west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "artificial prosthesis" 2 results
  • Research progress on perception and feedback technology in artificial prosthesis

    Artificial prosthesis is an important tool to help amputees to gain or partially obtain abled human limb functions. Compared with traditional prosthesis which is only for decoration or merely has feedforward control channel, the perception and feedback function of prosthesis is an important guarantee for its normal use and self-safety. And this includes the information of position, force, texture, roughness, temperature and so on. This paper mainly summarizes the development and current status of artificial prostheses in the field of perception and feedback technology in recent years, which is derived from two aspects: the recognition way of perception signals and the feedback way of perception signals. Among the part of recognition way of perception signals, the current commonly adopted sensors related to perception information acquisition and their application status in prosthesis are overviewed. Additionally, from the aspects of force feedback stimulation, invasive/non-invasive electrical stimulation, and vibration stimulation, the feedback methods of perception signals are summarized and analyzed. Finally, some problems existing in the perception and feedback technology of artificial prosthesis are proposed, and their development trends are also prospected.

    Release date:2020-02-18 09:21 Export PDF Favorites Scan
  • Establishment of artificial joint aseptic loosening mouse model by cobalt-chromium particles stimulation

    ObjectiveTo explore the feasibility of establishment of a artificial joint aseptic loosening mouse model by cobalt-chromium particles stimulation.MethodsTwenty-four 8-week-old male severe combined immunodeficient (SCID) mice were divided into experimental group (n=12) and control group (n=12). The titanium nail was inserted into the tibial medullary cavity of mouse in the two groups to simulate artificial joint prosthesis replacement. And the cobalt-chromium particles were injected into the tibial medullary cavity of mouse in experimental group. The survival of the mouse was observed after operation; the position of the titanium nail and the bone mineral density of proximal femur were observed by X-ray film, CT, and Micro-CT bone scanning; and the degree of dissolution of the bone tissue around the tibia was detected by biomechanical test and histological staining.ResultsTwo mice in experimental group died, and the rest of the mice survived until the experiment was completed. Postoperative imaging examination showed that there was no obvious displacement of titanium nails in control group, and there were new callus around the titanium nails. In experimental group, there was obvious osteolysis around the titanium nails. The bone mineral density of the proximal tibia was 91.25%±0.67%, and the maximum shear force at the tibial nail-bone interface was (5.93±0.85) N in experimental group, which were significantly lower than those in control group [102.07%±1.87% and (16.76±3.09) N] (t=5.462, P=0.041; t=3.760, P=0.046). Histological observation showed that a large number of inflammatory cells could be seen around the titanium nails in experimental group, while there was no inflammatory cells, and obvious bone tissue formation was observed in control group.ConclusionThe artificial joint aseptic loosening mouse model can be successfully established by cobalt-chromium particles stimulation.

    Release date:2020-06-15 02:43 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content