west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "elastography" 22 results
  • Diagnostic value of shear wave elastography combined with vascular endothelial growth factor B and hemoglobin A1c in early diabetic peripheral neuropathy

    Objective To analyze the diagnostic value of shear wave elastography (SWE) combined with vascular endothelial growth factor B (VEGF-B) and hemoglobin A1c (HbA1c) in early diabetic peripheral neuropathy (DPN). Methods A total of 100 patients with type 2 diabetes mellitus (T2DM) admitted to Mianyang Central Hospital between October 2020 and October 2023 were selected and divided into a T2DM with DPN group (n=31) and a T2DM without DPN group (n=69) based on the presence or absence of DPN. Additionally, 50 healthy individuals from the same hospital’s health examination center were included as a healthy control group. The basic clinical characteristics, mean elasticity (Emean) values of the left and right median and tibial nerves, serum VEGF-B, and HbA1c levels were compared among the three groups. The diagnostic efficacy of SWE, VEGF-B, and HbA1c for DPN was evaluated using receiver operating characteristic (ROC) curves, and Pearson correlation analysis was performed to assess the relationships between median/tibial nerve Emean and VEGF-B/HbA1c. Results The Emean values of the left and right median nerves, Emean values of the left and right tibial nerves, serum VEGF-B, and HbA1c levels in the T2DM with DPN group were significantly higher than those in the T2DM without DPN group and the healthy control group (P<0.05). The Emean values of the left and right median and tibial nerves, Emean values of the left and right tibial nerves, and HbA1c level in the T2DM without DPN group were significantly higher than those in the healthy control group (P<0.05), while no significant difference was observed in serum VEGF-B level between the T2DM without DPN group and the healthy control group (P>0.05). The area under the ROC curve for the combined diagnosis of DPN using SWE, VEGF-B, and HbA1c was 0.859 [95% confidence interval (0.828, 0.955)]. The sensitivity of the combined diagnosis (93.72%) was significantly higher than that of individual diagnoses (78.82%, 75.39%, and 71.05%, respectively; P<0.05), while the specificity (88.64%) showed no significant difference compared to individual diagnoses (80.18%, 78.96%, and 82.88%, respectively; P>0.05). Positive correlations were observed between median/tibial nerve Emean and VEGF-B/HbA1c levels (r=0.428, 0.395, 0.416, and 0.416, respectively; P<0.05). Conclusions Elevated median/tibial nerve Emean, serum VEGF-B, and HbA1c levels are closely associated with DPN. The combination of SWE, VEGF-B, and HbA1c improves diagnostic sensitivity for DPN, demonstrating significant clinical value.

    Release date:2025-05-26 04:29 Export PDF Favorites Scan
  • Transient Elastography: Progress in Predicting The Prognosis of Hepatic Surgery

    ObjectiveTo summarize the progress of transient elastography in predicting the prognosis of hepatic surgery. MethodsThe related literatures were reviewed. ResultsLiver stiffness can be measured by using transient elastography.In patients with hepatocarcinoma, the liver stiffness measurements are higher, the more likely they are to have surgical complications and hepatocarcinoma recurrence.Liver transplant recipients with higher liver stiffness measurements tend to have higher acute rejection and hepatitis C recurrence rates. ConclusionTransient elastography can evaluate hepatic functional reserve to help improve the outcome of hepatic surgery.

    Release date: Export PDF Favorites Scan
  • Value of ultrasound real-time elastography in differentiating benign from malignant solid thyroid nodules

    ObjectiveTo explore value of ultrasound real-time elastography (RTE) technology for identification of benign and malignant solid thyroid nodules.MethodsA retrospective analysis was performed on 125 patients with thyroid nodules who underwent ultrasound RTE in this hospital from February 2018 to August 2019. All patients underwent RTE on the basis of conventional ultrasound. The ultrasound elasticity contrast index (ECI) was used as the evaluation index and the pathological examination result was used as the gold standard. The receiver operating characteristic (ROC) curve analysis was used to evaluate the value of ECI in the identification of benign and malignant solid thyroid nodules. Logistic regression analysis was used to analyze the influencing factors of ECI.ResultsAmong the 125 patients with solid thyroid nodules, 51 were malignant nodules, 74 were benign nodules. The ECI value of patients with benign thyroid nodules was lower than that of patients with malignant nodules (2.71±0.83 versus 3.42±1.14, t=–4.030, P<0.001). The result of ROC analysis showed that the cutoff value of ECI to distinguish benign and malignant solid thyroid nodules was 3.07, area under curve of ROC was 0.806 [95%CI (0.717, 0.894), P<0.001], sensitivity was 80.3%, specificity was 70.4%. The multivariate logistic regression analysis showed that the thyroid nodules with diffuse lesions, calcification, and maximum nodule diameter ≥1 cm were the risk factors for elevated ECI values (P<0.05). For the solid thyroid nodules without diffuse lesions, without calcification, and maximum nodule diameter <1 cm, ECI had the higher sensitivity, specificity, accuracy, and positive predictive value for the differential diagnosis of benign and malignant thyroid nodules (all exceed 80%), but these indexes were lower (under 60%) for the differential diagnosis of solid thyroid nodules with diffuse diseases, with calcification, and maximum nodule diameter ≥1 cm.ConclusionsECI obtained by ultrasound RTE can be used to differentiate solid thyroid nodules from benign ones. The presence or absence of diffuse lesions, calcification, and maximum nodule diameter are the influencing factors for ECI to differentiate solid thyroid nodules. In clinical diagnosis, it should be paid attention to the comprehensive analysis of the above factors.

