west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHONG Zeli" 12 results
  • Effectiveness comparison between minimally invasive surgery and traditional open reduction internal fixation in treatment of unstable distal radial fractures

    ObjectiveTo compare the effectiveness of minimally invasive percutaneous internal fixation and traditional open reduction via Henry approach and internal fixation in the treatment of unstable distal radial fractures.MethodsFifty-six patients with unstable distal radial fractures that met the selection criteria between October 2013 and December 2014 were randomly divided into minimally invasive group (26 cases) and traditional group (30 cases). They were treated with oblique T-shaped locking plate internal fixation via minimally invasive percutaneous approach or traditional Henry approach. There was no significant difference in gender, age, side, causes of injury, fracture classification, and time from injury to operation between 2 groups (P>0.05). The length of incision, operation time, intraoperative blood loss, hospitalization time, and fracture healing time were recorded in 2 groups. The difference of the length of the radial styloid process, the volar tilting angle, and the ulnar inclining angle between at 3 months postoperatively and preoperation were compared between 2 groups. The visual analogue scale (VAS) score, the percentage of the lateral wrist flexion and extension range, forearm rotation, and the hand grip strength (recorded as FS%, FR%, and HG% , respectively) were compared between 2 groups at 4 weeks and 3 months postoperatively. The wrist function was evaluated through the disability of arm-shoulder-hand (DASH) scores at 3 months postoperatively.ResultsThe length of incision, operation time, intraoperative blood loss, and hospitalization time in minimally invasive group were significantly less than those in traditional group (P<0.05). The incisions of 2 groups were all achieved primary healing. All patients were followed up 10-16 months (mean, 12.6 months). There was no radial artery injury, screw too long, or screw entering the joint space. In minimally invasive group, 1 patient had the symptoms of median nerve irritation after operation, and recovered completely at 1 month; in traditional group, there were 2 cases of tendon irritation after operation. There was no significant difference in the fracture healing time, the difference of the length of the radial styloid process, the volar tilting angle, and the ulnar inclining angle between at 3 months postoperatively and preoperation between 2 groups (P>0.05). At 4 weeks after operation, the VAS score in minimally invasive group was significantly less than that in traditional group, and the FS%, FR%, and HG% were significantly higher than those in traditional group (P<0.05). There was no significant difference in above indicators between 2 groups at 3 months after operation (P>0.05). The DASH score in minimally invasive group was significantly less than that in traditional group at 3 months after operation (t=–5.308, P=0.000). The patient’s aesthetic evaluation of postoperative wound in minimally invasive group was better than in traditional group.ConclusionFor treatment of unstable distal radial fractures, the metacarpal minimally invasive internal fixation has the advantages of smaller wound, incisional concealment, and quicker recovery of wrist joint.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Imaging study of “shell” phenomenon of thoracolumbar fractures after posterior reduction

    Objective To analyze the imaging characteristics of vertebral " shell” phenomenon of thoracolumbar fractures after posterior reduction and to explore the relationship between vertebral " shell” and fracture healing. Methods Between January 2013 and December 2015, the clinical data of 116 patients with thoracolumbar fractures treated with posterior pedicle screw-rod system reduction and internal fixation were analyzed retrospectively. There were 72 males and 44 females, aged 22-66 years (mean, 43 years). Injury causes were traffic accident in 24 cases, falling from height in 54 cases, bruise in 38 cases. Fracture segment located at T11 in 5 cases, T12 in 38 cases, L1 in 52 cases, L2 in 21 cases. There were 51 cases of compressive fracture and 65 cases of burst fracture. The sagittal Cobb angle ranged from 8 to 27°, with an average of 15°. Degree of preoperative spinal compression ranged from 20% to 75%, with an average of 44%. Bone density measurement showed that normal bone mass in 30 cases, bone loss in 40 cases, osteoporosis in 41 cases, and severe osteoporosis in 5 cases. The number, pathological characteristics, and imaging regularity of the vertebral " shell” phenomenon were observed and analyzed by logistic regression. Results All patients were followed up 11-18 months with an average of 13 months. A total of 72 cases of vertebral " shell” phenomenon mainly located in the vertebral anterior column and the end plate near the weak area (54/72, 75.0%). Most of them were in the irregular shape (50/72, 69.5%). The vertebral fracture line was related to the shape of the vertebral body and the displacement of the vertebral body after reduction. The outcome of the " shell” can be divided into disappeared type, reduced type, and collapse type, the volume of vertebral " shell” and its outcome were the risk factors for vertebral fracture healing. Conclusion The incidence of vertebral " shell” and nonuion of thoracolumbar fractures after posterior reduction are high. The main influencing factors are vertebral " shell” outcome and size.

