west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "computer tomography" 12 results
  • Application of incremental dynamic enhanced computer tomography in the diagnosis of solitary pulmonary nodules

    Objective To evaluate the value of incremental dynamic enhanced computer tomography (CT) in diagnosis of solitary pulmonary nodules (SPN). Methods The data of 42 cases with SPN who had undergone pulmonary lobectomy were collected retrospectively to find the relationship between character of preoperative dynamic enhanced CT image and postoperative pathologic result. Results All bronchogenic carcinoma showed significant enhancement after intravenous 100 ml iodinated contrast material. The average degree of enhancement of bronchogenic carcinoma during the time 85s and 135s after infusion was significantly different from that of tuberculoma and other benign lesions(Plt;0.05). Conclusion Dynamic enhanced CT is valuable in identifying the malignant nodules from benign nodules. Emphasis should be paid to the lymph nodes in the relative field with dynamic enhanced CT, which is beneficial to the diagnosis of SPN and it is an important predictor of the result of surgical treatment.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • Effect of MultiSlice Spiral Computer Tomography Combined with Serum Amyloid A Protein on Preoperative Rectal Cancer Staging

    摘要:目的: 探讨64排多层螺旋CT(MSCT)和血清淀粉样蛋白A(serum amyloid A protein, SAA)联合术前评估直肠癌在肿瘤分期诊断中的作用。 方法 :纳入经根治术治疗的直肠癌患者通过MSCT扫描进行评估,同时取患者静脉血测量术前SAA水平,行MSCT分期与MSCT和SAA联合分期以比较二者的诊断价值。 结果 :本研究纳入患者121例。MSCT检测T分期的准确度为851%。在评估淋巴结转移方面,MSCT和SAA联合分期的准确度为760%,明显高于MSCT分期(595%, 〖WTBX〗P lt;0001)。MSCT正确判断所有远处转移。同单一的MSCT检测相比,MSCT和SAA联合评估能显著的提高术前TNM分期的准确率(785% vs. 636%,〖WTBX〗P =0011)。 结论 :MSCT联合SAA检测比单一的MSCT检测显著提高了直肠癌术前肿瘤分期和淋巴结转移方面的准确度。这种新的术前评估方法的为肿瘤进展评估和术前治疗决策提供了更加可靠的信息。Abstract: Objective: To determine the role of combinative assessment of 64 multislice spiral computer tomography (MSCT) and serum amyloid A protein (SAA) in preoperative rectal cancer staging. Methods : Enrolled consecutive rectal cancer patients undergoing curative surgery were evaluated by MSCT scan. Meanwhile venous blood specimens were taken to measure preoperative SAA concentration. Both MSCT staging and MSCT plus SAA staging were performed to compare with each other. Results : The study population consisted of 121 patients. The accuracy of T staging was 851% for MSCT. The accuracy in evaluating lymph nodes metastases was 760% for MSCT plus SAA compared with 595% for MSCT alone (〖WTBX〗P lt;0001). All the distant metastases were correctly detected by MSCT. The method combining MSCT with SAA led to significant improvement on preoperative TNM staging compared with MSCT alone (785% vs. 636%, 〖WTBX〗P =0011). Conclusion : MSCT plus SAA showed greater accuracy than MSCT alone in rectal cancer staging and lymph node metastases. This novel strategy of preoperative evaluation appears to provide more accurate information on tumor progression and preoperative therapy decisionmaking.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Influence of Combinative Assessment of 64 Multi-Slice Spiral CT and Serum Amyloid A Protein onOperative Procedures’ Prediction of Lower Rectal Cancer

    Objective To determine the influence of combinative assessment of 64 multi-slice spiral computer tomography (MSCT) and serum amyloid A protein (SAA ) on the selection of operative procedures in lower rectal cancer.MethodsProspectively enrolled 130 patients diagnosed definitely as lower rectal cancer (distance of tumor to the dentate line ≤7 cm) at West China Hospital of Sichuan University from July 2007 to September 2008 were randomly assigned into two groups with 65 participants, respectively. In one group named MSCT+SAAgroup, both 64 MSCT and SAA combinative assessment were made for the preoperative evaluation. In another group named MSCT group, only the preoperative MSCT was made. Furthermore, the preoperative staging and predicted operation procedures were compared with postoperative pathologic staging and practical operation program, respectively.ResultsAccording to the criteria, 119 patients with colorectal cancer were actually included into MSCT+SAA group (n=58) and MSCT group (n=61). The baselines characteristics of two groups were basically identical. For MSCT+SAAgroup, the accuracies of preoperative staging T, N, M and TNM were 89.66%, 79.31%, 100% and 77.59%, respectively; For MSCT group, the corresponding rates were 86.89%, 70.49%, 100% and 65.57%, respectively. There was a statistically significant difference of the accuracy of prediction to operative procedures in two groups (93.10% vs. 80.33%, P=0.041). The clinical staging (P=0.001), preoperative T staging (P=0.000), M staging (P=0.016), TNM staging (P=0.013) and serum level of SAA (P=0.029) were related to the selection of operative procedures when analyzing the relationship between the operative procedures and multiple clinicopathologic factors in lower rectal cancer. ConclusionCombinative assessment of 64 MSCT and SAA could improve the accuracy of preoperative staging, thus provide higher predictive coincidence rate to operative procedures for surgeon.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Role of Multimodal Preoperative Evaluation System in Prediction to Operative Strategies for Lower and Middle Rectal Cancer: A Randomized Controlled Trial