    Release date:2021-04-25 05:33 Export PDF Favorites Scan
  • Evaluation of Coagulation in Orthotopic Liver Transplantation with Thrombelastography

    ObjectiveTo evaluate the changes in thrombelastography(TEG) during orthotopic liver transplantation (OLT) in Chinese. MethodsTwentyfive patients with cirrhosis of liver undergoing OLT were studied. They were composed of two groups: cirrhosis group (n=15) and liver neoplasm group (n=10). Anesthesia was induced with propofol 1.5-2 mg/kg,fentanyl 3-5 μg/kg and vecuronium 0.1 mg/kg and maintained with isoflurane or enflurane inhalation.The operation was divided into three phases: ① before operation and preanhepatic phase (120 min after operation was started), ② 30 min after liver was removed,③ 5 min before reperfusion and 5 min,15 min,30 min,60 min and 120 min after reperfusion.In 8 patients among the 25 patients heparinasecelite TEG was measured 5 min after reperfusion in addition to celite TEG.If there was significant differences in traces between the two TEG measurements,an intravenous bolus of 50-75 mg protamine was given and the heparinasecelite TEG was repeated.The measured variables included the r (reaction) time,representing the rate of initial fibrin formation K (coagulation) time, alpha angles (α) reflecting fibrinplatelet interaction, MA (maximal amplitude) indicating qualitative platelet function and percent fibrinolysis at 60 min. ResultsIn cirrhosis group changes in TEG occurred after liver was removed and in earlier period after reperfusion, while in liver neoplasm group changes in TEG were found in earlier period after reperfusion as compared with preoperative value.At 5 min after reperfusion there were significant differences in TEG (r,K,α and MA) values between celite and heparincelite TEG (P<0.01). ConclusionDuring OLT coagulation disorder occurs mainly at anhepatic and early reperfusion phase.

    Release date:2016-08-28 04:49 Export PDF Favorites Scan
  • Evaluation of pelvic floor muscle structure and function by transluminal dual plane ultrasound

    Objective To explore the feasibility of transluminal dual plane ultrasound (TDPU) in evaluating the structure and function of pelvic floor muscle. Methods Non anorectal diseases patients who visited the Department of Medical Ultrasound, West China Hospital of Sichuan University, medical staff and medical staff’s relatives volunteers between May and November 2022 were selected. According to the criteria for ultrasound diagnosis of pelvic organ prolapse (POP) and the pelvic organ prolapse quantification (POP-Q) scoring criteria, the subjects were divided into normal group and POP group. The changes of the thickness of the left and right puborectalis muscle (PRM), the internal anal sphincter (IAS) and the external anal sphincter (EAS) at 3-, 6- and 9-o’clock, the depth and height of the perineal body (PB) were compared, and the changes of the elastic Young’s modulus of PRM, EAS and PB were compared through real-time shear wave elastography. Results A total of 192 subjects were included, including 140 in the normal group and 52 in the POP group. There were statistically significant differences between the POP group and the normal group in terms of gestational frequency, parity, and history of vaginal delivery (P<0.05). There was no statistically significant difference in age, body mass index, menopausal history, and neonatal weight between the two groups (P>0.05). Under the condition of resting and maximum anal constriction, the thickness of PRM on the left and right sides of POP group was not significantly different from that of the normal group (P>0.05), but the elastic Young’s modulus of PRM on the left and right sides were lower than that of the normal group (P<0.05). At resting and maximum anal constriction, there was no significant difference in IAS thickness between the POP group and the normal group at 3-, 6- and 9-o’clock (P>0.05). At resting and maximum anal constriction, the thickness of deep and subcutaneous parts of EAS at 6-o’clock and the subcutaneous part of EAS at 9-o’clock in the POP group were smaller than those in the normal group (P<0.05). At resting and maximum anal constriction, the elastic Young’s modulus of EAS at 3-, 6- and 9-o’clock were lower than those in the normal group (P<0.05). There was no significant difference in the depth and height of PB between the POP group and the normal group at resting and maximum anal constriction (P>0.05). The elastic Young’s modulus of PB in the POP group was lower than that of the normal group (P<0.05). Under the condition of maximum anal constriction, the thickness of deep and subcutaneous parts of EAS at 3-o’clock in the POP group were lower than those in the normal group (P<0.05). Conclusion TDPU can quantitatively evaluate the structure and function of pelvic floor muscle through different states of resting and maximum anal constriction, and also can provide ultrasonic basis for the diagnosis and treatment of female pelvic floor dysfunction diseases.