    Release date:2017-08-03 03:46 Export PDF Favorites Scan
  • Application of thin CT angiography of pedicle sagittal plane of axis for preoperative evaluation of pedicle screw placement procedure

    ObjectiveTo explore the application value of thin CT angiography (CTA) of pedicle sagittal plane of axis for preoperative evaluation planning pedicle screw placement.MethodsBetween February 2016 and August 2017, 34 patients (68 pedicles) who underwent thin CTA scan before posterior axial surgery were retrospectively analyzed. The vertebral artery development was statistically analyzed. The continuous layers of transverse process hole pedicle height more than or equal to 4 mm (f) were measured and read. The axial fixation methods, clinical manifestations of vertebral artery and spinal cord injury and the bone union of fractures or implants were recorded. Postoperative results of pedicle screws were evaluated by CT scan.ResultsThe right sides of 8 cases and the left sides of 18 cases were dominant vertebral arteries, and equilibrium was reached in 8 cases; f>9 layers were found in 16 pedicles,f=9 layers in 27 pedicles, f=8 layers in 17 pedicles, and f<8 layers in 8 pedicles. The 43 pedicles off≥9 layers used pedicle screw fixation; in the 17 pedicles of f=8 layers, 16 used pedicle screw fixation, and the other one used laminar screw fixation; in the 8 pedicles of f<8 layers, 4 used pedicle screw fixation, and the other 4 used laminar screw fixation. A self-defined pedicle screw grading system was used to evaluate the excellence, and the result showed that,f>9 layers: 14 pedicles were class A, 2 were class B, none was class C;f=9 layers: 16 pedicles were class A, 7 were class B, 4 were class C; f=8 layers: 3 pedicles were class A, 5 were class B, 8 were class C; f<8 layers: none was pedicles class A or class B, 4 were class C. The other 4 lamina screws fixation didn’'t invade the spinal canal. One case of pedicle class C showed clinical manifestations of mild dizziness and drowsiness. The patients were followed up for 6-11 months with an average of (8±3) months, and the fracture or bone graft fusion were observed after 6 months of following-up.ConclusionBased on preoperative CTA thin layer scanning, through measuring and reading continuous layers of transverse process hole pedicle height more than or equal to 4 mm, can effectively judge the security of axial pedicle screws in order to subsequently choose the reasonable operation methods so as to improve success rate and decrease surgical risk.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
  • Study on the risk of injury to the middle sacral artery during the fixation of S1 vertebra with three cortical fixation techniques

