Objective To provide the evidence for anti-epidemic command and developing response plan through investigation on prophlactical disinfection in Deyang, the worst-hit areas after Wenchuan earthquake. Methods We used convenient sampling together with the report forms and the self-made questionnaire to collect information from 107 villages and 17 settlement spots for the disaster victims in 25 towns in Deyang disaster area. Results There were a total of 6 kinds of disinfectant, including the chlorine disinfectant, 2 kinds of peroxide disinfectant and 2 other types of disinfectant, which were delivered the Deyang disaster area through the National amp; Province CDC system allocation or the None-Goverment Organization donation. From May 17 to June 9, the large-scale preventive disinfection was carried out in the disaster area, covering tap water, the restroom and the latrine pit, trash, environment and sewage. All personnel who conducted the disinfection for prevention and public health in the villages and towns received the technical training for disinfection. Conclusion Various disinfectant types and difference specifications cause trouble in the training of manpower and the use of disinfectant. Preventive disinfection in the most serious disaster areas is better than in serious disaster areas. The main channel of obtaining the disinfectant is through the National amp; Province CDC. The daily-report system of the disinfected areas may monitor the progress of disinfectant use. The suitable disinfection may prevent the public health secondary disaster and protect the environment effectively.
In this study, silicone hand was disinfected by homemade touchable non-thermal plasma to simulate and evaluate its feasibility of application on human hand. Experimental results showed that there was no significant difference whenEscherichia coli (E. coli),Staphylococcus aureus (S. au),Staphylococcus albus (S. al), andPseudomonas aeruginosa (P. ae) were loaded on the silicone hand surface and treated with plasma. The efficiency of plasma disinfection was higher when the treatment time was prolonged or initial bacterial density was lower. When initial bacterial number was 1.0×106–1.0×107 CFU, the plasma disinfection process mainly occured in the first 5 s and more than 99% of bacteria could be disinfected. This study can provide guidelines for the development of a new plasma device for human hand disinfection.
ObjectiveTo investigate on preoperative hand-washing for analyzing the underlying problems, in purpose of preventing operation-related infection via strengthening the standardization of surgical hand-washing and hand-disinfection. MethodsFrom July to September 2014, surveillance video of pre-operative hand-washing was studied and analyzed. We randomly selected 100 subjects, and assessment was performed based on the self-made surgical hand-washing and hand-disinfection protocol. Grading was done strictly. The passing score was 60 or higher; a score of 70-79 meant good; and a score of 80-100 indicated excellence. ResultsIn the survey, 91 in the 100 subjects were qualified. Among the qualified subjects, there were 53% of excellence and 20% of good. The major problems included erroneous methods, step omissions, time lacking, pollution, wrong flushing method or dry-hand method, and insufficient washing time. ConclusionBased on the survey, the administration department is advised to strengthen the regulatory supervision and education training based on standard surgical hand-washing and hand-disinfection criteria, especially training interns and new staff, in purpose of reducing the incidence of operation-related infection and improving hospitalization management qualities.
ObjectiveTo investigate the problems in the use of quick-drying hand disinfectants and formulate intervention measures to improve the hand hygiene compliance of nursing staff.MethodsFrom February 2014 to June 2016, the hand hygiene compliance of nursing staff was continuously observed according to the hand hygiene observation table recommended by the World Health Organization. The questionnaire on the use of quick-drying hand disinfectants, which passed the reliability and validity test, was used to find out the reasons leading to the low compliance rate of hand hygiene among nurses, and pertinent interventions were formulated. From November 2016 to December 2017, intervention measures were gradually implemented throughout the hospital, and the hand hygiene compliance of nursing staff was continuously observed again. Then we compared the compliance rate of hand hygiene and the compliance rate of hygienic hand disinfection among nurses in the second quarter of 2016 (before intervention) with those in the last quarter of 2017 (after intervention).ResultsThe compliance rates of hand hygiene and hygienic hand disinfection among nurses before intervention were 62.15% and 49.77%, respectively, and those after intervention were 91.64% and 90.80%, respectively. The differences were statistically significant (P<0.05).ConclusionThe factors affecting the hand hygiene compliance of nursing staff are identified through questionnaires and targeted intervention measures have effectively improved the hand hygiene compliance rate of nursing staff.
