Objective To explore effectiveness of minimally invasive internal fixation with locking plates for mid-shaft clavicle fractures. Methods Between October 2022 and August 2023, 28 patients with mid-shaft clavicle fractures were treated by minimally invasive internal fixation with locking plates. There were 10 males and 18 females with a mean age of 46.2 years (range, 18-74 years). The fractures were caused by traffic accident in 16 patients, sports-related injury in 7 patients, and other injuries in 5 patients. According to Robinson classification, the fractures were classified as type 2A1 in 1 case, type 2A2 in 6 cases, type 2B1 in 15 cases, and type 2B2 in 6 cases. The interval between fracture and operation ranged from 5 hours to 21 days (median, 1.0 days). The pain visual analogue scale (VAS) score was 8.1±1.6. The VAS score at 3 days after operation and the occurrence of complications after operation were recorded. During follow-up, X-ray films were re-examined to observe the healing of the fracture; the shoulder joint function was evaluated according to the Constant-Murley score at 6 months, and the length of the incision scar (total length of the distal and proximal incisions) was measured. ResultsAll operations were successfully completed without any subclavian vascular or nerve damage. All incisions healed by first intention. The VAS score was 1.2±0.7 at 3 days after operation, and there was a significant difference in VAS score between pre- and post-operation (t=8.704, P<0.001). At 1 week after operation, the patient’s shoulder was basically painless, and they resumed normal life. All patients were followed up 12-20 months (mean, 13.3 months). X-ray films showed that the bone callus began to form at 2-4 months after operation (mean, 2.7 months). There was no delayed healing or non healing of the fracture, and no loosening or fracture of the internal fixators during follow-up. At 6 months after operation, the mean total incision length was 1.5 cm (range, 1.1-1.8 cm); no patient complained of numbness or paresthesia on subclavicular region or anterior chest wall. The Constant-Murley score of shoulder joint function was 93-100 (mean, 97.6). Conclusion Minimally invasive internal fixation with locking plates is a good surgical method for treating mid-shaft clavicle fractures, with simple operation, minimal trauma, good postoperative results, and high satisfaction.
ObjectiveTo review the research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate. MethodsThe domestic and foreign literature about the proximal humeral fracture treated with locking plate was extensively reviewed. The incidence of screw penetration and risk factors were summarized from both primary and secondary screw penetrations, and the reasons of the intra-articular screw penetration and the technical solutions to avoid the penetration were analyzed. ResultsThe incidence of intra-articular screw penetration is about 11%-30%, which includes primary and secondary screw penetrations. The primary screw penetration is related to improper operation, inaccurate measurement, and “Steinmetz solid” effect, which results in inadequate fluoroscopy and blind zone. The secondary screw penetration is related to the loss of reduction and varus, collapse, and necrosis of the humeral head. The risk factors for intra-articular screw penetration include the bone mass density, the fracture type, the quality of fracture reduction, the applied location, number, and length of the plate and screws, and whether medial column buttress is restored. Improved fracture reduction, understanding the geometric distribution of screws, good intraoperative fluoroscopy, and reconstruction of medial column buttress stability are the key points for success. ConclusionThe risk of the intra-articular screw penetration in the proximal humeral fractures treated with locking plates is still high. Follow-up studies need to further clarify the cause and mechanism of screw penetration, and the risk factors that lead to screw penetration, in order to effectively prevent the occurrence of this complication.
Objective To summarize the method and effectiveness of open reduction and internal fixation in the treatment of 4 cases of bipolar clavicle dislocations. Methods Between June 2017 and June 2022, 4 patients with bipolar clavicle dislocations were admitted. There were 3 males and 1 female. The age ranged from 27 to 63 years, with an average age of 45 years. There were 2 cases of crushing injury of mine car, 1 case of traffic accident injury, and 1 case of heavy object injury. The time from injury to operation was 3-7 days, with an average of 5.0 days. The sternoclavicular joint dislocations were classified as Grade Ⅱ in 1 case and type Ⅲ in 3 cases, and anterior dislocation in 3 cases and posterior dislocation in 1 case. The acromioclavicular joint dislocations were classified as Tossy type Ⅱ in 2 cases and type Ⅲ in 2 cases. After open reduction, the sternoclavicular joint and acromioclavicular joint were fixed with lateral malleolus locking titanium plate and clavicular hook plate, respectively. ResultsAll operations were successfully completed without vascular or nerve injury. All incisions healed by first intention. All patients were followed up 12-18 months, with an average of 14 months. At last follow-up, the shoulder joint functions were rated as excellent in 3 cases and good in 1 case according to Rockwood score. During follow-up, there was no loosening of internal fixator or fracture. The internal fixators were removed in all patients at 5-7 months after operation (mean, 6 months), and no re-dislocation occurred after removal. Conclusion For bipolar clavicle dislocation, open reduction combined with lateral malleolus locking titanium plate fixation of the sternoclavicular joint and clavicle hook plate fixation of the acromioclavicular joint can achieve good effectiveness. It has the advantages of simple operation, high safety, firm fixation, and fewer complications, and the shoulder function recovers well.
