This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.
Objective To evaluate the clinical effectiveness of valve-sparing aortic root replacement (VSARR) in the treatment of patients with dilated aortic root after operation for tetralogy of Fallot (TOF). Methods A retrospective analysis was conducted on clinical data of TOF patients with aortic root dilation who underwent VSARR in our hospital from 2016 to 2022. Results Finally 14 patients were collected, including 8 males and 6 females, with a median age of 22 years ranging from 12-48 years. Among them, 5 patients had severe aortic valve regurgitation, 4 moderate regurgitation, and 5 mild or no regurgitation. Six patients had sinus of valsalva dilation, and 8 significant dilation of the ascending aorta. One patient had residual shunt due to ventricular septal defect, and 9 severe pulmonary valve regurgitation. The David procedure was performed in 10 patients, Yacoub procedure in 2 patients, and Florida sleeve in 2 patients. There was no perioperative mortality in the group. The median follow-up time was 2.9 years (ranging from 0.4 to 6.0 years). One patient had mild aortic valve regurgitation, and the rest had minimal or no regurgitation. One patient had mild stenosis of the left ventricular outflow tract, and the rest patients had no obvious stenosis. Conclusion VSARR is a satisfactory treatment for aortic root dilation in patients with TOF, with no significant increase in the incidence of left ventricular outflow tract stenosis or aortic regurgitation during mid-term follow-up.