  • Comparison of two methods for hemodynamic assessment in children with tetralogy of Fallot after radical surgery

    Objective To explore the hemodynamic assessment after radical surgery in children with tetralogy of Fallot (TOF) by both echocardiography and Mostcare monitor. Methods Clinical data of 63 children with TOF who underwent radical surgery in our hospital from February 2016 to June 2018 were retrospectively analyzed, including 34 males and 29 females, aged 6-24 (9.82±5.77) months. There were 19 patients undergoing transannular patch reconstruction of the right ventricular outflow tract (a transannular patch group) while 44 patients retained the pulmonary valve annulus (a non-transannular patch group) . The echocardiography and Mostcare monitor parameters were recorded and brain natriuretic peptide was tested at the time points of 0, 8, 12, 24 and 48 hours after operation (T 0, T 1, T 2, T 4) to analyze their correlations and the change trend at different time points after radical surgery. Results The left ventricular ejection fraction at T 1 (43.49%±3.82%) was lower than that at T 0 (48.29%±4.55%), T 2 (45.83%±3.69%), T 3 (53.76%±4.43%) and T 4 (60.54%±3.23%, P<0.05). The cardiac index at T 1 (1.85±0.35 L·min−1·m−2) was lower than that at T 0 (2.11±0.38 L·min−1·m−2), T 2 (2.07±0.36 L·min−1·m−2), T 3 (2.42±0.37 L·min−1·m−2) and T 4 (2.82±0.42 L·min−1·m−2, P<0.05). The cardiac circulation efficiency at T1 (0.19±0.05) was lower than that at T 0 (0.22±0.06), T 2 (0.22±0.05), T 3 (0.28±0.06) and T 4 (0.34±0.06, P<0.05). The right ventricular two-chambers view fraction area change at T 1 (23.17%±3.11%) was lower than that at T 0 (25.81%±3.74%), T 2 (25.38%±3.43%), T 3 (30.60%±4.50%) and T 4 (36.94%±5.85%, P<0.05). The pulse pressure variability was the highest at T 0 (18.76%±3.58%), followed by T 1 (14.81%±3.32%), T 2 (12.44%±2.94%), T 3 (10.39%±2.96%) and T 4 (9.18%±1.92%, P<0.05). The blood brain natriuretic peptide was higher at T 1 (846.67±362.95 pg/ml) than that at T 0 (42.60±18.06 pg/ml), T 2 (730.95±351.09 pg/ml), T 3 (510.98±290.39 pg/ml) and T 4 (364.41±243.56 pg/ml, P<0.05). There was no significant difference in left ventricular ejection fraction, cardiac circulation efficiency and heart index between the two groups (P>0.05). The right ventricular two-chambers view fraction area change of the transannular patch group was significantly lower than that of the non-transannular patch group at each time point (P<0.05). The blood brain natriuretic peptide and pulse pressure variability of the transannular patch group were significantly higher than those of the non-transannular patch group (P<0.05). Left ventricular ejection fraction was positively correlated with cardiac index (r=0.637, P=0.001) and cardiac circulation efficiency (r=0.462, P=0.001) while was significantly negatively correlated with blood brain natriuretic peptide (r=–0.419, P=0.001). Conclusion Both methods can accurately reflect the state of cardiac function. Mostcare monitor has a good consistency with echocardiography. Using transannular patch to recontribute right ventricular outflow tract in operation has more influence on right ventricular systolic function. The Mostcare monitor can guide the hemodynamic management after surgery in real time, continuously and accurately.

    Release date:2019-03-29 01:35 Export PDF Favorites Scan
  • Application of cardiac assist device and its biomechanics research for heart failure

    As an important means of treating heart failure (HF), cardiac assist device has been widely used in clinic. This paper reviews the application status, existing problems and future development trend of cardiac assist devices, including the classification of cardiac assist devices, representative research achievements and indications of the assist devices. It also summarizes the biomechanical indexes of the heart and the new approaches and methods for treating heart failure, as well as the hemodynamic studies of cardiac assist devices in recent years. The research findings provide references for further optimization of cardiac assist device structure and clinical application of the device.

