  • Application of computational fluid dynamics in the aortic root reconstruction

    ObjectiveTo investigate the application of computational fluid dynamics (CFD) in hemodynamic evaluation of aortic root reconstruction.MethodsThe clinical data of 1 patient with severe aortic valve stenosis was analyzed. Enhanced CT images were used as the original data, and professional software was used to reconstruct the three-dimensional (3D) model and fluid mechanics simulation of the aorta (including preoperative, postoperative and ideal conditions).ResultsThe 3D reconstruction model could directly present the distribution of valve calcification and the dilatation of the ascending aorta. The remodeled sinotubular junction and sinus structure were observed in the model under postoperative and ideal conditions. The improvement of ascending aorta dilatation was evaluated statistically by the diameter distribution before and after surgery. CFD simulation showed that the area of high flow velocity, pressure intensity and wall shear stress before surgery were consistent with the expansion area of the ascending aorta, and the restricted blood flow acceleration was observed at the angle between the arch and the descending aorta. In the ideal condition, the streamline of blood at the descending aorta was more stable and flat compared with preoperative or postoperative conditions, and there was no obvious abnormal high pressure and high wall shear stress area in the ascending aorta. The cardiopulmonary bypass time was 106 min, of which the aortic cross-clamp time was 60 min. The cardiac echocardiography indicated that the aortic valve worked well, and the peak systolic blood velocity was 1.7 m/s. The length of hospital stay after surgery was 12 d, including 2 d in ICU. The ventilator use time was 11.6 h. The patient did not have any remarkable discomfort during the 1-year follow-up.ConclusionCFD can be used to evaluate anatomic and hemodynamic abnormalities before aortic root reconstruction surgery. Postoperative reconstruction simulation can be performed again to evaluate the surgical effect, and meanwhile, virtual improvement can be tried for the unresolved problems to accumulate diagnosis and treatment experience, so as to provide patients with more accurate and personalized diagnosis and treatment procedure.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Simulation analysis of adaptability of large airborne negative pressure isolation cabin to aviation conditions

    In order to solve the problems of difficult test, high cost and long cycle in the development of large-scale airborne negative pressure isolation system, the simulation analysis of negative pressure response characteristics is carried out around various aviation conditions such as aircraft ascending, leveling and descending, especially rapid decompression, based on the computational fluid dynamics (CFD) method. The results showed that the isolation cabin could achieve –50 Pa pressure difference environment and form a certain pressure gradient. The exhaust air volume reached the maximum value in the early stage of the aircraft’s ascent, and gradually decreased with the increase of altitude until it was level flying. In the process of aircraft descent, the exhaust fan could theoretically maintain a pressure difference far below –50 Pa without working; Under the special condition of rapid pressure loss, it was difficult to deal with the rapid change of low pressure only by the exhaust fan, so it was necessary to design safety valve and other anti-leakage measures in the isolation cabin structure. Therefore, the initial stage of aircraft ascent is the key stage for the adjustment and control of the negative pressure isolation system. By controlling the exhaust air volume and adjusting parameters, it can adapt to the change of low pressure under normal flight conditions, form a relatively stable negative pressure environment, and meet the needs of biological control, isolation and transport.

    Release date:2025-08-19 11:47 Export PDF Favorites Scan
  • Hemodynamics simulation and analysis of left coronary artery aneurysms with concomitant stenosis

