find Keyword "hemocompatibility" 3 results
  • Hemocompatibility of Polyoxymethylene Used for Bileaflet Heart Valve

    The possibility of polyoxymethylene (POM) as heart valve leaflet material was investigated by comparing the hemocompatibility with that of 316L stainless steel and low-temperature isotropic pyrolytic carbon (LTIC). Surface hydrophobicity was characterized by water contact angle measurement.Platelet adhesion, APTT/PT/TT and hemolysis rate tests were applied for evaluating hemocompatibility. The results showed that POM was hydrophobic and had a low hemolytic rate, adhesion amount and activation degree of platelets on POM surface were less than 316L stainless steel, and was similar to LTIC. This research pointed out potential application of POM as heart valve leaflets.

    Release date: Export PDF Favorites Scan
  • Structural control and characterization of hierarchically structured fibrous scaffolds

    ObjectiveTo prepare hierarchically structured fibrous scaffolds with different morphologies, and to explore the additional dimensionality for tuning the physicochemical properties of the scaffolds and the effect of their hemocompatibility and cytocompatibility.MethodsElectrospinning poly (e-caprolactone) (PCL)/polyvinylpyrrolidone (PVP) bicomponent fibers (PCL∶PVP mass ratios were 8∶2 and 5∶5 respectively), and the surface porous fibrous scaffolds were prepared by extracting PVP components. The scaffolds were labeled PCL-P8 and PCL-P5 respectively according to the mass ratio of polymer. In addition, shish-kebab (SK) structured scaffolds with different kebab sizes were created by solution incubation method, which use electrospun PCL fibers as shish while PCL chains in solution crystallizes on the fiber surface. The PCL fibrous scaffolds with smooth surface was established as control group. The hierarchically structured fibrous scaffolds were characterized by field emission scanning electron microspore, water contact angle tests, and differential scanning calorimeter (DSC) experiments. The venous blood of New Zealand white rabbits was taken and hemolysis and coagulation tests were used to characterize the blood compatibility of the scaffolds. The proliferation of the pig iliac artery endothelial cell (PIEC) on the scaffolds was detected by cell counting kit 8 (CCK-8) method, and the biocompatibility of the scaffolds was evaluated.ResultsField emission scanning electron microscopy showed that porous morphology appeared on the surface of PCL/PVP bicomponent fibers after extracting PVP. In addition, SK structure with periodic arrangement was successfully prepared by solution induction, and the longer the crystallization time, the larger the lamellar size and periodic distance. The contact angle and DSC measurements showed that when compared with smooth PCL fiber scaffolds, the crystallinity of PCL surface porous fibrous scaffolds and PCL-SK fibrous scaffolds increased, while the hydrophobicity of PCL-SK fibrous scaffolds increased, but the hydrophobicity of PCL porous scaffolds did not change significantly. The hemolysis test showed that the hemolysis rate of PCL surface porous fibrous scaffolds and PCL-SK fibrous scaffolds was higher than that of PCL fibrous scaffolds. According to American Society of Materials and Tests (ASTM) F756-08 standard, all scaffolds were non-hemolytic materials and were suitable for blood contact materials. Coagulation test showed that the coagulation index of PCL surface porous fibrous scaffolds and PCL-SK fibrous scaffolds was higher than that of PCL fibrous scaffolds at 5 and 10 minutes of culture. CCK-8 assay showed that both hierarchically structured fibrous scaffolds were more conducive to PIEC proliferation than PCL fibrous scaffold.ConclusionBased on electrospinning technology, solution-induced and blend phase separation methods can be used to construct multi-scale fiber scaffolds with different morphologies, which can not only regulate the surface physicochemical properties of the scaffolds, but also have good blood compatibility and biocompatibility. The hierarchically structured fibrous scaffolds have high application potential in the field of tissue engineering.

    Release date:2019-05-06 04:46 Export PDF Favorites Scan
  • Hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment

    ObjectiveTo study the hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment. MethodsFresh bovine pericardium was treated with glutaraldehyde or non-glutaraldehyde after adipose tissue was removed. To evaluate the hemocompatibility of the two bioprosthetic heart valve materials, hemolysis test, in vitro fibrinogen adsorption experiment, platelet adhesion experiment, thrombin-antithrombin complex (TAT) test, complement activation assay and ex vivo circulation experiment were performed. ResultsThe hemolysis test results demonstrated that both of the materials showed hemolytic rates lower than 5%. The results of TAT test and complement activation assay showed no statistical differences among the two materials and the blank control group. Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment showed significantly decreased fibrinogen adsorption, platelet adhesion and thrombosis. ConclusionCompared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment show better hemocompatibility.

    Release date: Export PDF Favorites Scan