west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHANG Jingnan" 2 results
  • Preliminary analysis of subclinical leaflet thrombosis after percutaneous aortic valve replacement with balloon dilation

    ObjectiveTo analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.

    Release date: Export PDF Favorites Scan
  • Early outcome of balloon-expandable valves in the treatment of severe aortic stenosis: A single-center study

    Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. ConclusionThe use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content