    The hemodynamic parameters in arteries are difficult to measure non-invasively, and the analysis and prediction of hemodynamic parameters based on computational fluid dynamics (CFD) has become one of the important research hotspots in biomechanics. This article establishes 15 idealized left coronary artery bifurcation models with concomitant stenosis and aneurysm lesions, and uses CFD method to numerically simulate them, exploring the effects of left anterior descending branch (LAD) stenosis rate and curvature radius on the hemodynamics inside the aneurysm. This study compared models with different stenosis rates and curvature radii and found that as the stenosis rate increased, the oscillatory shear index (OSI) and relative residence time (RRT) showed a trend of increase; In addition, the decrease in curvature radius led to an increase in the degree of vascular curvature and an increased risk of vascular aneurysm rupture. Among them, when the stenosis rate was less than 60%, the impact of stenosis rate on aneurysm rupture was greater, and when the stenosis rate was greater than 60%, the impact of curvature radius was more significant. Based on the research results of this article, it can be concluded that by comprehensively considering the effects of stenosis rate and curvature radius on hemodynamic parameters, the risk of aneurysm rupture can be analyzed and predicted. This article uses CFD methods to deeply explore the effects of stenosis rate and curvature radius on the hemodynamics of aneurysms, providing new theoretical basis and prediction methods for the assessment of aneurysm rupture risk, which has important academic value and practical guidance significance.

    Release date: Export PDF Favorites Scan
  • Progress on Diagnosis and Treatment of Congenital Tracheal Stenosis

    Congenital tracheal stenosis (CTS) is a rare but potentially life-threatening disease which results in congnital airway lesion. CTS is often associated with cardiovascular anomalies and presented with a wide spectrum of symptoms. CTS has challenged pediatric surgeons for decades. Various classic approaches and new techniques, including computational fluid dynamics, tissue-engineering trachea, and 3D printing have been proposed for diagnosis and treatment of CTS. This review provides a snapshot of the main progress of diagnosis and treatment of CTS.

    Release date: Export PDF Favorites Scan
  • Application advances in the computational fluid dynamics in tissue engineering

    ObjectiveTo review the advances in the computational fluid dynamics (CFD) in tissue engineering.MethodsThe latest research of CFD applied to tissue engineering were extensively retrieved and analyzed, the optimization of bioreactor design and the simulation of fluid dynamics and cell growth kinetics during tissue regeneration in vitro were mainly reviewed.ResultsThe simulation and predictive capabilities of CFD can provide important guidance for the optimization of bioreactor design, and the cultivation of engineering tissue. The accuracy of model prediction results can be further improved by combining with experimental research.ConclusionAs a new and effective research tool, CFD has its unique advantages in the application of tissue engineering. However, a more comprehensive and accurate simulation of the whole process of tissue regeneration still needs further studies.

    Release date:2021-06-30 03:55 Export PDF Favorites Scan
  • Hemodynamic study of personalized Stanford type B aortic dissection based on computational fluid dynamics

    Objective To establish a personalized Stanford type B aortic dissection numerical simulation model, and using computational fluid dynamics (CFD) numerical simulation to obtain the hemodynamic behavior and law of the type B aortic dissection at different stages of development. Methods Based on the theory of three-dimensional model reconstruction, we used CT images of a patient with type B aortic dissection in the Xiamen Cardiovascular Hospital of Xiamen University, relevant medical image processing software to reconstruct a personalized aortic three-dimensional model, and CFD to reconstruct the model which was simulated in fluid mechanics. Results The three-dimensional reconstruction model could intuitively observe the changing trend of the false cavity at different stages of the dissection development. Through fluid mechanics simulation, the blood flow rate, pressure, wall shear stress, vascular wall Von Mises stress and other parameters at different stages of the dissection development were obtained. Conclusion The hemodynamic behavior and law of relevant parameters in the development stage of aortic dissection are analyzed. The combination of the values of relevant parameters and clinical medical detection and diagnosis can well predict the development of the disease, and finally provide more theories and methods for the scientific diagnosis of aortic dissection.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
  • Noninvasive numerical simulation of coronary fractional flow reserve based on lattice Boltzmann method

    In order to investigate the application of lattice Boltzmann method (LBM) in the numerical simulation of computed tomography angiography-derived fractional flow reserve (FFRCT), an idealized narrowed tube model and two coronary stenosis arterymodels are studied. Based on the open source code library (Palabos), the relative algorithm program in the development environment (Codeblocks) was improved. Through comparing and analyzing the results of FFRCT which is simulated by LBM and finite element analysis software ANSYS, and the feasibility of the numerical simulation of FFRCT by LBM was verified . The results show that the relative error between the results of LBM and finite element analysis software ANSYS is about 1%, which vertifies the feasibility of simulating the coronary FFRCT by LBM. The simulation of this study provides technical support for developing future FFRCT application software, and lays the foundation for the calculation of clinical FFRCT.