    Release date:2023-04-24 08:49 Export PDF Favorites Scan
  • The diagnostic value of real-time tissue elastography in differentiating benign and malignant breast tumors

    ObjectiveTo explore the value of ultrasound real-time tissue elastography in the differential diagnosis between benign and malignant breast lesions.Methods A total of 131 cases of patients with breast lesions who underwent ultrasound examination in the People’s Hospital of Guangan City between December 2010 and December 2015 were enrolled as the research object. The patients took conventional color Doppler ultrasound diagnosis firstly, and then took ultrasound real-time tissue elastography diagnosis. The lesions were scored with improved 5-scoring system respectively. By the strain ratio measure method equipped with the ultrasonic machine, strain ratio of the lesion was calculated, with 3.08 as the cut-off pont. The results were campared with the pathologic diagnosis.ResultsThere were 182 breast lumps in the 131 patients. The conventional ultrasound examination detected 128 benign lesions and 54 malignant lesions. By ultrasound real-time tissue elastography examination, there were 121 benign tumors and 61 malignant tumors. For the benign tumors, the elasticity imaging score was 1.74±0.81, and the elastic strain rate ratio was 1.83±1.22; for the malignant tumors, the elasticity imaging score was 4.45±0.59, and the elastic strain rate ratio was 8.68±5.58. The 182 breast lumps were all removed by surgical resection, and the pathologic examination showed there were 121 benign lesions and 61 malignant lesions. The accuracy, sensitivity and specificity of conventional ultrasonic diagnosis of breast malignant lesions was 76.4%, 59.0% and 85.1%, respectively; while the indexes of ultrasound real-time tissue elastography diagnosis of breast malignant lesions was 96.7%, 95.1% and 97.5%, respectively, and the differences were statistically significant (P<0.05).ConclusionReal-time tissue elastography is helpful in the differential diagnosis between malignant and benign breast lesions.

    Release date:2017-07-21 03:43 Export PDF Favorites Scan
  • Application value of shear wave elastography in evaluating the quadriceps femoris lesions in patients with chronic obstructive pulmonary disease

    Objective To explore the clinical value of shear wave elastography in the evaluation of quadriceps femoris lesions in patients with chronic obstructive pulmonary disease (COPD). Methods Fifty-eight COPD patients who were admitted to Chengdu First People’s Hospital and 55 healthy controls were included in the study between August 2021 and February 2022. The thickness, circumference, cross-sectional area and Young's modulus of quadriceps femoris in all subjects were measured using shear wave elastography combined with conventional two-dimensional ultrasound. The differences in ultrasound parameters between the two groups were compared, and the correlation between each ultrasound parameter and clinical evaluation indicators (modified British Medical Research Council Scale, COPD Assessment Test, six-minute walk test, and five-time sit-to-stand test) was analyzed. Results Young’s modulus values of the quadriceps femoris muscle were smaller in the COPD group than those in the healthy control group [COPD Group: rectus femoris 6.72 (6.22, 7.36) kPa, vastus medialis 6.25 (5.82, 6.79) kPa, vastus lateralis 6.94 (6.17, 7.48) kPa; healthy control group: rectus femoris 11.40 (10.23, 12.11) kPa, vastus medialis 10.77 (9.62, 11.42) kPa, vastus lateralis 11.14 (10.42, 12.52) kPa]. The differences were statistically significant (all P<0.05). The Young's modulus value of the rectus femoris muscle correlates with the aforementioned clinical evaluation indicators, with positive correlation with six-minute walk distance and negative correlation with COPD Assessment Test, modified British Medical Research Council Scale, five-time sit-to-stand time (P<0.05). Quadriceps thickness, circumference, and cross-sectional area measured by conventional two-dimensional ultrasound were not significantly different between the two groups, nor were there significant correlations between each parameter and clinical parameters (P>0.05). In addition, shear wave elastography has good reproducibility in the measurement of Young's modulus in quadriceps. Conclusions Shear wave elastography can identify quadriceps lesions earlier than conventional two-dimensional ultrasound in COPD patients, and there is a significant correlation between its measurements and the clinical condition of COPD patients. Shear wave elastography may provide a simple and noninvasive method for clinical evaluation of quadriceps femoris lesions in COPD patients.

