west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHAO Junfei" 8 results
  • Sutureless technique use in the surgery for total anomalous pulmonary venous connection in neonates

    Objective To analyze the sutureless technique use in the surgical repair for total anomalous pulmonary venous connection in neonates. Methods Between September 2002 and December 2015, 71 consecutive neonates with supracardiac or infracardiac type total anomalous pulmonary venous connection who underwent surgical repair in our institute were included in this study. There were 57 males and 14 females at median age of 8 (1, 29) d. And the median body weight was 3.3 (2.1, 4.7) kg. There were 45 patients (63.4%) with supracardiac, 26 patients (36.6%) with infracardiac. Patients were divided into two groups: a conventional technique group (29 patients) and a sutureless technique group (42 patients). To control for potential differences in the characteristics of patients between the sutureless technique group and the conventional technique group, the method of propensity-score matching was used. Results Basic characteristics of patients after propensity-score were not different.There were 11 operative deaths (15.5%), 7 late deaths (96.%), total 18 deaths (25.4%). The mortality was 58.6% (17/29) in the conventional technique group, 2.4% (1/42) in the sutureless technique group (P=0.000). Kaplan-Meier survival curve showed a difference in mortality between the two groups (P=0.005). The patients were followed up for 25.5 (1.0-13.0) months.Postoperative anastomotic or pulmonary vein stenosis occurred in 12 patients, 8 of them died at a higher mortality than that of the patients with smooth anastomosis [66.7% (8/12) vs. 16.9% (10/59), P=0.001]. Conclusion The patients who have postoperative anastomotic or pulmonary vein stenosis have higher mortality. Compared with conventional technique, sutureless technique can dramatically decrease the incidence of postoperative anastomotic or pulmonary vein stenosis and the mortality of surgical repair for total anomalous pulmonary venous connection in neonates.

    Release date:2017-09-04 11:20 Export PDF Favorites Scan
  • Proportion of pulmonary valve annulus: A new predictive index for transannular patch in repair of tetralogy of Fallot

    ObjectiveTo investigate if the ratio of pulmonary valve annulus, which is the proportion of pulmonary valvular annulus size to total size of aortic valvular annulus and pulmonary valvular annulus, can better guide the choice of surgical approach than the value of z.MethodsA retrospective analysis was made for 254 patients who underwent total correction of tetralogy of Fallot in Guangdong General Hospital between January 2016 and January 2018. There were 154 males and 100 females with an average age of 14.60±18.76 years. The patients were categorized into two groups, a transannular patch group (TAP, n=164) and a non-TAP group (n=90). The sizes of pulmonary and aortic valvular annulus were evaluated in each group, and the cutoff value of proportion of pulmonary valvular annulus for TAP was calculated.ResultsBoth proportion of pulmonary valvular annulus and z-scores were smaller in the TAP group than those in the non-TAP group (0.29±0.06 vs. 0.36±0.06, P<0.001; –4.04±2.13 vs. –2.06±1.84, P<0.001, respectively). In receiver operating characteristics analyses, proportion of pulmonary valvular annulus and the z-score cutoff values were 0.353 (area under the curve 0.781, 95%CI 0.725–0.831) and –2.13 (area under the curve 0.766, 95%CI 0.709–0.817), respectively, demonstrating that the proportion of pulmonary valvular annulus was a more powerful diagnostic tool as a predictor of TAP.ConclusionOur results suggest that the proportion of pulmonary valvular annulus is an effective predictor for TAP and can be easily applied to clinical practice.

    Release date:2019-03-29 01:35 Export PDF Favorites Scan
  • Application and evaluation of modified pericardial oblique sinus approach in total anomalous pulmonary venous connection in neonates

    Objective To analyze the use of modified pericardial oblique sinus approach in surgical repair for total anomalous pulmonary venous connection in neonates. Methods Between May 2005 and December 2015, 67 consecutive neonates with supracardiac or infracardiac type total anomalous pulmonary venous connection who underwent surgical repair in our institute were included in this study. The patients are divided into three groups according to the different approaches including a sulcus approach group (6 patients), a superior approach group (14 patients), and a modified pericardial oblique sinus approach group (47 patients). There were 53 males and 14 females at median age of 12.5 (7.0, 20.5) d. Results The time of cardiopulmonary bypass [88 (80.0, 107.0) min vs. 135 (121.0, 157.0) min, P<0.05] and aortic cross clamping of the modified pericardial oblique sinus approach group was significantly shorter than that of the sulcus approach group [45 (39.0, 53.0) min vs. 80 (73.0, 85.0) min, P<0.05]. Perioperative mortality (2.1% vs. 28.6%, P<0.05) was significantly lower in the modified pericardial oblique sinus approach group than that in the superior approach group. The long-term mortality (4.3% vs. 60.0%, P<0.05) was significantly lower in the modified pericardial oblique sinus approach group than that in the sulcus approach group or the superior approach group . The rate of pulmonary venous stenosis was significantly lower in the modified pericardial oblique sinus approach group than that in the sulcus approach group (2.1% vs. 50.0%, P<0.05) or superior approach group (2.1% vs. 35.7%, P<0.05). Conclusions In surgical correction of neonatal supracardiac and infracardiac total anomalous pulmonary venous, compared with the traditional surgical approach, the modified pericardial oblique sinus pathway can provide excellent surgical space and has a good surgical prognosis.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Eearly outcomes of totally thoracoscopic minimally invasive aortic valve and double valve replacement