    ObjectiveTo investigate the distance between the screw-out point and the middle sacral artery, and evaluate the safety when the S1 pedicle screw placed by the three cortical fixation techniques.MethodsFrom March to June 2018, randomized CT scan data of 98 adult pelvic angiography were selected to measure the distance from the middle sacral artery to the anterior edge of the vertebral body (a) and the distance from the middle sacral artery to the midline of the vertebral body (b). S1 screw entry point was set as the intersection of lines where extension of S1 facet joint inferior margin and lateral margin cross over. Introversion angles of 10, 15, 20, and 25° were used; the distance between the screw insertion point and the middle sacral artery (d) was measured.ResultsThe middle sacral artery was usually located on the left side of the upper endplate plane of S1. The distance a was (5.40±2.95) mm in 49 males and (4.43±2.32) mm in 49 females, and the difference between the males and females was not statistically significant (t=1.818, P=0.72). The distance b was (12.07±5.42) mm in 45 males and (14.12±4.88) mm in 48 females, and the difference between the males and females was not statistically significant (t=–1.914, P=0.59). The distance d was (12.67±6.00), (9.40±5.17), (7.50±3.76), and (8.10±3.64) mm when the nail was placed at a common internal inclination of 10, 15, 20, and 25°. The differences in the distance d at a common internal inclination of 10° vs. 15°, 10° vs. 20°, 10° vs. 25°, and 15° vs. 20° were all statistically significant (t=16.828, 11.609, 6.073, 6.254; P<0.008 3); there was no statistically significant difference in that at 15°vs. 25°, or 20° vs. 25° (t=2.034, –1.723; P>0.05).ConclusionBy analyzing the relationship between the middle sacral artery and the upper endplate plane of the S1 vertebra, the risk of middle artery injury is small while the biomechanical stability of the screw is increased when using the Lenham method.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
  • Surgical treatment strategy for the “shell” phenomenon after thoracolumbar fracture

    ObjectiveTo explore the surgical treatment strategy of the vertebral " shell” after thoracolumbar fracture, and provide clinical reference for the intervention and treatment of " shell”.MethodsBetween June 2015 and January 2017, 53 patients with high risk of vertebral " shell” after thoracolumbar fracture surgery were enrolled in a prospective study according to the selection criteria. All patients were randomly divided into two groups according to the order of treatment, 27 cases in the treatment group were treated with short-segment fixation combined with vertebral reconstruction, 26 cases in the control group were treated with short-segment fixation. There was no significant difference in gender, age, injury cause, Denis classification, fracture segment, the degree of injured vertebra compression, bone mineral density, and American Spinal Cord Injury Association (ASIA) classification between the two groups (P>0.05). The degree of injured vertebra compression, visual analogue scale (VAS) score, and Oswestry disability index (ODI) score at preoperation, immediate after operation, and last follow-up were calculated and compared between the two groups. The " shell” phenomenon and surgery complications were observed at the same time.ResultsAll patients were followed up 12-18 months with an average of 14.4 months. There were 5 cases of " shell” phenomenon in the treatment group and 4 cases of nonunion at last follow-up, 23 cases of " shell” phenomenon in the control group and 19 cases of nonunion at last follow-up; there was a significant difference between the two groups (P<0.05). In the treatment group, 1 case had incision fat liquefaction and 4 cases had bone cement leakage; in the control group, 2 cases had screw loosening and 1 case had unilateral connecting rod rupture; there was no significant difference in the incidence of complications between the two groups (χ2=0.504, P=0.478). The degree of injured vertebra compression, VAS score, and ODI score were significantly improved in both groups at immediate after operation and last follow-up (P<0.05). There was no significant difference in the degree of injured vertebra compression between the two groups at immediate after operation (P>0.05), but which was significantly higher in the control group than that in the treatment group at last follow-up (P<0.05). Except that the ODI score of the control group was significantly higher than that of the treatment group at last follow-up (P<0.05), there was no significant difference in VAS score and ODI score between the two groups at the other time points (P>0.05).ConclusionThe treatment of thoracolumbar fracture with short-segment fixation combined with injured vertebral reconstruction can effectively prevent the " shell” phenomenon, which is conducive to maintaining the height of injured vertebral and improving the long-term function. The effectiveness is satisfactory.

    Release date:2019-01-03 04:07 Export PDF Favorites Scan
  • Comparative study on the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures

