west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "avulsion fracture" 27 results
  • BIOMECHANICAL STUDY ON SUTURE WITH NECKWEAR-KNOT-LOOPLIGATURE FOR TIBIAL EMINENCE AVULSION FRACTURES

    ObjectiveTo study the biomechanical stability of neckwear-knot-loop-ligature fixation for tibial eminence avulsion fractures by comparing with cannulated screw fixation and suture anchor fixation. MethodsTwenty-four fresh porcine knee joints were selected. After the model of tibial eminence avulsion fracture (type Ⅲ) was made, 24 samples were randomly divided into 3 groups: neckwear-knot-loop-ligature group (group A), cannulated screw group (group B), and suture anchor group (group C), 8 samples in each group. The Universal electromagnetic and mechanical testing machines were used for the biomechanical tests. After 200 cyclic tests, pull-out test was done until fixation failure. The maximum failure load, yield load, stiffness, and displacement were measured. ResultsFailure mode: the displacement was beyond limit in 8 samples of group A; screws extraction (5 samples) and bone fragment re-fracture (3 samples) were observed in group B; and suture anchor extraction (4 samples), suture rupture (3 samples), and suture thread cutting (1 sample) were found in group C. Biomechanical test: From groups A to C, the maximum failure load and yield load showed significant decreasing tendency (P<0.05), but the displacements showed significant increasing tendency (P<0.05). The stiffness also gradually decreased, but differences was not significant (P>0.05). ConclusionCompared with cannulated screw and suture anchor, neckwear-knot-loop-ligature fixation for tibial eminence avulsion fracture has good biomechanical performance and the advantages of firm fixation and simple operation.

    Release date: Export PDF Favorites Scan
  • Early effectiveness of minimally invasive open reduction and internal fixation versus arthroscopic double-tunnel suture fixation for tibial avulsion fracture of posterior cruciate ligament

    ObjectiveTo compare the early effectiveness of minimally invasive open reduction and internal fixation via posterior median approach versus arthroscopic double-tunnel suture fixation in treatment of tibial avulsion fracture of the posterior cruciate ligament (PCL).MethodsA clinical data of 31 patients with the tibial avulsion fracture of the PCL and met the criteria between January 2015 and January 2019 was retrospectively analyzed. Nineteen patients (group A) were treated with open reduction and internal fixation with cannulated screw via posterior median approach. The other 12 patients (group B) were treated with arthroscopic double-tunnel suture fixation technique. There was no significant difference between the two groups (P>0.05) in the gender, age, side of effected limb, the injury cause, the time from injury to operation, the combined meniscus injury, Meyers & McKeever classification and preoperative Lysholm score, Tegner score, International Knee Documentation Committee (IKDC) score, and the difference of tibial posterior displacement between bilateral knees. The operation time, postoperative complications, fracture healing, and the difference of tibial posterior displacement between bilateral knees, Lysholm score, Tegner score, and IKDC score were recorded.ResultsGroup B spent significantly longer operation time than group A (t=7.347, P=0.000). No postoperative complication occurred in group B, and 1 patient in group A had a screw breakage. All patients were followed up 6-36 months (mean, 22 months). X-ray films showed that all fractures healed at 3 months after operation. At last follow-up, there was no significant difference in the patients with normal knee range of motion between the two groups (P=0.510). At last follow-up, the difference of tibial posterior displacement between bilateral knees, Lysholm score, Tegner score, and IKDC score in the two groups were superior to those before operation (P<0.05); while there was no significant difference between the two groups (P>0.05).ConclusionFor the tibial avulsion fracture of PCL, the minimally invasive open reduction and internal fixation and arthroscopic double-tunnel suture fixation can obtain similar early effectiveness. However, arthroscopic surgery has the advantages of being able to simultaneously deal with intra-articular combined injuries, avoiding internal fixator complications, and eliminating the need for secondary operation.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Study on development and biomechanics test of plastic rod-hook plate