    ObjectiveTo summarize the early outcomes of totally thoracoscopic minimally invasive aortic valve replacement (AVR) and double valve replacement (DVR).MethodsThe clinical data of patients who underwent totally thoracoscopic minimally invasive AVR or DVR in Guangdong Provincial People’s Hospital from April 2020 to January 2021 were retrospectively analyzed. The patients were divided into an AVR group and a DVR group according to the surgical method, and the clinical data of the two groups were compared.ResultsFinally 22 patients were enrolled, including 14 males and 8 females with an average age of 50.0±11.2 years at operation. Eight patients were degenerative disease, 8 were rheumatic heart disease combined with valvular disease, and 6 were bicuspid aortic valve. Out of the 22 patients, 16 underwent AVR alone, and 6 underwent DVR. All patients completed the operation successfully, and there was no death. Perivalvular leakage during surgery occurred in 2 patients. The average cardiopulmonary bypass time was 187.0±39.9 minutes, and aortic cross-clamping time was 117.0 (99.0, 158.0) minutes. Duration of mechanical ventilation and intensive care unit stay was 9.5 (4.8, 18.3) hours and 41.0 (34.0, 64.0) hours, respectively. The volume of chest drainage at the first 24 hours after surgery was 214.0±124.6 mL, and the postoperative hospital stay was 5.5 (4.0, 8.3) days. The cardiopulmonary bypass time and aortic cross-clamping time in the DVR group were longer than those in the AVR group, and the volume of chest drainage at 24 hours after surgery was more than that in the AVR group, with a statistical difference (P<0.05). Echocardiography before hospital discharge showed paravalvular leakage in 1 patient. There was no death during follow-up of 5.9±3.0 months. ConclusionThe early outcome of totally thoracoscopic minimally invasive AVR and DVR is satisfactory, and the approach of surgery is worth exploring.

    Release date: Export PDF Favorites Scan
  • The value of right atrial myocardial fibrosis in evaluating the prognosis of isolated tricuspid valve surgery after left heart valve surgery

    ObjectiveTo investigate the predictive value of right atrial myocardial fibrosis in the prognosis of isolated tricuspid regurgitation surgery after left heart valve surgery. MethodsThe patients who underwent tricuspid valvuloplasty by the same operator in Guangdong Provincial People's Hospital from April 2016 to August 2021 due to long-term isolated severe tricuspid regurgitation after left heart valve surgery were included in the study. According to the degree of right atrial myocardial fibrosis, the patients were divided into three groups: a mild group, a moderate group, and a severe group. The clinical data of these patients were compared and analyzed. ResultsA total of 75 patients were enrolled, including 16 males and 59 females with an average age of 57.0±8.4 years. There were 30 patients in the mild group, 29 patients in the moderate group and 16 patients in the severe group. In terms of the preoperative data, there were statistical differences in cardiac function grade, right atrial diameter, tricuspid incompetence area among the three groups (P<0.05). In terms of the postoperative data, there were statistical differences among the three groups in the cardiopulmonary bypass time, mechanical ventilation time, ICU monitoring time, complication rate and mortality (P<0.05). Further pairwise comparison showed that, compared with the mild group, the severe group had longer mechanical ventilation time (P=0.024), longer ICU monitoring time (P=0.003) and higher incidence of postoperative complications (P=0.024), while the moderate group had no statistical difference in all aspects (P>0.05); compared with the moderate group, the severe group had longer ICU monitoring time (P=0.021) and higher incidence of complications (P=0.006). ConclusionThe early outcome of tricuspid valvuloplasty in patients with isolated tricuspid regurgitation after left heart valve surgery with severe right atrial myocardial fibrosis is worse than that in the patients with mild and moderate fibrosis, suggesting that the degree of myocardial fibrosis in the right atrium can be a predictor of the effect of tricuspid regurgitation surgery and a judgement indicator of the surgery timing.