    Objective To determine the role of multimodal preoperative evaluation (MPE) system of transrectal ultrasound (TRUS), 64 multi-slice spiral computer tomography (MSCT) and serum amyloid A protein (SAA) in assessment of preoperative staging and selection of operative procedures of the lower and middle rectal cancer in multi-disciplinary team. Methods Prospectively enrolled 150 patients, who were diagnosed definitely as lower and middle rectal cancer (distance of tumor to the dentate line ≤10 cm) at West China Hospital of Sichuan University from November 2008 to March 2009, randomly assigned into two groups. In one group named MPE group, MPE consisting of TRUS, MSCT and SAA were made for the preoperative evaluation. In another group named MSCT+SAA group, both MSCT and SAA were made preoperatively. Then, the preoperative staging and predicted operative procedures were compared with postoperative pathologic staging and practical operative procedures, respectively. Furthermore, the pooled data were analyzed for the correlative relationship between the choice of surgery strategy and clinicopathological factors. Results According to the criteria, 146 patients with lower and middle rectal cancer were randomly assigned into MPE group (n=74) and MSCT+SAA group (n=72). The baselines characteristics of two groups were statistically identical. For MPE group the accuracy of preoperative staging T, N, M and TNM were 94.6% (70/74), 85.1% (63/74), 100% (74/74) and 82.4% (61/74), respectively; For MSCT+SAA group the corresponding rates were 77.8% (56/72), 84.7% (61/72), 100% (72/72) and 81.9% (59/72), respectively. The analysis showed a statistically difference in the accuracy of preoperative T staging between two groups (P=0.003) while there was no statistically significant difference of the accuracies of preoperative N, M and TNM staging between two groups (Pgt;0.05). There wasn’t a statistically significant increasing of the accuracy of prediction to operative procedures in MPE group compared with MSCT+SAA group 〔95.9% (71/74) vs.88.9% (64/72), P=0.106〕. When analyzing the relationship between multiple clinicopathologic factors and the operative procedures of lower and middle rectal cancer, there were statistical correlations between the pathological T staging (r=0.216, P=0.009), N staging (r=0.264, P=0.001), TNM staging (r=0.281, P=0.001), serum level of SAA before operation (r=0.252, P=0.002) or the distance of tumor to the dentate line (r=-0.261, P=0.001) and the operative procedures. Conclusion MPE system could display the accurate preoperative staging for lower and middle rectal cancer, on which the prediction of operative procedures can rest convincingly.

    Release date:2016-09-08 11:04 Export PDF Favorites Scan
  • Randomized Controlled Trial of Preoperatively Combinative Assessment of Upper Rectal Cancer in Prediction to Operative Strategies

