west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "ZHUDa" 5 results
  • Per-ventricular Device Closure of Doubly Committed Sub-arterial Ventricular Septal Defect ——Technical Consideration and Perioperative Management

    Doubly committed sub-arterial ventricular septal defect (VSD) is a unique type of VSD which is located beneath both the aortic and pulmonary valve. Open-heart repair is traumatic especially for pediatric patient while trans-catheter device closure is also not suitable for this type of VSD. Minimally invasive per-ventricular device closure has been introduced as an alternative method in the treatment of doubly committed VSD with encouraging results. In the review, we will illustrate the surgical technique as well as perioperative management strategy as for this technique in treating doubly committed VSD.

    Release date: Export PDF Favorites Scan
  • Surgical Treatment of Bicuspid Aortic Valve Combined with Toracic Aortic Dilation

    ObjectiveTo analyze the clinical characteristics and surgical treatment of bicuspid aortic valve combined with thoracic aortic dilation. MethodsWe retrospectively analyzed the clinical data of 68 patients of bicuspid aortic valve combined with thoracic aortic dilation underwent surgical treatment in our hospital between January 2010 and June 2014. There were 47 males and 21 females at age of 26-77(44.5±16.3) years. Different surgical treatments including Wheat procedure(n=22), aortic valve replacement+ascending aortoplasty(n=10), Bentall procedure(n=13), aortic valve replacement+ascending aortic replacement+right hemi aortic arch replacement(n=13), Bentall procedure+ascending aortic replacement+right hemi aortic arch replacement(n=8), Bentall procedure+ascending aortic replacement+total arch replacement+stented elephant trunk(n=2) were carried out according to the type. ResultsAll 68 patients underwent surgical treatment. The mortality in hospital is at 4.4%(3/68). The postoperative complications were neurological and mental complications(n=3), pneumonia(n=2), and exploratory thoracotomy(n=2). We followed up 63 patients for 6 months to 4 years. A total of 62 patients were well without reoperation except one death at the end of following-up 2 years. ConclusionBicuspid aortic valve combined with thoracic aortic dilation has diversiform clinical characteristics. The surgical treatment should be chosen according to the aortic valve and thoracic aortic lesion characteristics.

    Release date: Export PDF Favorites Scan
  • Hybrid Perventricular Closure for Pediatric Patients with Muscular Ventricular Septal Defect: Experience from West China Hospital

    ObjectiveTo investigate the efficacy and safety of hybrid perventricular device closure (PVDC) for the treatment of muscular ventricular septal defect (MVSD) in pediatric patients. MethodsWe retrospectively analyzed clinical data of 35 pediatric patients with MVSD who received hybrid PVDC in West China Hospital between 2009 and 2012. There were 16 males and 19 females with their median age of 3.9 years (range, 1 month to 7 years). There were 10 patients with single MVSD, 12 patients with multiple MVSD, 6 patients with other congenital heart defects, and 7 patients with post-surgical residual MVSD. ResultsAmong the 35 patients, immediate complete closure was achieved in 28 (80.0%) patients. Residual shunt was noted in 7 (20.0%) patients. Median device size was 5 mm. Cardiopulmonary bypass was avoided in 19 patients. Two (5.7%) patients died postoperatively due to postoperative heart failure resulted from complex congenital heart defect. All survival patients were followed up for a mean duration of 6 months, and there was no late death. Thirty-one (93.9%) patients had good positioning of the closure devices but no residual shunt. Small residual shunt at the apex was noted in 2 (6.1%) patients. ConclusionHybrid PVDC is an effective treatment for MVSD with relatively high successful rate but low mortality and morbidity, and its short-term results are satisfactory.

    Release date:2016-10-02 04:56 Export PDF Favorites Scan
  • Application of Three-dimensional CT Angiogram in Perioperative Evaluation for Patients Underwent Transapical Aortic Valve Implantation——The Initial Experience from West China hospital

    ObjectiveTo introduce the role of three dementional computed tomograph (3D-CT) for patients underwent transcatheter aortic valve implantation (TAVI) procedure in perioperative evaluation. MethodsFrom April 2014 to June 2015, we retrospectively analyzed clinical data of 28 patients with severe aortic stenosis underwent successful TAVI procedure using new second-generation device, who were enrolled in this study including 12 males and 16 females at mean age of 72.8±4.5 years. We used 3D-CT to get the perioperative relative evaluation, including valve morphology and calcification degree, annular diameter, aoronary ostium height, ascending aorta, aortic sinus diameter, left ventricular-aortic angle, optimal intraoperative angiogram projection angle. Based on the evaluation by 3D-CT image, the prosthesis size, balloon size, best intraoperative imaging projection angle and approach of apex were then chosen. ResultsAll patients with severe aortic stenosis underwent successful TAVI procedure with mean logistic Euro-SCORE I:26.2%±7.9%. CT image revealed that mean aortic annular diameter was 24.6±1.8 mm with mean valve prosthesis size 25.8±1.1 mm and pre-dilation balloon size 23.1±1.2 mm and 76.8% patients were of tricuspid aortic valve with severe calcification and 25% patients were of asymmetric calcification. Optimal intraoperative angiogram image was achieved in 92.9% patients with the help of preoperative CT image. There was a statistic difference in mean transvalvular gradient after valve implantation (54.1±15.3 mm Hg vs. 13.1±8.5 mm Hg, P<0.05). And there was no mortality or severe complication postoperatively. Conclusion3D-CT image palys an important role during perioperative evaluation of TAVI procedure and it can be helpful for Chinese doctors to operate TAVI successfully.

    Release date: Export PDF Favorites Scan
  • Safety and Efficacy of Perventricular Device Closure of Subarterial Ventricular Septal Defect

    ObjectiveTo assess the safety and efficacy of a new surgical strategy, perventricular device closure, for the treatment of subarterial ventricular septal defect (VSD). MethodsThirty-nine patients younger than 10 years with subarterial VSD who received surgical repair in West China Hospital from November 2010 to May 2012 were included in this study. There were 18 male and 21 female patients with their age of 5.9±3.2 years. Perventricular device closure was performed with eccentric device under the guidance of transesophageal echocardiography (TEE). Residual shunt, valvular regurgitation (including aortic regurgitation)and arrhythmias during perioperative period and follow-up were analyzed. ResultsThirty-three patients successfully received perventricular device closure, and 6 patients received conversion to open surgical repair. Postoperative ICU stay was 2.2±0.8 days, and length of hospital stay was 4.8±1.8 days. Major postoperative complications included residual shunt and mild or less aortic regurgitation. Mean follow-up duration was 7±2 months. No obvious arrhythmia, moderate or severe valvular regurgitation was observed during follow-up. ConclusionPerventricular device closure is safe, efficacious and minimally invasive for the treatment of subarterial VSD in pediatric patients with suitable anatomic characteristics with good mid-term results.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content