    Release date: Export PDF Favorites Scan
  • Totally endoscopic transmitral myectomy and traditional thoracotomy for hypertrophic obstructive cardiomyopathy: A propensity score matching analysis

    ObjectiveTo investigate the effectiveness and safety of totally endoscopic transmitral myectomy (TETM) for hypertrophic obstructive cardiomyopathy (HOCM), comparing with traditional sternotomy modified Morrow procedure (SMMP).MethodsThirty-eight patients with HOCM who needed surgical intervention were selected from our hospital in 2019, including 14 males and 24 females, with an average age of 56 (44-68) years. According to the operation method, they were divided into a TETM group (n=18) and a SMMP group (n=20). Appropriate patients were screened by propensity matching scores. Finally, the clinical data of two matched groups were compared and analyzed.ResultsThere was no death, septal perforation, residual left ventricular outflow tract obstruction or third degree atrioventricular block in either group. After propensity score matching, there was no statistical difference between the two groups in the ICU length of stay (41.5±5.0 h vs. 53.0±24.0 h, P=0.620), ventilation time (19.5±9.2 h vs. 38.0±24.0 h, P=0.463), cardiopulmonary bypass time (190.7±45.6 min vs. 156.0±70.7 min, P=0.627), aortic cross-clamp time (100.1±25.3 min vs. 94.5±57.3 min, P =0.915), left ventricular outflow tract gradient (17.0±1.4 mm Hg vs. 5.0±0.5 mm Hg, P=0.053), left atrial anterior and posterior diameter (37.0±1.3 mm vs. 40.0±0.7 mm, P=0.090), interventricular septum thickness (12.5±0.7 mm vs. 13.0±1.4 mm, P=0.712), left ventricular posterior wall thickness (10.0±1.4 mm vs. 10.5±2.1 mm, P=0.811), left ventricular end-diastolic diameter (43.5±3.5 mm vs. 46.0±4.2 mm, P=0.589), and mitral regurgitation (1.0±0.2 vs. 0.7±0.5, P=0.500). The follow-up time was 6±3 months, and no death occurred. In the TETM group, one patient underwent mitral valvuloplasty again three months after surgery because of a tear in the A3 region of mitral valve..ConclusionTETM is a safe and effective procedure that can well expose the interventricular septum at the basal & middle obstruction site and effectively eliminate the mitral regurgitation associated with systolic anterior motion syndrome caused by left ventricular outflow tract obstruction.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Early outcomes of self-expanding interventional pulmonary valve in transthoracic implantation: A prospective clinical study

    ObjectiveTo evaluate early outcomes of transthoracic pulmonary valve implantation for the treatment of moderate and severe pulmonary regurgitation by using homemade self-expanding valve (SalusTM). MethodsPatients with severe pulmonary regurgitation who underwent transthoracic pulmonary valve implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to November 25, 2022 were prospectively enrolled. The early postoperative complications and improvement of valve and heart function were summarized and analyzed. ResultsA total of 25 patients were enrolled, including 16 males and 9 females, with an average age of 24.5±1.5 years and an average weight of 57.0±3.0 kg. The mean systolic diameters of the bifurcation near the main pulmonary artery, the stenosis of the middle segment of the aorta and near the valve of the right ventricular outflow tract of the patients were 31.8±7.4 mm, 30.6±5.9 mm and 38.4±8.0 mm, respectively. All patients were successfully implanted with valves, and there were no serious complications such as death, coronary compression, stent fracture, valve displacement and infective endocarditis in the early postoperative period. The indexed left atrial longitudinal diameter, indexed right atrial longitudinal diameter, and indexed right ventricular outflow tract anteroposterior diameter decreased significantly after the operation. The degree of tricuspid and pulmonary valve regurgitation and the indexed regurgitation area decreased significantly. The above differences were statistically significant (P<0.05). ConclusionThe early outcomes of transthoracic pulmonary valve implantation with homemade self-expanding pulmonary valve (SalusTM) in the treatment of severe pulmonary regurgitation is relatively good, and the long-term outcomes need to be verified by the long-term follow-up studies with large samples.

    Release date: Export PDF Favorites Scan
  • Development and performance testing of a novel transcatheter tricuspid valve interventional device

    Objective To develop a novel transcatheter tricuspid valve replacement device and test its performance. MethodsThe transcatheter tricuspid valve stent consisted of double-layer self-expanding nitinol stent, biotissue-derived bovine pericardial leaflets, and PTFE woven. The delivery system, mainly consisting of a handle control unit and a delivery sheath, was sent to the correct position via right atrium or jugular vein. The sheath had a visualization feature, and the handle control unit could realize the functions of stable release and partial recovery of the interventional valve. In addition, this study performed animal survival experiments on the basis of in vitro experiments. A large-white pig was used as the experimental animal. Cardiopulmonary bypass was established through median thoracotomy, then the right atrium was opened, and the interventional valve was released under direct vision without cardiac arrest. Approximately 1 month after interventional valve implantation, the maneuverability and stability of the interventional tricuspid device were evaluated by autopsy. ResultsThrough the animal experiment, the interventional valve was successfully released, and the anchoring was satisfactory. Postoperative transthoracic echocardiography showed that the interventional valve opened and closed well, the flow rate of tricuspid valve was 0.6 m/s, and there was no obvious tricuspid regurgitation. One month after the operation, we dissected the large-white pig and found the interventional valve was not deformed or displaced, the leaflets were well aligned, and there was thrombus attachment in the groove between the inner and outer layers of the interventional valve. ConclusionAnimal experiment shows that the novel device can stably and firmly attach to the tricuspid annulus, with good anchoring effect, and effectively reduce paravalvular leakage.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content