Abstract: Objective To summarize surgical results of secondary subaortic stenosis (SSS) after congenital heart disease (CHD) operations,and analyze the pathogenesis of SSS. Methods We retrospectively analyzed clinical data of 19 patients who underwent surgical repair for SSS in Guangdong General Hospital from 1st June 2008 to 31st December 2012. There were 10 males and 9 females. CHD types included double outlet right ventricle,ventricular septal defect and partial atrioventricular septal defect,et al. The median age of the patients when they received their first CHD operations was 4 months (15 days to 5 year and 11 months). The median age of the patients when they received SSS repair was 5 years and 3 months (1 year to 15 years and 3 months). The median time interval from CHD operation to SSS repair was 4 years and 10 months (8 months to 13 years and 11 months). Results All the patients successfully received their SSS repair. There was no surgical death in this study. Median cardiopulmonary bypass time was 79 (39 to 172) minutes,and median aortic cross-clamp time was 42 (22 to 124) minutes. Median postoperative hospital stay was 7 (5 to 9) days. Postoperatively, 1 patient required permanent pacemaker implantation. All the patients were followed up after discharge for a median durationof 1 year and 10 months (5 months to 4 years and 4 months) . During follow-up, none of the patients had any clinical symptom,their heart function was normal,and there was no late death. One patient received another subaortic stenosis repair for gradually aggravating left ventricular outflow tract stenosis. Conclusions SSS is very rare after CHD operations. The pathogenesis of SSS is perhaps related to abnormal blood flows in the left ventricular outflow tract after CHD operations. The pathogenesis time of SSS and types of CHD leading to SSS cannot be predicted. Subaortic stenosis repair is a simple and safe procedure for SSS,but postoperatively left ventricular outflow tract stenosis may appear and aggravate again.
The purpose of this study was to explore the feasibility of dual-source computed tomography (DSCT) high-pitch scan mode in the preoperative evaluation of severe aortic stenosis (AS) referred to transcatheter aortic valve implantation (TAVI). Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography. Measurement and calculation of contrast, contrast noise ratio (CNR) and noise of aorta and access vessels were performed. The intra-and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated. Evaluation of shape and plagues of aorta and access vessels was performed. The contrast, CNR and noise of aorta and access vessels were 348.2~457.9 HU, 12.2~30.3 HU and 19.1~48.1 HU, respectively. There were good intra-and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT (mean difference:-0.73~0.79 mm, r=0.90~0.98, P < 0.001; mean difference:-0.70~0.73 mm, r=0.90~0.96, P < 0.001). In the 30 patients, the diameters of external iliac artery, femeral artery or subclavian artery were less than 7 mm in 5 cases (16.7%), marked calcification in bilateral common iliac arteries in 1 case (3.3%) and marked soft plaque in left common iliac artery in 1 case (3.3%). DSCT high-pitch scan mode was feasible in the preoperative evaluation of aorta and access vessels in patients with AS referred for TAVI.
Objective To search and review the best clinical evidence to compare the clinical therapeutic effects and safety between TAVR and SAVR, thereby guiding its clinical use and providing references of treatments for such patients. Methods EMbase (1974~2016), MEDLINE (1996~2016) and The Cochrane Library (Issue 5, 2016) were systematically retrieved to collect randomized control trials, case-control studies and meta-analyses. Then, we assessed the quality of all the evidences to develop treatments based on those evidences and the situations of such patients. Results We identified 21 articles, including 2 articles of meta-analysis. With regard to the mortality and incidence of cardiovascular events, TAVR was not worse than SAVR. In addition, TAVR was more dominant than SAVR for patients who combined more basic diseases. Conclusion TAVR is one of the effective treatments for most patients with severe AS after sufficient assessment.