    Objective To determine the influence of combinative assessment of 64 multi-slice spiral computer tomography (MSCT) and serum amyloid A protein (SAA) on the selection of operative procedures of upper rectal cancer in multi-disciplinary team. Methods Prospectively enrolled 110 patients, who were diagnosed definitely as upper rectal cancer (distance of tumor to the dentate line gt;7 cm) at West China Hospital of Sichuan University from August 2007 to October 2008, randomly assigned into two groups. In one group named MSCT+SAA group, both MSCT and SAA combinative assessment were made for the preoperative evaluation. In another group named MSCT group, only MSCT was made preoperatively. Then, the pooled data were analyzed for the correlative relationship between the choice of surgery strategy and clinicopathologic factors. Furthermore, the preoperative staging and predicted operative procedures were compared with postoperative pathologic staging and practical operative procedures, respectively. Results According to the criteria, 106 patients with upper rectal cancer were randomly assigned into MSCT+SAA group (n=52) and MSCT group (n=54). The baseline characteristics of two groups were statistically identical. When analyzing the proportion of multiple clinicopathologic factors in different operative procedures of upper rectal cancer, there were statistical differences in the preoperative N staging (P=0.003), M staging (P=0.022), TNM staging (P=0.003), serum level of SAA (P=0.005) and general category of tumor (P=0.027). For MSCT+SAA group the accuracies of preoperative staging T, N, M and TNM were 84.6%, 86.5%, 100% and 86.5%, respectively; For MSCT group the corresponding rates were 83.3%, 2.9%, 100% and 64.8%, respectively. There were statistically significant differences accuracies of preoperative N staging and TNM staging (P=0.005, P=0.009, respectively) in two groups. There was a statistically significant difference of the accuracy of prediction to operative procedures in two groups (96.2% vs. 81.5%, P=0.017). Conclusion Combinative assessment of 64 MSCT and SAA could improve the accuracy of preoperative staging, and thus provide higher predictive coincidence rate to operative procedures for surgeon.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Influence of Combinative Assessment of 64 Multi-Slice Spiral Computer Tomography and Serum Amyloid A Protein on Surgery Strategy of Colon Cancer

     Objective To discuss the influence of combination of 64 multi-slice spiral computer tomography (MSCT) and serum amyloid A protein (SAA) for preoperative assessment on colon cancer surgery strategy.  Methods The examination data of 110 patients diagnosed definitely as colon cancer in the West China Hospital of Sichuan University from Nov. 2007 to Nov. 2008 were studied prospectively, and randomly assigned into the MSCT+SAA group and MSCT group, respectively. Both MSCT and SAA combinative assessment were made for preoperative evaluation in MSCT+SAA group, while only MSCT was made preoperatively in MSCT group. Furthermore, the preoperative staging and prediction of operative procedures were compared with postoperative pathologic staging and practical of operative procedures, respectively.  Results According to the inclusion criteria, 99 colon cancer patients were actually included into MSCT+SAA group (n=49) and MSCT group (n=50). The baseline characteristics of two groups were statistically identical. For MSCT+SAA group, The accuracies of preoperative staging T, N, M and TNM were 81.6%, 79.6%, 100% and 77.6%, respectively. For MSCT group, the corresponding rates were 82.0%, 60.0%, 98.0% and 62.0%, respectively. The difference of accuracies on staging N between two groups was observed statistically (χ2=4.498, P=0.034). There was also a statistically significant difference of the accuracy of prediction of operative procedures in MSCT+SAA group and MSCT group (95.9% vs. 82.0%, χ2=4.854, P=0.028). The preoperative staging N (P=0.008), M (P=0.010), TNM (P=0.009) and level of SAA (P=0.004) were related to the selection of operative procedures when analyzed the relationship between the operative procedures and multiple clinicopathologic factors in colon cancer.  Conclusion The strategy of the combinative assessment of MSCT and SAA could advance the accuracy of preoperative staging, thus serve surgeon the more accurate prediction to surgery strategy in colon cancer.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Randomized Controlled Trial of Combining MultiSlice Spiral Computer Tomography with Serum Amyloid A Protein or Fibrinogen on Rectal Cancer Surgical Decision Making

    Objective To determine the influence and significance of combinative assessment of 64 multi-slice spiral computer tomography (MSCT) with serum amyloid A protein (SAA) or fibrinogen (FIB) on the selection of operative procedures of rectal cancer under the multidisciplinary team. Methods Prospectively enrolled 240 patients diagnosed definitely as rectal cancer at West China Hospital of Sichuan University from February to June 2009 were randomly assigned into two groups. In one group named MSCT+SAA group, both MSCT and SAA combinative assessment were made for the preoperative evaluation. In another group named MSCT+FIB group, both MSCT and FIB combinative assessment were made for preoperative evaluation. Furthermore, the preoperative staging and predicted operation procedures were compared with postoperative pathologic staging and practical operation procedures, respectively, and the relationship between the choice of operation procedures and clinicopathologic factors was analyzed. Results According to the criteria, 234 patients were actually included into MSCT+SAA group (n=118) and MSCT+FIB group (n=116). The baseline characteristics of two groups were statistically similar (Pgt;0.05). For MSCT+SAA group, the accuracies of preoperative staging T, N, M and TNM were 72.9%, 83.1%, 100% and 80.1%, respectively. For MSCT+FIB group, the accuracies of preoperative staging T, N, M and TNM were 68.1%, 75.0%, 100% and 74.1%, respectively, and there was not a statistically significant difference (Pgt;0.05). There was also not a statistically significant difference of the accuracy of prediction to operative procedures in two groups (99.6% vs. 96.6%, Pgt;0.05). The preoperative T staging (P<0.001), N staging (P<0.001), TNM staging (P<0.001), serum level of SAA (P<0.001), serum level of FIB (Plt;0.001) and distance of tumor to the dentate line (P<0.05) were associated to the operative procedures. Conclusions Combinative assessment of MSCT and FIB could improve the accuracy of preoperative staging and operative procedures prediction, however, it may be not superior to MSCT plus SAA.