Objective To probe into the effectiveness of vertical compression of locking plate combined with hollow screws in the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. MethodsThe clinical data of 128 patients with Sanders type Ⅱ and Ⅲ calcaneal fractures who were admitted between March 2019 and April 2022 and met the selection criteria were retrospectively analyzed. Among them, 65 patients were treated with locking plate combined with hollow screw vertical compression (study group), and 63 patients were treated with simple locking plate (control group). There was no significant difference in baseline data between the two groups (P>0.05), such as gender, age, fracture side and Sanders classification, cause of injury, time from injury to operation. The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded and compared between the two groups. Before operation and at 12 months after operation, the American Orthopaedic Foot and Ankle Association (AOFAS) score (including total score, pain score, functional score, and alignment score) was used to evaluate the recovery of foot function, and imaging indicators such as calcaneal width, calcaneal height, calcaneal length, Böhler angle, and Gissane angle were measured on X-ray films. ResultsAll patients were followed up 12 months after operation. There was no significant difference in operation time, intraoperative blood loss, hospital stay, and fracture healing time between the two groups (P>0.05). Poor wound healing occurred in 1 case in the study group and 2 cases in the control group. At 12 months after operation, there was no significant difference between the two groups in the pre- and post-operative difference of calcaneal length, calcaneal height, Gissane angle, and Böhler angle (P>0.05). However, the pre- and post-operative difference in calcaneal width in the study group was significantly higher than that in the control group (P<0.05). The pre- and post-operative difference of AOFAS total score in the study group was significantly higher than that in the control group (P<0.05), and further analysis showed that the pre- and post-operative difference of pain and function scores in the study group were significantly higher than those in the control group (P<0.05), while there was no significant difference in the pre- and post-operative difference of force score between the two groups (P>0.05). ConclusionCompared with simple locking plate treatment, the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures with vertical compression of locking plate combined with hollow screws can more effectively improve the width of the subtalar calcaneal articular surface, avoid peroneal longus and brevis impingement, reduce pain, and increase the range of motion of the subtalar joint, and the effectiveness is better.
Objective To analyze the effectiveness of flexible internal fixation with locking plate for distal femoral fractures. Methods Between January 2015 and June 2016, 21 cases of distal femoral fractures were treated. There were 5 males and 16 females with an average age of 62 years (range, 32-88 years). Injury was caused by falling in 14 cases, by traffic accident in 5 cases, and by falling from height in 2 cases. The fractures located at the left side in 13 cases and the right side in 8 cases. Twenty cases were fresh closed fractures and 1 case was open fracture. According to AO/Association for the Study of Internal Fixation (AO/OTA) typing, there were 5 cases of type 33-A1, 3 of type 33-A2, 8 of type 33-A3, 2 of type 33-C2, and 3 of type 33-C3. The time from injury to operation was 3-13 days (mean, 6.5 days). Results All operation incisions healed primarily. Eighteen patients were followed up 12-24 months (mean, 16 months). All fractures healed, and the healing time was 8-24 weeks (mean, 16.6 weeks). The articular surface was smooth and the thigh length was recovered. No screw loosening, plate breakage, valgus or varus of the knee, stiff of the knee or non-unions occurred during follow-up. There was no significant difference in visual analogue scale (VAS) score between at 6 and 12 months after operation (P>0.05), and the difference was significant bewteen the other time points (P<0.05). There were significant differences in the range of motion of knee between 1 month and 3, 6, 12 months (P<0.05); there was no significant difference between 3, 6, and 12 months (P>0.05). There were significant differences in the Neer scores between 1, 3, 6, and 12 months after operation (P<0.05). According to Neer score criteria, the results were excellent in 12 cases and good in 6 cases at 12 months after operation. Conclusion Flexible internal fixation with locking plate for distal femoral fractures can get good functional recovery.