    Release date:2022-11-29 04:54 Export PDF Favorites Scan
  • The Initial Study of Real-time Shear Wave Elastography in Parotid and Submaxillary Gland of Healthy Adults

    ObjectiveTo study the Young's modulus obtained by the real-time shear wave elastography (SWE) in healthy adults' parotid gland and submaxillary gland and to explore the probable factors affecting the Young's modulus, such as bilateral parotid and submaxillary gland, sex, age, height and weight. MethodsThere were 35 healthy volunteers who underwent SWE in parotid gland and submaxillary gland between December 3 and 18, 2013. The difference of Young's modulus in bilateral parotid and submaxillary gland, and the modulus values of different sex, age, height and weight groups were also compared. ResultsThe Young's modulus of parotid gland was (8.14±1.78) kPa, and the Young's modulus of submaxillary gland was (11.52±2.34) kPa. The differences of Young's modulus between the two sides of parotid gland and submaxillary gland were not statistically significant (P>0.05); the differences of Young's modulus of parotid and submaxillary gland between different sex, age, height and weight groups had no statistical significance, either (P>0.05). ConclusionThe real-time shear wave elastography can be applied to evaluate the elasticity of parotid and submaxillary gland and to lay the foundation for further diagnosis of salivary lesions.

    Release date: Export PDF Favorites Scan
  • Diagnostic value of ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer: a systematic review

    ObjectiveTo systematically review the diagnostic value of the ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer.MethodsWe electronically searched the databases including The Cochrane Library, PubMed, CNKI, WanFang Data, VIP, MedaLink and CBM for studies about diagnostic value of the ultrasonographic elastography in the differential diagnosis of axillary lymph nodes in breast cancer from inception to October 2016. Two reviewers independently screened literature, extracted data and assessed the risk of bias of the included studies. Then meta-analysis was performed using MetaDisc 1.4 software.ResultsA total of 9 studies involving 735 lymph nodes were included. The results of meta-analysis showed that, the pooled sensitivity, pooled specificity, pooled positive likelihood ratio, pooled negative likelihood ratio and DOR were 0.82 (95%CI 0.78 to 0.86), 0.76 (95%CI 0.72 to 0.81), 3.32 (95%CI 2.57 to 4.27), 0.25 (95%CI 0.20 to 0.31), and 14.77 (95%CI 10.20 to 21.38), respectively. The AUC of the SROC curve was 0.8741.ConclusionUltrasonographic elastography has high sensitivity and specificity in the differential diagnosis of axillary lymph nodes in breast cancer, which indicates that it can be used to diagnosis axillary lymph nodes in breast cancer.

    Release date:2017-08-17 10:28 Export PDF Favorites Scan
  • Value of Ultrasonographic Elastography in Differential Diagnosis of Benign/Malignant Thyroid Nodules in China: A Meta-Analysis

    ObjectiveTo systematically review the clinical value of ultrasonographic elastography (UE) for the differential diagnosis of benign/malignant thyroid nodules. MethodsWe comprehensively searched the databases including The Cochrane Library (Issue2, 2013), PubMed, EMbase, CNKI, WanFang Data, Medalink, VIP and CBM from inception to the December of 2013, for including clinical research reports of determining thyroid nodules using ultrasonographic elastography. Literature screening according to the inclusion and exclusion criteria, data extraction and methodological quality assessment were completed by two reviewers independently. Then Meta-DiSc software (version 1.4) was used for pooling analysis. ResultsA total of 35 studies including 4 127 patients were included. The results of metaanalysis showed that, specificity, sensitivity, positive likelihood radio, negative likelihood radio and diagnostic odds ratio (DOR) were 0.89 (0.88 to 0.90), 0.88 (0.86 to 0.90), 6.37 (5.44 to7.47), 0.13 (0.11 to 0.16) and 58.72 (43.12 to 79.98), respectively; and the area under SROC curve (AUC) was 0.936 9. ConclusionCurrent evidence shows that ultrasonographic elastography has fairly high sensitivity (88%) and specificity (89%) in differential diagnosis of benign/malignant thyroid nodules. The positive rate in the malignant thyroid group is 58.72 times higher that in benign thyroid cancer with better efficacy in differential diagnosis, so ultrasonographic elastography is of effective and feasible diagnostic value for thyroid benign/malignant nodules.

    Release date: Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content