    Release date:2020-02-18 09:21 Export PDF Favorites Scan
  • Clinical efficacy of overall repair technique for rheumatic mitral valve lesions: A retrospective study in a single center

    Objective To investigate the clinical efficacy of mitral valve repair technique in the treatment of rheumatic mitral valve lesions. Methods The clinical data of patients diagnosed with rheumatic mitral valve lesions and undergoing mitral valve repair under extracorporeal circulation in our department from 2021 to 2022 were retrospectively analyzed. Results A total of 100 patients were collected, including 78 females and 22 males with an average age of 52 years. There were no secondary open heart or death in the whole group. Extracorporeal circulation time was 136.3±33.1 min, aortic cross-clamping time was 107.6±27.5 min, ventilator use time was 12.9±5.9 h, ICU stay was 2.6±1.4 d, and vasoactive medication use was 823.4±584.4 mg. Before and after the surgery, there were statistical differences in the left ventricular end diastolic diameter, left atrial end systolic diameter, effective mitral valve orifice area, shortening rate of left ventricular short axis, mitral E-peak blood flow velocity, mean mitral transvalvular pressure difference, mitral pressure half-time, and cardiac function graded by New York Heart Association (P<0.05). While there was no statistical difference in left ventricular ejection fraction or left ventricular end-diastolic volume (P>0.05). Conclusion Overall repair of rheumatic mitral valve lesions can significantly improve the cardiac function and hemodynamics of the patients, and is a good choice for patients with rheumatic mitral valve lesions.

    Release date:2024-05-28 03:37 Export PDF Favorites Scan
  • Anesthesia of lung transplant recipients

    [Abstract]The number of lung transplantation is gradually increasing worldwide, which brings new challenges to the multi-disciplinary team of lung transplantation. The prognosis of lung transplant recipients is seriously affected by the pathophysiological state of specific lung diseases and perioperative risk factors. It is of great significance for these patients to optimize perioperative management according to these factors. Recently, several expert consensus have been published regarding anesthesia management of lung transplantation. Based on the current evidence and clinical practice of West China Hospital, this review summarizes the key points of anesthesia management for lung transplant recipients to guide anesthesiologists' clinical practice.

    Release date:2023-01-18 06:43 Export PDF Favorites Scan
  • Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

    Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • Measurement Method of Arterial Shear Stress of Rats Model Based on Ultrasonic Particle Imaging Velocimetry

    The development and progression of atherosclerosis and thrombosis are closely related to changes of hemodynamics parameters. Ultrasonic pulse wave Doppler technique is normally used for noninvasively blood flow imaging. However, this technique only provides one-dimensional velocity and depends on the angle between the ultrasound beam and the local velocity vector. In this study, ultrasonic particle image velocimetry method was used to assess whole field hemodynamic changes in normal blood vessels. By using the polynomial fitting method, we investigated the velocity gradient and assessed the shear in different blood flow velocity of 10 healthy rats. It was found that using four polynomial fitting could result in optimal measurement results. The results obtained by ultrasonic particle image velocimetry accorded with the results obtained using Doppler technique. The statistical average of cyclical vessel wall shear stress was positively related to the locational mean velocity. It is proven that ultrasonic particle image velocimetry method could be used to assess directly the real-time whole field hemodynamic changes in blood vessels and was non-invasively, and should be a good prosperous technique for monitoring complex blood flow in stenotic arteries.

    Release date: Export PDF Favorites Scan
  • Advance in hybrid repair of chronic thoracoabdominal aortic dissecting aneurysm

    Surgical intervention for chronic thoracoabdominal aortic dissecting aneurysms (cTAADA) is regarded as one of the most challenging procedures in the field of vascular surgery. For nearly six decades, open repair predominantly utilizing prosthetic grafts has been the treatment of choice for cTAADA. With advances in minimally invasive endovascular technologies, two novel surgical approaches have emerged: total endovascular stent-graft repair and hybrid procedures combining retrograde debranching of visceral arteries with endovascular stent-graft repair (abbreviated as hybrid procedure). Although total endovascular stent-graft repair offers reduced trauma and quicker recovery, limitations persist in clinical application due to hostile anatomical requirements of the aorta, high costs, and the lack of universally available stent-graft products. Hybrid repair, integrating the minimally invasive ethos of endovascular repair with visceral artery debranching techniques, has increasingly become a significant surgical modality for managing thoracoabdominal aneurysms, especially in cases unsuitable for open surgery or total endovascular treatment due to anatomical constraints such as aortic tortuosity or narrow true lumens in dissections. Recent enhancements in hybrid surgical approaches include ongoing optimization of visceral artery reconstruction strategies based on hemodynamic analyses, and exploration of the comparative benefits of staged versus concurrent surgical interventions.

