west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHANG Haowei" 5 results
  • Model construction and software design of computed tomography radiation system based on visualization

    The Monte Carlo N-Particle (MCNP) is often used to calculate the radiation dose during computed tomography (CT) scans. However, the physical calculation process of the model is complicated, the input file structure of the program is complex, and the three-dimensional (3D) display of the geometric model is not supported, so that the researchers cannot establish an accurate CT radiation system model, which affects the accuracy of the dose calculation results. Aiming at these two problems, this study designed a software that visualized CT modeling and automatically generated input files. In terms of model calculation, the theoretical basis was based on the integration of CT modeling improvement schemes of major researchers. For 3D model visualization, LabVIEW was used as the new development platform, constructive solid geometry (CSG) was used as the algorithm principle, and the introduction of editing of MCNP input files was used to visualize CT geometry modeling. Compared with a CT model established by a recent study, the root mean square error between the results simulated by this visual CT modeling software and the actual measurement was smaller. In conclusion, the proposed CT visualization modeling software can not only help researchers to obtain an accurate CT radiation system model, but also provide a new research idea for the geometric modeling visualization method of MCNP.

    Release date: Export PDF Favorites Scan
  • A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications

    In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.

    Release date: Export PDF Favorites Scan
  • Study on the method of polysomnography sleep stage staging based on attention mechanism and bidirectional gate recurrent unit

    Polysomnography (PSG) monitoring is an important method for clinical diagnosis of diseases such as insomnia, apnea and so on. In order to solve the problem of time-consuming and energy-consuming sleep stage staging of sleep disorder patients using manual frame-by-frame visual judgment PSG, this study proposed a deep learning algorithm model combining convolutional neural networks (CNN) and bidirectional gate recurrent neural networks (Bi GRU). A dynamic sparse self-attention mechanism was designed to solve the problem that gated recurrent neural networks (GRU) is difficult to obtain accurate vector representation of long-distance information. This study collected 143 overnight PSG data of patients from Shanghai Mental Health Center with sleep disorders, which were combined with 153 overnight PSG data of patients from the open-source dataset, and selected 9 electrophysiological channel signals including 6 electroencephalogram (EEG) signal channels, 2 electrooculogram (EOG) signal channels and a single mandibular electromyogram (EMG) signal channel. These data were used for model training, testing and evaluation. After cross validation, the accuracy was (84.0±2.0)%, and Cohen's kappa value was 0.77±0.50. It showed better performance than the Cohen's kappa value of physician score of 0.75±0.11. The experimental results show that the algorithm model in this paper has a high staging effect in different populations and is widely applicable. It is of great significance to assist clinicians in rapid and large-scale PSG sleep automatic staging.

    Release date: Export PDF Favorites Scan
  • Automatic sleep staging model based on single channel electroencephalogram signal

    Sleep staging is the basis for solving sleep problems. There’s an upper limit for the classification accuracy of sleep staging models based on single-channel electroencephalogram (EEG) data and features. To address this problem, this paper proposed an automatic sleep staging model that mixes deep convolutional neural network (DCNN) and bi-directional long short-term memory network (BiLSTM). The model used DCNN to automatically learn the time-frequency domain features of EEG signals, and used BiLSTM to extract the temporal features between the data, fully exploiting the feature information contained in the data to improve the accuracy of automatic sleep staging. At the same time, noise reduction techniques and adaptive synthetic sampling were used to reduce the impact of signal noise and unbalanced data sets on model performance. In this paper, experiments were conducted using the Sleep-European Data Format Database Expanded and the Shanghai Mental Health Center Sleep Database, and achieved an overall accuracy rate of 86.9% and 88.9% respectively. When compared with the basic network model, all the experimental results outperformed the basic network, further demonstrating the validity of this paper's model, which can provide a reference for the construction of a home sleep monitoring system based on single-channel EEG signals.

    Release date: Export PDF Favorites Scan
  • Biomechanical analysis of Magic screw fixation for acetabular posterior column fracture

    This study aims to analyze the biomechanical stability of Magic screw in the treatment of acetabular posterior column fractures by finite element analysis. A three-dimensional finite element model of the pelvis was established based on the computed tomography (CT) and magnetic resonance imaging (MRI) data of a volunteer and its effectiveness was verified. Then, the posterior column fracture model of the acetabulum was generated. The biomechanical stability of the four internal fixation models was compared. The 500 N force was applied to the upper surface of the sacrum to simulate human gravity. The maximum implant stresses of retrograde screw fixation, single-plate fixation, double-plate fixation and Magic screw fixation model in standing and sitting position were as follows: 114.10, 113.40 MPa; 58.93, 55.72 MPa; 58.76, 47.47 MPa; and 24.36, 27.50 MPa, respectively. The maximum stresses at the fracture end were as follows: 72.71, 70.51 MPa; 48.18, 22.80 MPa; 52.38, 27.14 MPa; and 34.05, 30.78 MPa, respectively. The fracture end displacement of the retrograde tension screw fixation model was the largest in both states, and the Magic screw had the smallest displacement variation in the standing state, but it was significantly higher than the two plate fixations in the sitting state. Magic screw can satisfy the biomechanical stability of posterior column fracture. Compared with traditional fixations, Magic screw has the advantages of more uniform stress distribution and less stress, and should be recommended.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content