    ObjectiveTo develop a new type of internal fixation device which can be used to treat the minor avulsion fracture of the medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process, and investigate the reliability and effectiveness of the device through biomechanical test.MethodsEighty human’s bone specimens with complete medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process were selected and measured the anatomic indexes (the height, width, and thickness of medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process). The CT three-dimensional reconstruction data of 200 healthy adults which including medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process was also selected and measured the anatomic indexes by Mimics software. The plastic rod-hook plate was designed according to the measured results and prepared. Forty fresh porcine lower limb specimens were randomly divided into groups A and B (20 in each group), and 8 adult lower limb specimens including 4 left and 4 right were also randomly divided into groups A and B (4 in each group). All specimens were prepared for avulsion fracture of medial malleolus. Then, the fractures were fixed with plastic rod-hook plate in group A and wire anchor in group B. The load and axial torsion test of ankle joint were carried out by universal biomechanical testing machine.ResultsAccording to the anatomical characteristics, a plastic rod-hook plate was designed successfully. The biomechanical test results between animal and human specimens were consistent. There was a linear relationship between load and displacement in the ankle distal load test. The displacement when loaded to the maximum load was significantly lower in group A than in group B (P<0.05). The torsion angle and torque were significantly higher in group A than in group B when the internal fixation failed in the axial torsion test of the ankle joint (P<0.05), and the torsion angle was significantly smaller in group A than in group B when the torque was 1 N·m (P<0.05), and the maximum torque was also significantly higher in group A than in group B (P<0.05). However, there was no significant difference in torsion angle between the two groups in the maximum torque (P>0.05).ConclusionThe biomechanical properties of plastic rod-hook plate is obviously better than wire anchor, and the fixation of avulsion fracture with plastic rod-hook plate is easy to operate, which is expected to be used in the clinical treatment of minor avulsion fractures such as medial malleolus, lateral malleolus, base of the fifth metatarsal, and ulna styloid process.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
  • Early effectiveness of arthroscopic three-point suture technique in treatment of anterior cruciate ligament tibial eminence avulsion fracture

    Objective To investigate the early effectiveness of three-point suture technique in treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture by arthroscopy. Methods Between January 2016 and December 2017, 12 patients with ACL tibial eminence avulsion fractures underwent arthroscopic fixation of avulsion fractures with Ethibon suture using three-point suture technique. There were 9 males and 3 females, with an average of 36.4 years (range, 18-50 years). The fracture caused by traffic accident in 10 cases and sports in 2 cases. Among them, 1 patient was old fracture and 11 was fresh fracture. According to the modified Meyers-McKeever classification criteria, the fractures were rated as type Ⅲ in 7 cases and type Ⅳ in 5 cases. There were 2 cases of medial collateral ligament injury and medial meniscus injury. The preoperative International Knee Documentation Committee (IKDC) score was 37.9±4.7 and Lysholm score was 46.0±3.7. Results All operations completed smoothly. The operation time was 45-70 minutes (mean, 61.3 minutes). The incisions healed by first intention in all patients. The hospitalization stays ranged from 4 to 9 days (mean, 5 days). All patients were followed up 3-20 months (mean, 9.3 months). The anterior drawer test, Lachman test, and axis shift test in all patients were negative after operation. At last follow-up, the IKDC score was 89.7±2.5 and Lysholm score was 90.2±1.9, which were significantly higher than those before operation (t=–30.94, P=0.00; t=–33.03, P=0.00). At last follow-up, the X-ray films showed 9 cases of fracture anatomical reduction and 3 cases of almost anatomical reduction, and 12 cases of fracture healing. Conclusion For ACL tibial eminence avulsion fracture, arthroscopic three-point suture technique can effectively restore the stability of knee joint and obtain satisfactory early effectiveness.