Objective To compare the efficacy and safety of transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with bicuspid aortic valve (BAV) versus tricuspid aortic valve (TAV). Methods This retrospective study included 252 consecutive patients with severe and symptomatic aortic valve stenosis undergoing TAVR in West China Hospital form April 2012 to September 2017, in whom 4 patients were excluded because of valve failure after surgical aortic valve replacement. Results Of the 248 patients, 131 had BAV and 117 had TAV. Baseline characteristics were similar between the two groups, including age [(73.56±6.35) vs. (74.31±6.35) years, P=0.354], male proportion (51.9% vs. 63.2%, P=0.072). Society of Thoracic Surgeons score for BAV patients was lower than that for TAV patients [(7.56±4.01)% vs. (8.78±5.14)%, P=0.037]. Procedural success rate was high in both BAV and TAV groups (95.4% vs. 98.3%, P=0.359). There was no difference in 30-day all-cause mortality (6.1% vs. 2.6%, P=0.176) between the two groups; the aortic valve maximum velocity of valve hemodynamics after TAVR was similiar [(2.39±0.53) vs. (2.31±0.45) m/s, P=0.262] between the two groups. Conclusions Patients with BAV show similar procedural and clinical outcomes to patients with TAV. Therefore, TAVR appears to be a safe and effective procedure for patients with BAV as well as those with TAV.
Objective To analyze the midterm outcome of patients with congenital aortic stenosis undergoing percutaneous balloon aortic valvuloplasty (PBAV) by single echocardiographic guidance. Methods The clinical data of 12 patients with congenital aortic stenosis who underwent PBAV by single echocardiographic guidance at Fuwai Hospital from January 2016 to November 2017 were retrospectively analyzed. There were 7 males and 5 females with an average age of 18.27±15.30 years. The preoperative peak pressure gradient was 61.8–110.0 (80.30±24.50) mm Hg, and 50% of patients had aortic regurgitation. Results All patients successfully underwent PBAV. Aortic annulus diameter was 18.65±3.17 mm and balloon diameter was 17.62±3.77 mm, with balloon diameter to annulus diameter ratio of 0.92±0.07. The peak transaortic gradient was 16-51 (36.72±12.33) mm Hg immediately after procedure, which was significantly different from the preoperation (P=0.000). During the follow-up period, the peak transaortic gradient was 21-58 (37.06±13.52) mm Hg, and there was no significant difference between the follow-up and immediate postoperation (P=0.310). Immediately after procedure and during follow-up, 58% of patients had aortic regurgitation, which was not statistically different from the preoperation (P=0.682). Conclusion Systematic use of Doppler echocardiographic guidance for PBAV is feasible, and that it is associated with a high success rate and a very low complication rate.
ObjectiveTo compare the efficacy and safety of Venus A-Valve and other overseas devices in transcatheter aortic valve replacement (TAVR) for patients with severe aortic stenosis (AS).MethodsWe retrospectively analyzed the baseline characteristics, procedural details, and postprocedural outcomes of severe AS patients who underwent TAVR with Venus A-Valve or overseas devices between April 2012 and January 2019 in West China Hospital of Sichuan University.ResultsA total of 342 AS patients undergoing TAVR were finally included, 238 with Venus A-Valve and the other 104 with overseas devices (43 with CoreValve, 33 with Lotus, 21 with SAPIEN XT, and 7 with SAPIEN 3). Baseline characteristics were comparable between the two groups, and the proportion of patients with bicuspid aortic valve was around 50% in both groups. After successful valve implantation, all patients’ hemodynamics were significantly improved, with the median of maximum velocity decreased to 2.30 m/s (inter-quartile range: 0.60 m/s) and 2.50 m/s (inter-quartile range: 0.62 m/s), respectively (P=0.003). Postprocedural 30-day and 1-year all cause mortalities were similar (30-day: 5.9% vs. 1.9%, P=0.086; 1-year: 8.4% vs. 5.8%, P=0.307), while low incidence of procedure-related complications and improved life quality were achieved in both groups.ConclusionTAVR with the domestic Venus A-Valve is feasible, safe, and can produce favorable outcomes for AS patients, and especially for Chinese TAVR population with a high prevalence of bicuspid aortic valve.
