west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHANG Gejun" 6 results
  • The newly designed transcatheter edge-to-edge mitral repair system in treating patients with severe mitral regurgitation: Two cases report

    Mitral regurgitation (MR) is the most common valvular heart disease, however, majority of patients are not suitable for open heart surgery due to comorbidity such as organ and heart dysfunction. Transcatheter edge-to-edge mitral valve repair has become an effective treatment option for high-risk patients with MR. Two patients were enrolled in this study inlcuding one 60-year degenerative mitral regurgitation patient and one 72-year functional mitral regurgitation patient. Transcatheter repair procedure was successfully done for the two patients without postoperative complication.

    Release date: Export PDF Favorites Scan
  • Preliminary analysis of subclinical leaflet thrombosis after percutaneous aortic valve replacement with balloon dilation

    ObjectiveTo analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.

    Release date: Export PDF Favorites Scan
  • Early outcome of balloon-expandable valves in the treatment of severe aortic stenosis: A single-center study

    Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. ConclusionThe use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.

    Release date: Export PDF Favorites Scan
  • Percutaneous transcatheter closure of atrial septal defect guided by transthoracic echocardiography in outpatients

    ObjectiveTo assess the feasibility and safety of percutaneous transcatheter closure of atrial septal defect (ASD) guided by transthoracic echocardiography (TTE) in outpatients.MethodsFrom December 2016 to June 2018, 50 simple ASD patients underwent TTE-guided transcatheter closure in the outpatient operating room of our hospital (a TTE group) including 22 males and 28 females at the age of 16-48 (27.40±6.95) years. Fifty patients with simple ASD treated with the guidance of conventional fluoroscopy during the same period were treated as a control group, including 22 males and 28 females at the age of 15-48 (28.58±6.96) years. Both groups were re-examined by TTE during follow-up at 1 month, 3 months, 6 months and 1 year.ResultsThe mean age, body weight, the size of ASD and occluder and success rate had no statistical difference between the two groups (P>0.05). Compared with the control group, the TTE group had significantly lower mean operation time (P<0.01) and less cost (P<0.01) since patients need not to be hospitalized. No related complications were found in the TTE group during follow-up.ConclusionPercutaneous transcatheter closure of ASD guided by TTE appears safe and effective for outpatients, and can significantly reduce the cost.

    Release date:2020-01-17 05:18 Export PDF Favorites Scan
  • Primary practice of transcatheter edge-to-edge repair for mitral regurgitation: Early results of MitraClip in multiple centers

    ObjectiveTo investigate the early clinical results of MitraClip system in domestic patients. Methods We retrospectively analyzed the clinical data of 36 patients who underwent transcatheter edge-to-edge repair procedure using MitraClip system in Beijing Fuwai Hospital, Shenzhen Fuwai Hospital and Fuwai Yunnan Cardiovascular Hospital between January and June 2021. There were 24 males and 12 females, with a median age of 70 (47-86) years. Ten (27.8%) patients had 3+ mitral regurgitation (MR) and 26 (72.2%) patients had 4+ MR preoperatively. ResultsAll procedures were successfully performed. The reduction in MR was 2+ at least immediately after surgery, and 91.7% of patients had MR≤2+ at 3 days postoperatively. There was no statistical difference in left ventricular ejection fraction change postoperatively. Forward velocity and peak gradient of mitral valve were increased after the procedure. Mean gradient of mitral valve were increased at 3 days postoperatively than immediately after surgery (P<0.001). Two patients had acute pericardial effusion intraoperatively, and received pericardial puncture and drainage immediately. ConclusionMitraClip system has been applied well in domestic patients and can significantly improve MR. This sutdy has a good consistency with foreign studies, and the early results are satisfactory.

    Release date: Export PDF Favorites Scan
  • Clinical efficacy analysis of different interventional approaches for patent ductus arteriosus in children (≤7 years)

    ObjectiveTo explore the safety and effectiveness of different interventional approaches for the treatment of patent ductus arteriosus (PDA) in children.MethodsThe children (≤7 years) who underwent interventional treatment for PDA from 2019 to 2020 in our hospital were retrospectively included. The patients were divided into 3 groups according to the procedures: a conventional arteriovenous approach group, a simple venous approach group, and a retrograde femoral artery approach group. The clinical efficacy of the patients was compared. Results A total of 220 patients were included. There were 78 males and 142 females, with an average age of 3.21±1.73 years, weight of 14.99±5.35 kg, and height of 96.19±15.77 cm. The average diameter of the PDA was 3.35±1.34 mm. A total of 85 patients received a conventional arteriovenous approach, 104 patients received a simple venous approach, and 31 patients received a retrograde femoral artery approach. The diameter of PDA in the retrograde femoral artery group was smaller than that in the other two groups (3.44±1.43 mm vs. 1.99±0.55 mm; 3.69±1.17 mm vs. 1.99±0.55 mm, P<0.001); the contrast medium usage [40 (30, 50) mL vs. 20 (20, 30) mL; 35 (25, 50) mL vs. 20 (20, 30) mL, P≤0.001] and operation time [32 (26, 44) min vs. 25 (23, 30) min; 29 (25, 38) min vs. 25 (23, 30) min, P<0.05] in the simple venous approach group were significantly less or shorter than those in the other two groups; the length of hospital stay of the conventional arteriovenous group was longer than that in the other two groups [3 (3, 5) d vs. 4 (3, 6) d; 4 (3, 5) d vs. 4 (3, 6) d, P<0.05]. There was no significant difference in postoperative complications.ConclusionIt is safe and effective to close PDA through simple venous approach. The retrograde femoral artery approach has the advantage of simplifying the surgical procedure for PDA with small diameters.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content