ObjectiveTo evaluate the evidence of the experience with medical sewage treatment procedures in medical institutions in China. MethodsDatabases including CNKI, WanFang Data, PubMed, Web of Science, and EBSCO were electronically searched to collect studies on the medical sewage treatment process, flow, and specifications in medical institutions in China. We used the quality evaluation system to classify and grade the experiences based on the principles and methods of evidence-based science and performed a descriptive analysis. ResultsAfter the SARS pandemic in 2003, China systematically established and standardized the technical criteria of medical sewage treatment and discharge. Moreover, a prevention system for the epidemic using medical sewage was constructed, which guaranteed that the quality of medical sewage treatment and discharge would meet the criteria and protect the citizens, and the technical specifications of medical sewage treatment would progress and increase strictly. At present, medical sewage treatment in medical institutions in China was based on mechanical and biological methods, and disinfection was mainly performed using chlorine and its compounds, ozone, and ultraviolet light. ConclusionThe COVID-19 pandemic requires a higher quality of medical sewage treatment and discharge criteria for medical institutions in China. To meet these criteria, all medical institutions in China should check, replace, and update their old facilities; strengthen personnel training and effectively ensure the quality of medical sewage treatment.
ObjectiveTo evaluate the efficiency of hydrogen peroxide vapor (HPV) in disinfecting multidrug-resistant organisms (MDROs).MethodsWe searched Cochrane Library, PubMed, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang, China Science and Technology Journal Database for before-after studies or case-control studies or cohort studies evaluating efficiency of HPV and published from January 2010 to December 2020 (the time range was from January 2000 to December 2020 in the snowball searching). RevMan 5.4 and R 4.0.2 softwares were used for meta-analysis.ResultsA total of 9 studies were included, consisting of 8 before-after studies and 1 cohort study. Six studies evaluated positive rate of environmental samplings, meta-analysis revealed that HPV combined with manual cleaning disinfected the environment efficiently [relative risk (RR)=0.03, 95% confidence interval (CI) (0.01, 0.08), P< 0.000 01] and HPV was more efficient than manual cleaning [RR=0.04, 95%CI (0.02, 0.10), P< 0.000 01]. Three studies evaluated the hospital-acquired MDROs colonization/infection rates, and the results of the 3 studies were consistent, revealing that HPV could reduce hospital-acquired MDROs colonization/infection rates.ConclusionHPV is efficient in reducing MDROs contaminated surfaces and hospital-acquired infection rate.
ObjectiveTo systematically review the safety of hand disinfectants. MethodsPubMed, EMbase, The Cochrane Library, INAHTA, WanFang Data, CNKI and VIP databases were electronically searched to collect studies on the safety of hand disinfectants from inception to February 1st, 2021. Two reviewers independently screened the literature, extracted data and assessed the risk of bias of the included studies; then, a systematic review was conducted. ResultsA total of 50 studies were included. The reported adverse events were eye and nasal mucosal irritation, hand adverse events with skin itching, rash, erythema, edema and so on. A total of 29 brands such as 3M Avagard and 26 ingredients such as ethanol were reported to be related to the above adverse events. Hand disinfectants containing glycerin, silicone oil, vitamin B, plant extracts and other emollients could reduce the incidence of adverse events. ConclusionCurrent evidence shows that hand disinfectants containing emollients and free from ethanol, chlorhexidine and other ingredients are related to fewer adverse events. Due to the limited quality and quantity of the included studies, more high-quality studies are needed to verify the above conclusion.
Endoscopic retrograde cholangiopancreatography is one of the main methods for the diagnosis and treatment of biliary tract and pancreatic diseases. Compared with other digestive endoscopes, duodenoscopy has a special structure. Since the outbreaks of nosocomial infections caused by the transmission of multidrug-resistant organism through duodenoscopy in 2010, the reprocessing and design of digestive endoscopes represented by duodenoscopy have faced new challenges. This article reviews the international advances in duodenoscopy reprocessing in the past 10 years including the structural characteristics of duodenoscope, related infection outbreak cases, outbreak control measures, and the use of disposable duodenoscopy, so as to provide guidance and reference for the duodenoscopy reprocessing and related nosocomial infections prevention and control work in China.
The quality of disinfectant, disinfection devices and disposable medical devices is closely related to the patients' safety. Hospital infection management department must carry out the audit responsibilities for qualification documents of disinfectant, disinfection devices and disposable medical devices, to guarantee legality, safety and effectiveness of products used in hospital. This paper mainly introduces the implementation of qualification documents audit in West China Hospital, Sichuan University, including system construction, process reengineering, documents audit scope and key points, and document management.
With the development of medical diagnosis and treatment technology, ultrasound examination has been widely used in clinical practice, but it also faces certain safety hazards. If the ultrasound probe is not effectively disinfected after use, it may be contaminated by pathogenic bacteria transmitted from blood, mucous membranes, genital or rectal secretions, thus becoming a carrier for the transmission of pathogenic bacteria among patients. In addition, the frequent use of ultrasound probe and coupling agent is also an important factor affecting the occurrence of hospital infections. Multiple studies at home and abroad have shown that incomplete cleaning and disinfection of medical ultrasound probe can lead to hospital infection incidents, thereby affecting patient safety and medical quality. Exploring effective disinfection methods and disinfection effects of ultrasound probe is of great significance for hospital infection prevention and control. Therefore, this article provides a review of research related to disinfection of medical ultrasound probe.