Objective To evaluate the clinical and follow-up results of the surgical treatment for hypertrophic obstructive cardiomyopathy associated with aortic stenosis. Methods We retrospectively analyzed the clinical data of the patients with hypertrophic obstructive cardiomyopathy plus aortic stenosis in our hospital from February 2008 to October 2015. There were 4 males and 3 females aged 55.6 ± 7.5 years. All the patients were received concomitant aortic valvulopasty at the time of modified extended Morrow procedure. Echocardiographic data and major complications were recorded through the outpatient clinic and telephone. Results The postoperative ventricular septal thickness, left ventricular outflow tract gradient and aortic gradient were significantly lower than those in preoperation with statistical differences (P<0.05). During the mean follow-up 25.6 ± 28.2 months period, 1 patient died of cerebral hemorrhage, 1 patient was implanted a permanent pacemaker, and 1 patient had a postoperative new-onset atrial fibrillation. All patients had a satisfied prosthetic valve function and the left ventricular outflow tract gradient. The patient's symptoms and heart function significantly improved postoperatively. Conclusion For patients with hypertrophic obstructive cardiomyopathy associated with moderate to severe aortic stenosis, concomitant aortic valvulopasty at the time of modified extended Morrow procedure is an appropriate and effective treatment, which can significantly alleviate the clinical symptoms, and improve quality of life with a satisfied prognosis.
ObjectiveTo summarize and analyze the risk factors and management of artificial valve slippage in transcatheter aortic valve implantation (TAVI).MethodsWe retrospectively analyzed the clinical data of 131 patients undergoing TAVI surgery in our center from September 2017 to May 2019, including 62 patients through transapical approach and 69 patients through transfemoral artery approach.ResultsA total of 131 patients received TAVI surgery, among whom 4 patients had slipped during the operation, 2 patients via transfemoral artery approach, and another 2 patients via transapical. The average age was 77±9 years with one female (25%). Preoperative evaluation, higher position and poor coaxial were main risk factors for valve slip in TAVI.ConclusionValve slippage is also a serious complication in TAVI surgery. Reasonable and effective treatment can avoid thoracotomy.
This article described the clinical diagnosis and treatment of a patient with bicuspid aortic stenosis occurring severe mitral regurgitation during transcatheter aortic valve replacement. Before transcatheter aortic valve replacement, the patient’s information about medical history, signs, evaluation of CT and echocardiography were collected. After discussion by the heart team, the trans-femoral aortic valve replacement was performed. After the valve was placed during the procedure, a severe mitral regurgitation occurred. No clear causes were found, and the patient’s hemodynamics was stable. The patient recovered well during follow-up, so surgery and other treatments were not considered. This article discussed the possible mechanism and solutions of mitral regurgitation during transcatheter aortic valve replacement, and owned certain value for similar cases to refer to.
An 82-year-old male was hospitalized complaining of dyspnea for 1 year and aggravating for 2 weeks. He had been treated in other hospitals for several times due to such situation and his symptom could be relieved by diuretics. After admission, he was diagnosed as severe aortic stenosis with extremely low left ventricular contractile function; transthoracic echocardiography showed a left ventricular ejection fraction of only 16.1%. He was classified as a typical case of severe aortic stenosis with “low transaortic velocity and low transaortic gradient” since the transaortic velocity being 2.36 m/s and transaortic gradient being 22/14 mm Hg (1 mm Hg=0.133 kPa). Dobutamine-stress echocardiography suggested that the patient’s left ventricular reserve function was extremely poor and the potential benefits of valvular surgery were finite as the former data being 2.59 m/s and 27/16 mm Hg respectively. In consideration of progressive exacerbation of the patient’s symptoms, we eventually conducted transcatheter aortic valve replacement surgery with the support of extracorporeal membrane oxygenation. His symptoms such as dyspnea disappeared after the surgery and clinical parameters had also got a significant improvement.