    Release date:2019-06-20 03:12 Export PDF Favorites Scan
  • Treatment of tibial insertion avulsion fracture of anterior cruciate ligament involving anterior root of lateral meniscus with multi-point fixation with anchor and suture

    ObjectiveTo investigate the effectiveness of arthroscopic multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of anterior cruciate ligament (ACL) involving the anterior root of lateral meniscus (LM). Methods A retrospective analysis was conducted on the clinical data of 28 patients with tibial insertion avulsion fracture of ACL involving the anterior root of LM who were treated with arthroscopic multi-point fixation with anchor and suture between October 2017 and January 2023. There were 12 males and 16 females with the mean age of 26 years (range, 13-57 years). There were 20 cases of sports injury and 8 cases of traffic accident injury. In 2 cases of old fracture, the time from injury to operation was 45 days and 90 days, respectively; in 26 cases of fresh fracture, the time from injury to operation was 3-20 days (mean, 6.7 days). According to the Meyers-McKeever classification, there were 4 cases of type Ⅱ, 11 cases of type Ⅲ, and 13 cases of type Ⅳ. The preoperative Lysholm knee function score was 42.1±9.0, the International Knee Documentation Committee (IKDC) score was 40.0±7.3, and the Tegner score was 0.7±0.7. ResultsAll operations were successfully completed, and the incisions healed by first intention. All the 28 patients were followed up 5-60 months (mean, 20.4 months). During the follow-up, there was nocomplication such as infection, vascular or nerve injury, loosening or breakage of internal fixator, or stiffness of knee joint. Postoperative X-ray films showed satisfactory fracture reduction and firm fixation. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 10.3 weeks). At last follow-up, Lachman test and anterior drawer test were negative. At last follow-up, Lysholm knee function score was 92.4±5.5, IKDC score was 91.6±4.4, and Tegner score was 5.2±1.1, which significantly improved when compared with preoperative scores (t=−22.899, P<0.001; t=−29.870, P<0.001; t=−19.979, P<0.001). ConclusionMulti-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of ACL involving the anterior root of LM can not only fix the LM, but also effectively reduce and fix the avulsion fracture, which can obtain good effectiveness.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • Effectiveness analysis of minimally invasive safe approach to knee joint for treatment of avulsion fractures of tibial insertion of posterior cruciate ligament

    Objective To analyze the effectiveness of minimally invasive safe approach of the knee joint in the treatment of avulsion fractures of the tibial insertion of the posterior cruciate ligament (PCL). Methods The clinical data of 26 patients with avulsion fractures of tibial insertion of PCL treated with open reduction and internal fixation via minimally invasive safe approach of the knee joint between February 2019 and March 2022 were analyzed retrospectively. There were 18 males and 8 females with an average age of 45.5 years (range, 33-58 years). The causes of injury were traffic accident in 14 cases, falling from height in 7 cases, and sports injury in 5 cases. There were 15 cases of left knee and 11 cases of right knee. The preoperative Lysholm score of knee joint was 34.4±7.3 and the flexion range of motion of knee joint was (69±12)°. According to Meyers classification, there were 8 cases of type Ⅱ and 18 cases of type Ⅲ. The time from injury to operation ranged from 1 to 5 days, with an average of 2 days. ResultsThe operation time was 40-70 minutes, with an average of 55 minutes; the intraoperative blood loss was 10-30 mL, with an average of 15 mL. Delayed incision healing occurred in 1 case after operation, and the incision healed after conservative treatment, and the incisions of the other patients all healed by first intention. Postoperative X-ray films showed satisfactory fracture reduction. All 26 patients were followed up 3-30 months, with an average of 22 months. No complication such as neurovascular injury, infection, and knee extension disorder occurred after operation. X-ray films at 3 months after operation showed that all fractures healed without displacement of the fracture ends; the posterior drawer test was negative. At last follow-up, the flexion range of motion of knee joint was (120±9)°, the Lysholm score was 90.7±3.8, which were significantly improved when compared with those before operation (t=16.376, P<0.001; t=47.665, P<0.001). Conclusion The minimally invasive safe approach of the knee joint for the treatment of PCL tibial insertion avulsion fractures is easy to operate, with minimal surgical trauma, safe and reliable approach, and satisfactory recovery of knee joint function after operation.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Arthroscopic treatment of both anterior and posterior cruciate ligament tibial insertion avulsion fractures with suture and absorbable screw double fixation

