Objective To compare effects, advantages and disadvantages of simple internal fixation to that of l imited internal fixation with external supporting frame fixation in the treatment of complex fractures of tibial plateau. Methods From July 2002 to August 2006, 66 cases of complex fractures of the tibial plateau were divided into the internal fixation group (n=39) and the external fixator group (n=27). The interal fixation group had 18 cases of IV, 7 cases V and 14 cases VI according to Schatzker, including 25 males and 14 females aged 18-79 years with an average of 45.4 years. The external fixator group had 13 cases of IV, 6 cases V and 8 cases VI according to Schatzker, including 18 males and 9 femles aged 18-64 years with an average of 44.2 years. No significant difference was evident between the two groups (P gt; 0.05). Patients were treated by using screws, steel plates or external supporting frame fixation strictly based on the princi ple of internalfixation. Results All patients were followed up for 1-5 years. Fracture healed with no occurrence of nonunion. Two cases inthe internal fixation group presented partial skin infection and necrosis, and were cured through the dressing change and flap displacement. Fracture heal ing time was 6-14 months with an average of 7.3 months. The time of internal fixator removal was 6-15 months with an average of 8.3 months. In the external fixation group, 11 cases had nail treated fluid 7 days to 3 months after operation, combining with red local skin; 3 cases had skin necrosis; and 3 cases had loose bolts during follow-up. Through debridement, dressing change and flap displacement, the skin wounds healed. Fracture heal ing time was 3-11 months with an average of 5.1 months. The time of external fixator removal was 5-11 months with an average of 6.4 months. At 8-14 months after operation, the knee function was assessed according to Merchant criteria. In the internal fixation group, 29 cases were excellent, 4 good, 5 fair and 1 poor, while in the external fixation group, 20 cases were excellent, 3 good, 2 fair and 2 poor. There was no significant difference between the two groups (P gt; 0.05). Conclusion The therapeutic effects of simple internal fixation and l imited internal fixation with external supporting frame fixation were similar in the treatment of complex fractures of tibial plateau. Fixation materials should be selected according to the state of injury and bone conditions for the treatment of tibial plateau fracture of type IV, V and VI based on Sehatzker classification.
ObjectiveTo evaluate the effectiveness of comprehensive management for early stage avascular necrosis of the femoral head (ANFH) by arthroscopic minimally invasive surgery by comparing with closed core decompression. MethodsBetween January 2007 and March 2010, 28 patients (33 hips) with early stage ANFH were treated with the procedure of arthroscopic core decompression combined with autogenous cancellous bone graft and bone morphogenetic protein (BMP) in 18 cases (21 hips, trial group) or with simple closed core decompression in 10 cases (12 hips, control group). No significant difference was found in gender, age, disease duration, etiology, and staging between 2 groups (P gt; 0.05). ResultsIncision healed primarily in all patients, and no infection occurred. All patients were followed up 2.5 years on average (range, 1-3 years). Pain relief and improvement of hip function were obtained in all patients at 6 months after operation. At last follow-up, the Harris scores were 85.67 ± 4.78 in trial group and 81.33 ± 7.03 in control group, showing significant difference between 2 groups (t= —2.10, P=0.04). Collapse of the femoral head was observed in 1 hip (Ficat stage II) of trial group, and in 2 hips (Ficat stage I ) and 2 hips (Ficat stage II) of control group; hip arthroplasty was performed. Significant difference in total effective rate was found between trial group and control group (95.24% vs. 66.67%; χ2=4.85, P=0.03). ConclusionArthroscopic core decompression combined with autogenous cancellous bone graft and BMP is more effective than traditional closed core decompression for treatment of early stage ANFH in pain relief, improvement of hip function, slowing-down the process of femoral head necrosis, reduction of hip joint replacement by accurate location of the lesions, and thoroughly debridement of necrotic bone.
目的 了解依托芬那酯凝胶对有疼痛症状的轻中度拇外翻畸形的治疗效果。 方法 对2010年3月-2011年7月门诊收治的轻中度拇外翻患者共65足,随机分成两组,治疗组采取托芬那酯凝胶局部应用和佩戴夜间支具,对照组佩戴夜间支具,局部应用安慰剂,治疗周期1个月。记录症状明显缓解时间,治疗前后对患者进行视觉模拟疼痛评分和美国骨科足踝分会跖趾及趾间关节评分,并测量拇外翻角和第一跖骨间角改变。 结果 全部患者完成治疗,疼痛缓解时间治疗组为(3.28 ± 1.04)d,对照组(7.03 ± 2.15)d,差异有统计学意义(P<0.05),佩戴足矫形器治疗1个月,拇外翻角和第一跖骨间角改变无统计学差异(P>0.05)。 结论 局部应用依托芬那酯凝胶结合足矫形器治疗轻中度拇外翻能快速缓解疼痛症状,改善活动能力,延缓畸形加重,依托芬那酯凝胶局部给药患者能良好耐受,可避免口服非甾体抗炎药(NSAIDs)带来的副作用。
ObjectiveTo explore the clinical effect of open reduction and internal fixation with hollow screw fixation in the treatment of difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus.MethodsFrom January 2011 to March 2014, 15 patients with difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus were treated with open reduction and hollow screw fixation. There were 9 males and 6 females, aged from 45 to 77 years with an average of 63.5 years. The causes of injury included 7 cases of falls, 5 cases of high falling injury, and 3 cases of traffic accident injury. The injury-to-admission time was 2 hours to 5 days with an average of 1.5 days. The shoulder joint was the initial dislocation. The types of dislocation showed 14 cases of anterior dislocation and 1 case of posterior dislocation. There were 9 cases of simple avulsion fracture of greater tuberosity of humerus, 5 cases of comminuted fracture, 1 case of both greater tuberosity of humeru with small tuberosity of humerus fracture, and 2 cases of incomplete nerve injury; no exploration was carried out in operation.ResultsThere were 14 patients with wound healing at first intention; 1 suffered superficial infection of the wound, which healed by anti infection treatment. Fifteen cases were followed up for 6 to 18 months with an average of 12.2 months, with 1 case of shoulder joint re-dislocation 1 month after operation, and 2 cases of tuberosity of humerus defect absorption. One year after operation, the shoulder joint function were evaluated according to Neer Scoring System, and the results were excellent in 9 cases, good in 3 cases, fair in 2 cases, and poor in 1 case, with the excellent and good rate of 80.0%.ConclusionThe curative effect of open reduction and internal fixation with hollow screw fixation on difficult reduction of shoulder joint dislocation combined with fracture of greater tuberosity of humerus is remarkable, which can obtain satisfactory shoulder joint function.