    ObjectiveTo compare the effectiveness of improved and traditional Kirschner wire tension band fixation in treatment of type C patellar fractures.MethodsBetween January 2017 and January 2019, 26 patients with type C patellar fractures were treated with improved Kirschner wire tension band fixation (group A), and 24 patients were treated with traditional Kirschner wire tension band fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, and side and type of fracture between 2 groups (P>0.05). The operation time, intraoperative blood loss, the visual analogue scale (VAS) scores at 1 and 3 days after operation, the fracture healing time, and the occurrence of complications (skin irritation of Kirschner wires, failure of internal fixation, fracture reduction loss) were recorded, and the knee function was evaluated by Lysholm scoring standard in 2 groups.ResultsThe operation time in group A was significantly less than that in group B (t=−4.742, P=0.000). There was no significant difference in the intraoperative blood loss and VAS scores at 1 and 3 days after operation between 2 groups (P>0.05). All incisions healed by first intention. All patients were followed up 8-15 months, with an average of 11 months. The fracture healing time was (3.3±0.6) months in group A and (3.2±0.6) months in group B, showing no significant difference (t=0.589, P=0.559). At last follow-up, the knee joint function was evaluated according to Lysholm scoring standard. And there were 15 cases of excellent, 8 cases of good, and 3 cases of fair, with an excellent and good rate of 88.5% in group A; there were 8 cases of excellent, 7 cases of good, 7 cases of fair, and 2 cases of poor, with an excellent and good rate was 62.5%. The difference between 2 groups was significant (Z=2.828, P=0.005). The internal fixators were removed after the fracture healed in 2 groups. At last follow-up, no skin irritation of Kirschner wires occurred in group A, but 3 cases in group B. X-ray films reexamination showed that 5 cases of internal fixation failure and no fracture reduction loss were found in group A, while 9 cases of internal fixation failure and 1 case of fracture reduction loss in group B. The incidence of complications in group A was 19.2% (5/26), which was significantly lower than that in group B (54.2%, 13/24) (χ2=6.611, P=0.010).ConclusionCompared with the traditional Kirschner wire tension band fixation, the improved Kirschner wire tension band fixation in treatment of type C patellar fracture can shorten the operation time, reduce the incidence of complications, and benefit the functional recovery of knee joint.

    Release date: Export PDF Favorites Scan
  • Effect of percutaneous pedicle screw fixation on the reduction of thoraculumbar burst fractures with posterosuperior fracture fragment

    Objective To explore the effectiveness of percutaneous pedicle screw fixation on the indirect reduction of posterosuperior fracture fragment in the thoraculumbar burst fractures. Methods Patients with thoracolumbar fractures treated in the Fourth People’s Hospital of Zigong from September 2017 to September 2019 were collected retrospectively. All patients were treated with percutaneous pedicle screw fixation. The main observation indexes before operation, 3 days after operation and 1 year after operation were compared, including the height ratio of the anterior margin of fractured vertebra, the inversion angle of posterosuperior fracture fragment, the fragment displacement, the occupancy rate of spinal canal, the Cobb angle of kyphosisat, Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI). Results A total of 38 patients were included. All patients were followed up for more than 1 year. During the follow-up period, there were no complications such as nerve injury, incision infection, internal fixation loosening or fracture. The operation time was (91.7±10.4) min, the amount of intraoperative bleeding was (94.3±19.5) mL, and the length of surgical incision was (9.3±1.8) cm. The height ratio of the anterior margin of fractured vertebra, the inversion angle of posterosuperior fracture fragment, the fragment displacement, the occupancy rate of spinal canal, the Cobb angle of kyphosisat 3 days after operation were significantly improved compared with those before operation (P<0.05); the height ratio of the anterior margin of fractured vertebra, the occupancy rate of spinal canal, and the Cobb angle of kyphosisat 1 year after operation were also significantly improved compared with those before operation (P<0.05); the height ratio of the anterior margin of fractured vertebra and the occupancy rate of spinal canalat 1 year after operation were significantly improved than those 3 days after operation (P<0.05), but the Cobb angle of kyphosis 1 year after operation was significantly lost than that 3 days after operation (P<0.05). The VAS score and ODI index 3 days and 1 year after operation were significantly improved compared with those before operation (P<0.05), and the VAS score and ODI index 1 year after operation were improved compared with those 3 days after operation (P<0.05). Conclusion The percutaneous pedicle screw fixation can effectively reduce the retropulsed bone fragment indirectly and restore the Cobb angle of kyphosis of the thoraculumbar burst fractures without neurological deficit, and at the same time reduce the operation time and surgical trauma.