    ObjectiveTo evaluate the effectiveness of arthroscopic suture and absorbable screw double fixation for both anterior and posterior cruciate ligament avulsion fractures of tibial insertions. MethodsBetween June 2006 and September 2013, 8 patients with anterior and posterior cruciate ligament avulsion fractures of the tibial eminence underwent arthroscopic treatment with suture and absorbable screw double fixation. There were 5 males and 3 females, with a mean age of 28.9 years (range, 18-43 years). The causes of injury included traffic accident in 5 cases and falling from height in 3 cases. The time from injury to operation was 3-10 days (mean, 6.2 days). The Lysholm knee score, International Knee Documentation Committee (IKDC) score, and Tegner rating scales were used to evaluated the knee function. ResultsPrimary healing of incision was obtained, without infection or deep vein thrombosis. The mean follow-up period was 42.4 months (range, 24 to 65 months). At 3 months after operation, X-ray films showed good reduction and healing of fracture. The anterior and posterior drawer tests were negative. The knee range of motion was normal (0-125°), and it recovered to preoperative level in 7 cases. The IKDC score, Tegner score, and Lysholm score were significantly improved to 90.4±5.2, 7.5±1.6, and 89.2±3.5 from preoperative 52.1±3.3, 3.3±1.0, and 51.9±3.5 respectively (t=-38.680, P=0.000; t=-39.520, P=0.000; t=-41.150, P=0.000). ConclusionA combined injury of anterior and posterior cruciate ligament avulsion fractures of tibial insertions is rare. Arthroscopic treatment with suture and absorbable screw double fixation is a useful technique to restore tibial avulsion injuries with well-documented radiographic healing, good clinical outcomes, and low complication rates.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF ULNAR COLLATERAL LIGAMENT AVULSION FRACTURE OF THUMB METACARP-OPHALANGEAL JOINT USING A COMBINATION OF Kirschner WIRE AND SILK TENSION BAND

    Objective To investigate the effectiveness of Kirschner wire combined with silk tension band in the treatment of ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint. Methods Between September 2008 and October 2011, 14 patients with ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint were treated using a combination of Kirschner wire and silk tension band. There were 8 males and 6 females, aged 23-55 years (mean, 40.8 years). The causes of injury were machinery twist injury in 5 cases, manual twist injury in 4 cases, falling in 4 cases, sports injury in 1 case. The time from injury to operation was 2 hours-14 days. All the patients presented pain over the ulnar aspect of the metacarpophalangeal joint of the thumb, limitation of motion, and joint instability with pinch and grip. The lateral stress testing of the metacarpophalangeal joint was positive. Function training was given at 2 weeks after operation. Results All incisions healed by first intention. The lateral stress testing of the metacarpophalangeal joint was negative. All the patients were followed up 6-18 months (mean, 13.1 months). The X-ray films showed good fracture reduction and healing with an average time of 7 weeks (range, 4-10 weeks). At last follow-up, the thumbs had stable flexion and extension of the metacarpophalangeal joint, normal opposition function and grip and pinch strengths. According to Saetta et al. criteria for functional assessment, the results were excellent in 11 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is an easy and simple method to treat ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint using Kirschner wire combined with silk tension band, which can meet the good finger function.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF TWO ARTHROSCOPIC DIFFERENT FIXATIONS FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