Objective To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures. Methods A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups (P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation. Results Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant (P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group (P<0.05), the incision was significantly longer (P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups (P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups (P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups (P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups (P<0.05). There was no significant difference between the two plate groups (P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups (P>0.05). Conclusion For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Objective To investigate the effectiveness on the re-fracture of the femur with occult infection by using non-contact locking plate which was placed under the deep fascia. Methods Clinical data of 12 cases of occult infective re-fracture after femoral fracture operation were retrospectively analysed between January 2010 and December 2014. There were 8 males and 4 females with an age of 28-69 years (mean, 42.8 years). Femur re-fractured in 5 cases after 3 days to 4 weeks (mean, 10.6 days) of removal of internal fixation, including 4 cases of plate fixation and 1 case of intramedullary nail fixation; femur in 7 cases re-fractured because of breakage of internal fixator after 7-16 months (mean, 9.3 months) of internal fixation, including 5 cases of plate fixation and 2 cases of intramedullary nail fixation. The tissues near the fracture were collected for bacteria culturing and pathological examining. All the patients were treated by debriding the site of the fracture, bridging with the non-contact locking plate, and transplanting with granulated cancellous bone autograft. Intravenous infusion of antibiotics were used for 2-3 weeks after operation and oral administration for 4 weeks. The X-ray films were taken regularly and the function of the knees were evaluated by the Hospital for Special Surgery (HSS) score system. Results The results of bacteria culturing were positive in 8 patients and negative in 4 patients, and the pathological results of all the patients were confirmed to be chronic bone infection. All the fractures healed with no signs of exudation and ulceration of the incisions. The 12 patients were followed up 18-36 months (mean, 29.6 months). The fracture healed well and no re-fracture occurred. The fracture healing time was 14-22 weeks (mean, 18 weeks). At last follow-up, the function of the knee joint was excellent in 9 cases and good in 3 cases according to HSS score system. Conclusion The treatment of re-fractures after femur fracture operation needs to determine whether there is an occult infection, and non-contact locking plate placed under the deep fascia is an effective way for the re-fracture.
ObjectiveTo investigate the effectiveness of pronator quadratus muscle sparing in volar plate fixation for unstable distal radius fracture in adults.MethodsThe clinical data of 62 cases of unstable distal radius fractures between January 2017 and December 2018 were retrospectively analyzed. According to the different methods of intraoperative exposure, the patients were divided into the observe group (28 cases with the pronator quadratus muscle sparing surgery) and the control group (32 cases with cutting the pronator quadratus muscle in operation and repairing it after volar plate fixation). There was no significant difference in general data such as gender, age, handedness, cause of injury, fracture classification, time from injury to operation, visual analogue scale (VAS) score, and range of motion (ROM) of wrist (flexion, extension, pronation, and supination) before operation between the two groups (P>0.05). The operation time, intraoperative blood loss, postoperative hospital stay, fracture healing time, and postoperative complications were recorded and compared between the two groups. VAS score and ROM of wrist of two groups before operation and at 3 days and 3 months after operation were calculated and compared. The wrist function was evaluated according to the Krimmer evaluation criteria at 6 months after operation.ResultsThere was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05). The postoperative hospital stay and fracture healing time of the observe group were significantly shorter than those of the control group (P<0.05). Patients in both groups were followed up 6-30 months, with an average of 13 months. The VAS score and ROM of wrist of the observe group at 3 days after operation were superior to the control group (P<0.05), but there was no significant difference between the two groups at 3 months after operation (P>0.05). At 6 months after operation, according to Krimmer evaluation criteria, the wrist function of the observe group was excellent in 21 cases and good in 7 cases, with an excellent and good rate of 100%; and the wrist function of the control group was excellent in 22 cases, good in 11 cases, and fair in 1 case, with an excellent and good rate of 97.1%. There was no significant difference in wrist function between the two groups (χ2=1.344, P=0.511). One case of poor incision healing occurred in the observe group, and 7 cases of poor incision healing and 5 cases of tendon pain occurred in the control group after operation. The incidence of postoperative complications was less in the observe group (3.6%) than in the control group (35.3%) (χ2=9.325, P=0.002).ConclusionIt is feasible of the pronator quadratus muscle sparing in the volar plate fixation for unstable distal radius fracture in adults. It is beneficial to recover wrist function early after operation, reduce postoperative complications, shorten the length of hospitalization, protect the soft tissue of fracture site, and promote fracture healing.