    Release date:2024-06-20 05:33 Export PDF Favorites Scan
  • Visualization and Quantitative Analysis of the Blood Flow Fields in Aortic Arch by Vector Flow Mapping in Normal Human Bodies

    To visualize and quantify the hemodynamics in the aortic arch in normal individuals, we used velocity distribution, retrograde flow, vortex formation, and mean energy loss (mEL) at different cardiac cycles in our study. We performed Vector flow mapping (VFM) analysis by using echocardiography in 87 healthy volunteers. The results showed that ① in different sections of the aortic arch, a skewed peak flow velocity (Vp) always appeared in the period of rapid ejection but in different distribution. The systolic flow in the entire aortic arch rose rapidly from near-zero at the point of iso-volumetric contraction to the peak velocity at the period of rapid ejection, and then decreased gradually; ② In the period of iso-volumetric relaxation, retrograde flow and vortex were observed in all subjects in the inner wall of the entire aortic arch; and ③ The change rule of mEL in the entire aortic arch was similar to that of flow velocity. VFM can provide insights into the intra-aortic arch flow patterns, and offer essential fundamentals about flow features associated with common aortic diseases.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • Effect of colloid priming on blood pressure in the first hour in critically ill patients receiving continuous renal replacement therapy

    Objective To investigate and compare the effects of succinylated gelatin injection and saline priming on the first hour blood pressure in critically ill patients receiving continuous renal replacement therapy (CRRT). Methods Inpatients who received continuous venous-venous dialysis filtration therapy in the intensive care unit of West China Hospital of Sichuan University between January and May 2024 were selected. The patients were randomly divided into an experimental group (colloidal solution group) and a control group (crystalloid solution group) in a 1∶1 ratio. The colloidal solution group used succinylated gelatin injection as the priming solution, and used the dual connection method to draw blood to the machine. The patient’s systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate at 10 minutes before and 0, 1, 3, 5, 10, 30 and 60 minute after CRRT initiation, the name and dosage of vascular compression drugs pumped intravenously at 0, 30 and 60 minutes, and the liquid inlet and outlet in the first hour were monitored and recorded. The crystalloid solution group used normal saline as the priming solution, and the rest of the methods were the same as those of the colloidal solution group. Two groups of patients were compared for changes in blood pressure and heart rate during the first hour of CRRT, as well as the incidence of hypotension. Results A total of 208 patients were included, with 104 cases in each group. There was no significant difference in baseline data between the two groups (P>0.05). At 3 minutes after CRRT, the systolic blood pressure of the crystalloid solution group was lower than that of the colloidal solution group [(122.56±23.82) vs. (129.43±25.46) mm Hg (1 mm Hg=0.133 kPa); t=−2.005, P=0.046]. There was no statistically significant difference in diastolic blood pressure, mean arterial pressure, or heart rate between the two groups at different time points (P>0.05). The intra group comparison results showed that the systolic blood pressure of the crystalloid solution group decreased compared to before at 1, 3, 5, and 10 minutes after CRRT (P<0.05), while the diastolic blood pressure and mean arterial pressure decreased compared to before at 3, 5, and 10 minutes after the start of CRRT (P<0.05); there was no statistically significant difference in blood pressure of the colloidal solution group among different time points after the start of CRRT (P>0.05). The heart rate of the crystalloid solution group was higher at 10 minutes after the start of CRRT than at 3 minutes after CRRT (P=0.045); 60 minutes after the start of CRRT, the heart rate in the colloidal solution group was lower than that 0 minutes after CRRT (P=0.032); there was no statistically significant difference between the two groups at other time points within each group (P>0.05). On the first hour of CRRT, there was a statistically significant difference in the incidence of hypotension between the two groups [33 cases (31.7%) vs. 18 cases (17.3%); χ2=5.845, P=0.016]. Conclusions The use of colloidal solution pre-flushing is more advantageous to improving the decrease in blood pressure in the first hour of CRRT in severe patients than crystalloid solution group pre-flushing. And it can reduce the incidence of hypotension in the first hour of CRRT in severe patients.

    Release date:2025-03-31 02:13 Export PDF Favorites Scan
  • Application of hemodynamic optimization in the design of artificial heart

    Heart failure is one kind of cardiovascular disease with high risk and high incidence. As an effective treatment of heart failure, artificial heart is gradually used in clinical treatment. Blood compatibility is an important parameter or index of artificial heart, and how to evaluate it through hemodynamic design and in vitro hemolysis test is a research hotspot in the industry. This paper first reviews the research progress in hemodynamic optimization and in vitro hemolysis evaluation of artificial heart, and then introduces the research achievements and progress of the team in related fields. The hemodynamic performance of the blood pump optimized in this paper can meet the needs of use. The normalized index of hemolysis obtained by in standard vitro hemolysis test is less than 0.1 g/100 L, which has good hemolysis performance in vitro. The optimization method described in this paper is suitable for most of the development of blood pump and can provide reference for related research work.

    Release date:2021-02-08 06:54 Export PDF Favorites Scan