ObjectiveTo investigate the effectiveness of two surgical approaches in the treatment of type Ⅳ Pipkin fracture.MethodsThe clinical data of 15 patients with type Ⅳ Pipkin fracture treated surgically between July 2013 and June 2018 were retrospectively analyzed. According to different surgical approaches, they were divided into group A (8 cases, using K-L posterior approach) and group B (7 cases, using greater trochanter osteotomy approach). There was no significant difference in gender, age, cause of injury, and interval from injury to operation between the two groups (P>0.05). The incision length, operation time, intraoperative blood loss, hospital stay, fracture healing time, and complications of the two groups were recorded. Hip joint function recovery was evaluated according to Thompson-Epstein functional evaluation system.ResultsAll the 15 patients were followed up 1-5 years, with an average of 2.5 years. There was no significant difference in operation time between the two groups (t=14.681, P=0.100); the incision length, intraoperative blood loss, and fracture healing time in group A were all greater than those in group B, and the hospital stay was shorter than that in group B, showing significant differences (P<0.05). In group A, 1 patient presented hip pain, clasthenia, and limited mobility after operation, 1 patient presented ossifying myositis, 1 patient presented osteonecrosis of the femoral head, 1 patient presented fat liquefaction of incision, and 1 patient presented sciatica, with a complication incidence of 62.5%. Postoperative hip pain occurred in 1 patient and ossifying myositis in 2 patients in group B, with a complication incidence of 42.9%. There was no significant difference in the incidence of complications between the two groups (χ2=−0.735, P=0.462). At last follow-up, according to Thompson-Epstein functional evaluation system, the results in group A were excellent in 3 cases, good in 2 cases, fair in 2 cases, and poor in 1 case, with an excellent and good rate of 62.5%; in group B, the results were excellent in 4 cases, good in 2 cases, and fair in 1 case, and the excellent and good rate was 85.7%. There was no significant difference in good and fair rate between the two groups (χ2=−0.990, P=0.322).ConclusionK-L posterior approach is more convenient in the fracture treatment during operation, but it has greater trauma, greater vascular damage, and more blood loss. The greater trochanter osteotomy approach can better protect the blood supply of femoral head, shorten the operation time, reduce intraoperative blood loss, and reduce postoperative complications. It is an ideal way in the surgical treatment of type Ⅳ Pipkin fracture.
ObjectiveTo manufacture a polycaprolactone (PCL)/type Ⅰ collagen (COL Ⅰ) tissue engineered meniscus scaffold (hereinafter referred to as PCL/COL Ⅰ meniscus scaffold) by three-dimensional (3D) printing with low temperature deposition technique and to study its physicochemical properties.MethodsFirst, the 15% PCL/4% COLⅠ composite solution and 15% PCL simple solution were prepared. Then, 15% PCL/4% COL Ⅰmeniscus scaffold and 15% PCL meniscal scaffold were prepared by using 3D printing with low temperature deposition techniques. The morphology and microstructure of the scaffolds were observed by gross observation and scanning electron microscope. The compression modulus and tensile modulus of the scaffolds were measured by biomechanical test. The components of the scaffolds were analyzed by Fourier transform infrared spectroscopy (FTIR). The contact angle of the scaffold surface was measured. The meniscus cells of rabbits were cultured with the two scaffold extracts and scaffolds, respectively. After cultured, the cell proliferations were detected by cell counting kit 8 (CCK-8), and the normal cultured cells were used as controls. Cell adhesion and growth of scaffold-cell complex were observed by scanning electron microscope.ResultsAccording to the gross and scanning electron microscope observations, two scaffolds had orientated 3D microstructures and pores, but the surface of the PCL/COLⅠ meniscus scaffold was rougher than the PCL meniscus scaffold. Biomechanical analysis showed that the tensile modulus and compression modulus of the PCL/COL Ⅰ meniscus scaffold were not significantly different from those of the PCL meniscus scaffold (P>0.05). FTIR analysis results showed that COL Ⅰ and PCL were successful mixed in PCL/ COL Ⅰ meniscus scaffolds. The contact angle of PCL/COLⅠ meniscus scaffold [(83.19±7.49)°] was significantly lower than that of PCL meniscus scaffold [(111.13±5.70)°] (t=6.638, P=0.000). The results of the CCK-8 assay indicated that with time, the number of cells cultured in two scaffold extracts showed an increasing trend, and there was no significant difference when compared with the control group (P>0.05). Scanning electron microscope observation showed that the cells attached on the PCL/ COL Ⅰ meniscus scaffold more than that on the PCL scaffold.ConclusionPCL/COLⅠmeniscus scaffolds are prepared by 3D printing with low temperature deposition technique, which has excellent physicochemical properties without cytotoxicity. PCL/COLⅠmeniscus scaffold is expected to be used as the material for meniscus tissue engineering.