    Release date:2016-09-08 11:05 Export PDF Favorites Scan
  • Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer tomography

    This paper proposes a novel metal artifact reduction (MAR) algorithm for dental implants in kilovoltage computed tomography (kVCT) using megavoltage cone-beam computer tomography (MVCBCT). Firstly, two CT images were derived by scanning patient with dental implants using kVCT and MVCBCT. Metal image was derived by thresholding segmentation in kVCT. MVCBCT and kVCT images were fused to generate prior image which was forward projected to get surrogate sinogram of metal trace. The corrected image was generated by filtered backprojection (FBP) reconstruction in corrected sinogram. The results of proposed algorithm were compared with other frequently-used metal artifact reduction algorithm, such as normalized MAR (NMAR), normalized MAR using MVCBCT prior images (NMAR-MV), and linear interpolation MAR (LIMAR). The normalized root mean square deviation (NRMSD) and mean absolute deviation (MAD) were computed. The experiment showed that the proposed method removed serious metal artifacts without introducing new artifacts. The values of NRMSD and MAD for proposed method were the minimum in all methods. The values of NRMSD for NMAR, NMAR-MV, LIMAR and the proposed method were 21.0%, 22.1%, 41.9% and 17.0% respectively. And MAD values of them were 232, 235, 553, 205 HU, respectively. In conclusion, the proposed metal artifact reduction algorithm can successfully suppress metal artifacts for dental implants, and greatly improve the quality of CT image.

    Release date:2017-10-23 02:15 Export PDF Favorites Scan
  • The application of subjective assessment, two dimensional measurement and three dimensional measurement in solid component measurement of lung part-solid ground glass nodule

    Stage ⅠA lung adenocarcinoma presented as ground glass dominant on thin-section high-resolution CT scan is a special subtype of lung cancer. The characteristics of this subtype are quite different from the other patients, which presented as lower malignancy and better prognosis. Clinical, pathological and imaging studies have revealed that the proportion of the solid component in part-solid ground glass nodule is closely related with the pathological type and the prognosis of lung cancer. The methods for the assessment of the solid components in the ground glass nodule can be classified into three types, including subjective assessment, two dimensional measurement and three dimensional measurement. This review summarized the advantages and the limitations of these three methods. We also reviewed the clinical application of these techniques.

    Release date:2018-06-26 05:41 Export PDF Favorites Scan
  • Texture analysis based on CT images to differentiate atypical pancreatic solid pseudopapillary tumor and pancreatic adenocarcinoma: a preliminary study

    Objective To access the diagnostic performance of CT texture analysis to differentiate atypical pancreatic solid pseudopapillary tumor (SPT) from pancreatic ductal adenocarcinoma (PDAC). Methods CT images of 26 patients with pathologically proved atypical SPT and 52 patients with PDAC were analyzed. 3D regions of interest (ROIs) on arterial phase (AP) and portal venous phase (PVP) images were drawn by ITK-Snap software. A.K. software (GE company, USA) was used to extract texture features for the discrimination of atypical SPT and PDAC. After removing redundancy (by a correlation analysis through R software), texture features were selected by single-factor and multi-factor logistic regression, and logistic regression model was finally established. Receiver operating characteristic (ROC) analysis was performed to assess the diagnostic performance of single texture feature and logistic model. Results A total of 792 texture features [396 of AP, 396 of PVP] from AP and PVP CT images were obtained by A.K. software. Of these, 61 texture features (35 of AP, 26 of PVP) were selected by R software (result of correlation analysis showed that correlation coefficient >0.7). Two texture features, including MinIntensity and Correlation_AllDirection_offset1_SD, were selected to establish logistic model. The sensitivity and specificity of these 2 texture features were 71.15% and 76.92%, 63.46% and 76.92% respectively, the area under curve ( AUC) were 0.740 and 0.754 respectively. The model’s sensitivity and specificity were 73.08% and 80.77% respectively, the AUC value was 0.796. There was no significance among the model, MinIntensity, and Correlation_AllDirection_offset1_SD (P>0.05). Conclusions CT texture analysis of 3D ROI is a quantitative method for differential diagnosis of atypical SPT from PDAC.

    Release date:2018-10-11 02:52 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content