find Author "ZHENGQin" 2 results
  • Research on the Application of UF-1000i Urine Sediment Analyzer in Rapid Urinary Tract Infection Screening by Receiver Operator Characteristic Curve

    ObjectiveTo investigate the feasibility of quantitative detection of WBC count and bacteria count with UF-1000i urinary sediment analyzer in rapid screening for urinary tract infection by receiver operator characteristic (ROC) curve. MethodsFrom August to December 2013, we used quantitative bacterial culture and UF-1000i automatic urine sediment analyzer respectively to examine asepsis urine specimens of 218 patients with suspected urinary tract infection. Among them, there were 95 males and 123 females, with an average age of 54.7 years old. ResultsAmong the 218 urinary samples, 65 were culture positive specimens. With positive urine culture as the gold standard for making ROC curve, the area under ROC curve for WBC count and bacterial numbers by UF-1000i urine sediment analyzer were respectively 0.839 and 0.894. The cut-off values of Youden index for optimal WBC cell count and bacterial count were ≥31.0/μL and 38.8/μL, respectively. When the above numbers were used as cut-off values, the WBC count sensitivity and specificity were 78.3% and 80.4%, the positive likelihood ratio was 3.99, and the negative likelihood ratio was 1.11. And the bacterial count sensitivity and specificity were 84.3% and 80.6%, the positive likelihood ratio was 4.30, and the negative likelihood ratio was 0.80. ConclusionUsing white blood cell count ≥31/μL and bacterial count ≥38.8/μL detected by UF-1000i urine sediment analyzer as the cut off values of noninvasive screening indexes has a very important value in screening for urinary tract infection in the early stage, determining whether there is a need for urine culture, and guiding clinical rational application of antibiotics

    Release date: Export PDF Favorites Scan
  • The Performance Evaluation of Sysmex-XN Automatic Hematology Analyzer in Complete Blood Count

    ObjectiveTo evaluate the complete blood count performance quality of Sysmex-XN automatic hematology analyzer. MethodsWe investigated the precision rate, residual contamination rate, analytic linearity range, and background counting of Sysmex-XN-B3 analyzer. ResultsThe inner and inter-group precision test showed that the inaccuracy of the analyzer was lower than the allowable standard of 1/4 (CLIA'88). The highest level of residual contamination rate was 0.12%, lower than the standard of manufacturer (≤1%). Linearity evaluation showed that the white blood cell count analytic linear range was from 0.51×109/L to 393.40×109/L, the red blood cell count analytic linear range was from 0.51×1012/L to 8.15×1012/L, the hemoglobin analytic linear range from 15.0 g/L to 244.5 g/L, and the platelet count analytic linear range was from 3.0×109/L to 2 072.5×109/L. Background counting was also lower than the standard of manufacturer. Comparison between the two different series of analyzers showed that the inaccuracy rate of Sysmex-XN-B3 was not only lower than the standard of National Center for Clinical Laboratories, but also lower than the standard of 1/2 (CLIA'88). ConclusionSysmex-XN automatic hematology analyzer has a high performance in capability evaluation. It is an excellent tool for routine hematologic blood examination.

    Release date: Export PDF Favorites Scan