    Release date: Export PDF Favorites Scan
  • Clinical effect of occipito-cervical fusion and causes of postoperative dysphagia: a preliminary study

    Objective To explore the clinical effect of occipital-cervical fusion and its impact on cervical curvature, and preliminarily study the causes of postoperative dysphagia. Methods The data of 24 patients who underwent occipito-cervical fusion in the Fourth People’s Hospital of Zigong between January 2014 and December 2018 were retrospectively analyzed, including 13 males and 11 females, aged 33-82 years, with an average age of (58.3±13.3) years. Among them, there were 14 cases of atlas fractures, 6 cases of atlantoaxial fractures, 1 case of intraspinal canal space-occupying lesion, 2 cases of chronic atlantoaxial dislocation with spinal cord compression, and 1 case of instability caused by inflammatory diseases. Japanese Orthopedic Association (JOA) score and Visual Analogue Scale (VAS) score were used to evaluate neurological function and pain of patients preoperatively and postoperatively. Occipito-cervical angle (O-C2) and lower cervical angle (C2-C7) were measured to evaluate the preoperative and postoperative angle changes in patients. The causes of postoperative dysphagia were analyzed. Results All the 24 patients were followed up for 8-50 months (26.3 months on average). The mean JOA score increased from 11.6±1.5 before surgery to 15.4±1.2 at the last follow-up, and the mean VAS score decreased from 6.4±1.1 before surgery to 2.0±0.6 at the last follow-up; the differences between the two time points were statistically significant (P<0.001). The bone graft fusion rate was 95.8% (23/24). The mean O-C2 angle decreased from (16.5±7.6)° before surgery to (14.7±4.5)° at the last follow-up, with no statistical significance (P=0.395). The mean angle of C2-C7 increased from (9.4±5.5)° before surgery to (16.3±3.5)° at the last follow-up, and the difference was statistically significant (P<0.001). Two patients developed postoperative dysphagia, possibly due to fusion in a flexion position. Conclusion Occipito-cervical fusion has reliable efficacy in treating occipito-cervical instability, with a high fusion rate and a low incidence of complications, but it will change the physiological curvature of upper and lower cervical vertebra, and fusion in a flexion position may cause postoperative dysphagia.

    Release date:2019-09-06 03:51 Export PDF Favorites Scan
  • Clinical application of individualized S1 pedicle screw placement

    ObjectiveTo explore the feasibility of the clinical application of individualized simulated S1 pedicle screw.MethodsThe data of patients with lumbar disease diagnosed and treated in the Fourth People’s Hospital of Zigong from May 2017 to April 2019 were retrospectively analyzed. According to the preoperative individualized design of the S1 pedicle screw placement path, the patients were divided into individualized screw placement group and traditional screw placement group. The distance D between the screw tip and the endplate of the S1, the angle α of the screw in the plane of the dysplasia and the lumbar pedicle of the L5, the angle of oblique angle β, the number of screws of 35 and 40 mm in length, and the screw loosening rate (followed-up within 1 year) in the two groups were analyzed.ResultsA total of 59 patients were enrolled in this study, 31 in the individualized screw placement group and 28 in the traditional screw placement group. The differences in the distance D between the screw tip and the endplate of the S1 [(2.61±0.82) vs.(4.13±1.51) mm; t=-5.718, P<0.001], the angle α of the screw in the plane of the dysplasia and the lumbar pedicle of the L5 [(9.31±3.52) vs. (13.53±4.78)°; t=-5.646, P<0.001], the angle of oblique angle β [(15.73±6.04) vs. (10.65±5.09)°; t=3.022, P=0.004], the proportion of using screw models [40 mm in length: 56 vs. 8; 35 mm in length: 6 vs. 48; χ2=68.539, P<0.001], and the screw loosening rate followed-up within 1 year [3.22% vs. 16.07%; χ2=5.774, P<0.001] were statistically significant between the individualized screw placement group and the traditional screw placement group.ConclusionsPreoperative individualized design of the pedicle screw of the S1 pedicle screw can be used in clinical practice. The biomechanical stability of the S1 pedicle screw can be improved and the sagittal balance can be achieved.

    Release date:2019-09-06 03:51 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content