 males, aged 75.9±7.0 years). Results The baseline variables were similar between two groups (P>0.05). The overall device success rate was 97.7% (85/87). The median computed tomography (CT) follow-up time was 24.2±11.8 months in patients with AA diameter≥45 mm and 23.0±10.7 months in patients with AA diameter<45 mm, and the median annual dilation rate of AA were 0.36 mm/year and 0.00 mm/year, respectively. No statistical significance was observed between two groups (P>0.05). No adverse aortic events occurred during the follow-up period. ConclusionTAVR is safe and effective in patients with preoperative AA diameter≥45 mm, and the AA diameter remains stable after the procedure. Patients with preoperative AA diameter≥45 mm and AA diameter<45 mm have similar annual dilation rates.

    Release date: Export PDF Favorites Scan
  • Clinical results of ultrasound-guided thoracoscopic atrial septal defect closure

    Objective To analyze the safety and effectiveness of ultrasound-guided thoracoscopic atrial septal defect (ASD) closure. Methods We prospectively collected the clinical data of 12 patients with ASD treated by ultrasound-guided thoracoscopic ASD closure in Fuwai Hospital from January to September 2017. The characteristics of the patients' ASD and operation, operation safety and effectiveness, postoperative complications and follow-up results were analyzed. Results Among the 12 patients, 10 were successfully treated with ultrasound-guided thoracoscopic ASD closure. Two patients switched to ASD repair under thoracoscopy-assisted cardiopulmonary bypass. The size of the ASD was 17-40 (27.22±8.97) mm and the size of the occluder was 36 (30-42) mm. The average postoperative length of hospital stay was 6 days. There were no complications such as arrhythmia, bleeding and pericardial effusion after operation. The average follow-up was 6 (3-10) months after the operation. During the follow-up, no Ⅲ-degree conduction block, occluder dislocation, residual shunt or cardiac pericardial effusion was found. Conclusion Ultrasound-guided thoracoscopic ASD closure is a minimally invasive, safe and effective treatment. This technique provides a new minimally invasive surgical option for patients with large defect diameter and poor edge condition.

    Release date:2018-06-01 07:11 Export PDF Favorites Scan
  • Midterm outcome of percutaneous balloon aortic valvuloplasty guided by single echocardiography for congenital aortic stenosis

    Objective To analyze the midterm outcome of patients with congenital aortic stenosis undergoing percutaneous balloon aortic valvuloplasty (PBAV) by single echocardiographic guidance. Methods The clinical data of 12 patients with congenital aortic stenosis who underwent PBAV by single echocardiographic guidance at Fuwai Hospital from January 2016 to November 2017 were retrospectively analyzed. There were 7 males and 5 females with an average age of 18.27±15.30 years. The preoperative peak pressure gradient was 61.8–110.0 (80.30±24.50) mm Hg, and 50% of patients had aortic regurgitation. Results All patients successfully underwent PBAV. Aortic annulus diameter was 18.65±3.17 mm and balloon diameter was 17.62±3.77 mm, with balloon diameter to annulus diameter ratio of 0.92±0.07. The peak transaortic gradient was 16-51 (36.72±12.33) mm Hg immediately after procedure, which was significantly different from the preoperation (P=0.000). During the follow-up period, the peak transaortic gradient was 21-58 (37.06±13.52) mm Hg, and there was no significant difference between the follow-up and immediate postoperation (P=0.310). Immediately after procedure and during follow-up, 58% of patients had aortic regurgitation, which was not statistically different from the preoperation (P=0.682). Conclusion Systematic use of Doppler echocardiographic guidance for PBAV is feasible, and that it is associated with a high success rate and a very low complication rate.

    Release date:2018-09-25 04:15 Export PDF Favorites Scan
  • Percutaneous transcatheter closure of atrial septal defect guided by transthoracic echocardiography in outpatients

    ObjectiveTo assess the feasibility and safety of percutaneous transcatheter closure of atrial septal defect (ASD) guided by transthoracic echocardiography (TTE) in outpatients.MethodsFrom December 2016 to June 2018, 50 simple ASD patients underwent TTE-guided transcatheter closure in the outpatient operating room of our hospital (a TTE group) including 22 males and 28 females at the age of 16-48 (27.40±6.95) years. Fifty patients with simple ASD treated with the guidance of conventional fluoroscopy during the same period were treated as a control group, including 22 males and 28 females at the age of 15-48 (28.58±6.96) years. Both groups were re-examined by TTE during follow-up at 1 month, 3 months, 6 months and 1 year.ResultsThe mean age, body weight, the size of ASD and occluder and success rate had no statistical difference between the two groups (P>0.05). Compared with the control group, the TTE group had significantly lower mean operation time (P<0.01) and less cost (P<0.01) since patients need not to be hospitalized. No related complications were found in the TTE group during follow-up.ConclusionPercutaneous transcatheter closure of ASD guided by TTE appears safe and effective for outpatients, and can significantly reduce the cost.

    Release date:2020-01-17 05:18 Export PDF Favorites Scan
  • Contrast-zero ultrasound-guided transcatheter aortic valve replacement: A case report

    Conventional transcatheter aortic valve replacement is normally recommended with transthoracic echocardiography, and contrast agent mediated fluoroscopy under anesthesia to guide a better implantation of the transcatheter valve. However, iodine-containing contrast agent possibly damages the patient’s kidney, and even induces the acute kidney injury. We reported a 75-year-old patient diagnosed with severe aortic valve stenosis, moderate regurgitation, and chronic renal failure. We performed the aortic valve replacement under the guidance of fluoroscopy and transesophageal ultrasound without contrast agent. Seven days after surgery, the patient recovered well and discharged with alleviated aortic stenosis and fixed transcatheter aortic valve.

    Release date: Export PDF Favorites Scan
  • Reconstruction and analysis of K-Clip surgery process based on finite element method

    Objective To investigate the effects of different types of tricuspid regurgitation, implantation positions, and device models on the treatment outcomes of K-Clip for tricuspid regurgitation using numerical simulations. Methods Three-dimensional reconstruction of the heart model was performed based on CT images. Two different regurgitation orifices were obtained by modifying the standard parameterized tricuspid valve leaflets and chordae tendineae. The effects of different K-Clip models at different implantation positions (posterior leaflet midpoint, anterior-posterior commissure, anterior leaflet midpoint, posterior septal commissure) were simulated using commercial explicit dynamics software Ls-Dyna. Conclusion For the two types of regurgitation in this study, clipping at the posterior leaflet midpoint resulted in a better reduction of the regurgitation orifice (up to 75% reduction in area). Higher clamping forces were required for implantation at the anterior leaflet midpoint and posterior septal commissure, which was unfavorable for the smooth closure of the clipping components. There was no statistical difference in the treatment outcomes between the 18T and 16T K-Clip components, and the 16T component required less clamping force. Therefore, the use of the 16T K-Clip component is recommended.

    Release date: Export PDF Favorites Scan
  • Echo-guiding percutaneous aortic stent implantation for coarctation of the aortic: A case report

    Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.

    Release date: Export PDF Favorites Scan