    Release date:2018-08-23 03:47 Export PDF Favorites Scan
  • Influence of Angle Variation between Right Hepatic Vein and Inferior Vena Cava on Inferior Vena Cava Diaphragm

    Computational fluid dynamics was used to investigate the effect of the pathogenesis of membranous obstruction of inferior vena cava of Budd-Chiari syndrome with various angles between right hepatic vein and inferior vena cava. Mimics software was used to reconstruct the models from magnetic resonance imaging (MRI) angiograms of inferior vena cava, right hepatic vein, middle hepatic vein and left hepatic vein, and 3DMAX was used to construct the models of 30°, 60°, 90° and 120° angles between right hepatic vein and inferior vena cava, which was based on the reconstructed models.The model was conducted with clinical parameters in terms of wall shear stress distribution, static pressure distribution and blood velocity. The results demonstrated that the differences between wall shear stress and static pressure had statistical significance with various angles between right hepatic vein and inferior vena cava by SPSS. The pathogenesis of membranous obstruction of inferior vena cava had a correlation with the angles between right hepatic vein and inferior vena cava.

    Release date: Export PDF Favorites Scan
  • Analysis and Computational Fluid Dynamics Simulation of Hemodynamic Influences Caused by Splenic Vein Thrombosis

    This paper aims to analyze the impact of splenic vein thrombosis (SVT) on the hemodynamic parameters in hepatic portal vein system. Based on computed tomography (CT) images of a patient with portal hypertension and commercial software MIMICS, the patient's portal venous system model was reconstructed. Color Doppler ultrasound method was used to measure the blood flow velocity in portal vein system and then the blood flow velocities were used as the inlet boundary conditions of simulation. By using the computational fluid dynamics (CFD) method, we simulated the changes of hemodynamic parameters in portal venous system with and without splenic vein thrombosis and analyzed the influence of physiological processes. The simulation results reproduced the blood flow process in portal venous system and the results showed that the splenic vein thrombosis caused serious impacts on hemodynamics. When blood flowed through the thrombosis, blood pressure reduced, flow velocity and wall shear stress increased. Flow resistance increased, blood flow velocity slowed down, the pressure gradient and wall shear stress distribution were more uniform in portal vein. The blood supply to liver decreased. Splenic vein thrombosis led to the possibility of forming new thrombosis in portal vein and surroundings.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
  • Numerical Assessment of Impeller Features of Centrifugal Blood Pump Based on Fast Hemolysis Approximation Model

    The impeller profile, which is one of the most important factors, determines the creation of shear stress which leads to blood hemolysis in the internal flow of centrifugal blood pump. The investigation of the internal flow field in centrifugal blood pump and the estimation of the hemolysis within different impeller profiles will provide information to improve the performance of centrifugal blood pump. The SST κ-ω with low Reynolds correction was used in our laboratory to study the internal flow fields for four kinds of impellers of centrifugal blood pump. The flow fields included distributions of pressure field, velocity field and shear stress field. In addition, a fast numerical hemolysis approximation was adopted to calculate the normalized index of hemolysis (NIH). The results indicated that the pressure field distribution in all kinds of blood pump were reasonable, but for the log spiral impeller pump, the vortex and backflow were much lower than those of the other pumps, and the high shear stress zone was just about 0.004%, and the NIH was 0.0089.

    Release date: Export PDF Favorites Scan