find Keyword "collimator" 5 results
  • Application of Liner-accelerator Two-degrade Collimator in the Treatment of Nasopharyngeal Carcinoma with Volumetric Modulated Arc Therapy

    ObjectiveCompare the two-degrade collimator (MLC) angle selection's impact on plan quality and operational efficiency for volumetric intensity-modulated radiotherapy (VMAT) in the treatment planning system, and to explore the scheme for treatment plan optimization. MethodsTwenty patients with nasopharyngeal carcinoma underwent the treatment between March and December 2013 were randomly selected and planned for SIBVMAT treatment with different parameters set in the range of 0-60°with 15°interval for collimator angles. Planned dose distribution to the target volumes, organs at risk, and monitor units were compared. ResultsAs the MLC angle increased, target conformal index and homogeneity index had a trend to became deteriorated. The optimal plans were 0°and 15°, while 45°and 60°plans gave poor protection for the organ at risk compare to other angle plans and the monitor units were significantly increased. ConclusionChange the MLC angle had visible impact on treatment plans,there was a trend to deteriorate with the MLC angle increased, but small changes in MLC angle range can theoretically reduce the influence from leakage radiation on the human body.

    Release date: Export PDF Favorites Scan
  • A review of progress of real-time tumor tracking radiotherapy technology based on dynamic multi-leaf collimator

    While radiation treatment to patients with tumors in thorax and abdomen is being performed, further improvement of radiation accuracy is restricted by the tumor intra-fractional motion due to respiration. Real-time tumor tracking radiation is an optimal solution to tumor intra-fractional motion. A review of the progress of real-time dynamic multi-leaf collimator (DMLC) tracking is provided in the present review, including DMLC tracking method, time lag of DMLC tracking system, and dosimetric verification.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • Design of longitudinal auto-tracking of the detector on X-ray in digital radiography

    One algorithm is designed to implement longitudinal auto-tracking of the the detector on X-ray in the digital radiography system (DR) with manual collimator. In this study, when the longitudinal length of field of view (LFOV) on the detector is coincided with the longitudinal effective imaging size of the detector, the collimator half open angle (Ψ), the maximum centric distance (emax) between the center of X-ray field of view and the projection center of the focal spot, and the detector moving distance for auto-traking can be calculated automatically. When LFOV is smaller than the longitudinal effective imaging size of the detector by reducing Ψ, the emax can still be used to calculate the detector moving distance. Using this auto-tracking algorithm in DR with manual collimator, the tested results show that the X-ray projection is totally covered by the effective imaging area of the detector, although the center of the field of view is not aligned with the center of the effective imaging area of the detector. As a simple and low-cost design, the algorithm can be used for longitudinal auto-tracking of the detector on X-ray in the manual collimator DR.

    Release date:2018-04-16 09:57 Export PDF Favorites Scan
  • Design and validation of calibration between tube focus spot and center plane of rotation in computed tomography system

    This study proposed a method to calibrate tube focus spot and the center plane of rotation in computed tomography system. In the method, the tube was rotated to 0° and 180° respectively, and then one metal jig with symmetric windows A and B was scanned at each position under the tube cool and static condition. According to the geometry of tube focus spot, aperture center of the collimator and jig, the distance between tube focus spot and the center plane of rotation were calculated with the X ray transmittance data after denoising, mean value and normalization. To verify the practicability and validity of the method, the tube focus spot in a 16 slices CT system (Brivo CT385, GE, China) was calibrated, and the result after calibration was validated by scanning a polaroid film. The validation result showed that the deviation between tube focal spot and center plane of rotation was 0.02 mm and was in the error range within ± 0.1 mm. The results of this study showed that, as a simple and low-cost design, the method could be used for fast calibration between tube focus spot and the center plane of rotation.

    Release date:2019-08-12 02:37 Export PDF Favorites Scan
  • Study on the sensitivity of a volumetric modulated arc therapy plan verification equipment on multi-leaf collimator opening and closing errors and its gamma pass rate limit

    To investigate the γ pass rate limit of plan verification equipment for volumetric modulated arc therapy (VMAT) plan verification and its sensitivity on the opening and closing errors of multi-leaf collimator (MLC), 50 cases of nasopharyngeal carcinoma VMAT plan with clockwise and counterclockwise full arcs were randomly selected. Eight kinds of MLC opening and closing errors were introduced in 10 cases of them, and 80 plans with errors were generated. Firstly, the plan verification was conducted in the form of field-by-field measurement and true composite measurement. The γ analysis with the criteria of 3% dose difference, distance to agreement of 2 mm, 10% dose threshold, and absolute dose global normalized conditions were performed for these fields. Then gradient analysis was used to investigate the sensitivity of field-by-field measurement and true composite measurement on MLC opening and closing errors, and the receiver operating characteristic curve (ROC) was used to investigate the optimal threshold of γ pass rate for identifying errors. Tolerance limits and action limits for γ pass rates were calculated using statistical process control (SPC) method for another 40 cases. The error identification ability using the tolerance limit calculated by SPC method and the universal tolerance limit (95%) were compared with using the optimal threshold of ROC. The results show that for the true composite measurement, the clockwise arc and the counterclockwise arc, the descent gradients of the γ passing rate with per millimeter MLC opening error are 10.61%, 7.62% and 6.66%, respectively, and the descent gradients with per millimeter MLC closing error are 9.75%, 7.36% and 6.37%, respectively. The optimal thresholds obtained by the ROC method are 99.35%, 97.95% and 98.25%, respectively, and the tolerance limits obtained by the SPC method are 98.98%, 97.74% and 98.62%, respectively. The tolerance limit calculated by SPC method is close to the optimal threshold of ROC, both of which could identify all errors of ±2 mm, while the universal tolerance limit can only partially identify them, indicating that the universal tolerance limit is not sensitive on some large errors. Therefore, considering the factors such as ease of use and accuracy, it is suggested to use the true composite measurement in clinical practice, and to formulate tolerance limits and action limits suitable for the actual process of the institution based on the SPC method. In conclusion, it is expected that the results of this study can provide some references for institutions to optimize the radiotherapy plan verification process, set appropriate pass rate limit, and promote the standardization of plan verification.

    Release date: Export PDF Favorites Scan