    Objective To compare the effectiveness of arthroscopic screw and suture fixations in treatment of anterior cruciate ligament tibial eminence avulsion fractures. Methods Between January 2002 and January 2009, 43 patients with freshanterior cruciate ligament tibial eminence avulsion fracture were treated, which were rated as types II and III according to Meyers- McKeever-Zaricznyj classification. Fractures were fixed with either screw (screw group, n=21) or nonabsorbable suture (suture group, n=22). There was no significant difference in sex, age, disease duration, and fracture type between 2 groups (P gt; 0.05). The range of motion (ROM) and Lysholm score were compared between 2 groups, and the knee stabil ity was evaluated based on the Lachman test and KT-2000 measurement. Results The operation time was 48-60 minutes (mean, 51.6 minutes) in the screw group, and 55-68 minutes (mean, 63.2 minutes) in the suture group, showing significant difference (t=4.645, P=0.032). Incisions healed by first intention and no compl ication occurred in 2 groups. All patients were followed up (5.7 ± 0.6) years in the screw group and (5.3 ± 0.5) years in the suture group. The fracture healed completely in both groups; the heal ing time was (3.3 ± 0.6) months in the screw group and (3.2 ± 0.4) months in the suture group, showing significant difference (t=3.723, P=0.019). Between the screw group and the suture group, no significant difference was found in ROM [(128.6 ± 10.1)° vs. (130.2 ± 14.1)°, P gt; 0.05] and Lysholm score (94.6 ± 14.5 vs. 95.1 ± 17.2, P gt; 0.05). The stabil ities based on KT-2000 measurement were also similar between 2 groups at last follow-up [(0.9 ± 0.3) mm vs. (1.0 ± 0.4) mm, P gt; 0.05]. Lachman test of 2 groups were negative. Conclusion Boththe screw and nonabsorbable suture fixation techniques for anterior cruciate l igament tibial eminence avulsion fracture (type II or III) have good results in terms of functional outcome and stabil ity. However, some patients show flexion contractures of 5° or 10°.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • ARTHROSCOPIC TREATMENT FOR TIBIAL EMINENCE AVULSION FRACTURE USING ABSORBABLE DOUBLE SUTURE ANCHORS

    Objective To investigate the outcomes of arthroscopic reduction and internal fixation of tibial eminence avulsion fracture using absorbable double suture anchors. Methods Between February 2007 and August 2009, 18 patients with tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation using absorbable doublensuture anchors. There were 12 males and 6 females with an average age of 30.6 years (range, 17-48 years). The disease causes were traffic accident injury in 4 cases, sport injury in 8 cases, and fall ing from height injury in 6 cases; the locations were left side in 7 cases and right side in 11 cases. The results of the anterior drawer test and Lachman test were positive. According to Meyers-McKeever classification, 10 cases were rated as type II, 7 as type III, and 1 as type IV fractures. The time from injury to treatment was 6-20 days (mean, 10.2 days). Results Incision healed primarily. All the patients were followed up 29.1 months (range, 13-43 months). The X-ray films showed good reduction of fracture immediately after operation and fracture heal ing at 3 months. At the last follow-up, the range of motion of knee was 0-130°. The results of Lachman test and anterior drawer test were negative in 18 cases and 16 cases, repectively; and the results of anterior drawer test were weakly positive in 2 cases. The mean Lysholm score was significantly improved from 53.9 ± 6.7 preoperatively to 91.6 ± 4.2 postoperatively (t=22.100, P=0.000). The Inter national knee Documentation Commitee (IKDC) 2000 subject score improved from 58.1 ± 3.7 preoperatively to 92.8 ± 5.9 postoperatively (t=20.700, P=0.000). Conclusion Arthroscopic treatment using absorbable double suture anchors for tibial eminence avulsion fracture can provide satisfactory reduction, stable fixation, and good heal ing of the avulsed fragment, which is a minimally-invasive, simple, and effective treatment for patients with tibial eminence avulsion fracture.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content