Objective To investigate the effect of the sequence of intermediate instrumentation with long screws and distraction-reduction on mild to moderate thoracolumbar fractures treated by posterior open and short-segmental fixation. MethodsThe clinical data of 68 patients with mild to moderate thoracolumbar burst fractures who met the selection criteria between January 2016 and June 2019 were retrospectively analyzed. The patients were divided into group ISDRF (intermediate screws then distraction-reduction fixation, 32 cases) and group DRISF (distraction-reduction then intermediate screws fixation, 36 cases) according to the different operation methods. There was no significant difference between the two groups in age, gender, body mass index, fracture segment, cause of injury, and preoperative load-sharing classification score, thoracolumbar injury classification and severity score, vertebral canal occupational rate, back pain visual analogue scale (VAS) score, anterior height of fractured vertebra, and Cobb angle (P>0.05). The operation time, intraoperative blood loss, complications, and fracture healing time were recorded and compared between the two groups. The vertebral canal occupational rate, anterior height of fractured vertebra, kyphosis Cobb angle, and back pain VAS score before and after operation were used to evaluate the effectiveness. Results There was no significant difference in intraoperative blood loss and operation time between the two groups (P>0.05). No vascular or spinal nerve injury and deep infections or skin infections occurred in both groups. At 1 week after operation, the vertebral canal occupational rate in the two groups was significantly improved when compared with that before operation (P<0.05), no significant difference was found in the difference of vertebral canal occupational rate before and after operation and improvement between the two groups (P>0.05). The patients in both groups were followed up 18-24 months, with an average of 22.3 months. All vertebral fractures reached bone union at 6 months postoperatively. At last follow-up, there was no internal fixation failures such as broken screws, broken rods or loose screws, but there were 2 cases of mild back pain in the ISDRF group. The intra-group comparison showed that the back pain VAS score, the anterior height of fractured vertebra, and the Cobb angle of the two groups were significantly improved at each time point postoperatively (P<0.05); the VAS scores at 12 months postoperatively and last follow-up were also improved when compared with that at 1 week postoperatively (P<0.05). At last follow-up, the anterior height of fractured vertebra in the ISDRF group was significantly lost when compared with that at 1 week and 12 months postoperatively (P<0.05), the Cobb angle had a significant loss when compared with that at 1 week postoperatively (P<0.05); the anterior height of fractured vertebra and Cobb angle in DRISF group were not significantly lost when compared with that at 1 week and 12 months postoperatively (P>0.05). The comparison between groups showed that there was no significant difference in the remission rate of VAS score between the two groups at 1 week postoperatively (P>0.05), the recovery value of the anterior height of fractured vertebra in ISDRF group was significantly higher than that in DRISF group (P<0.05), the loss rate at last follow-up was also significantly higher (P<0.05); the correction rate of Cobb angle in ISDRF group was significantly higher than that in DRISF group at 1 week postoperatively (P<0.05), but there was no significant difference in the loss rate of Cobb angle between the two groups at last follow-up (P>0.05). ConclusionIn the treatment of mild to moderate thoracolumbar burst fractures with posterior short-segment fixation, the instrumentation of long screws in the injured vertebrae does not affect the reduction of the fracture fragments in the spinal canal. DRISF can better maintain the restored anterior height of the fractured vertebra and reduce the loss of kyphosis Cobb angle during the follow-up, indicating a better long-term effectiveness.
Objective To investigate the effectiveness of proximal humerus internal locking system (PHILOS) plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture. MethodsThe clinical data of 48 patients with proximal humeral fractures admitted between January 2016 and December 2020 were retrospectively analyzed, including 18 males and 30 females. The age ranged from 28 to 69 years (mean, 56.3 years). The causes of injury included falling in 39 cases and traffic accident in 9 cases. The time from injury to operation was 2-5 days (mean, 2.8 days). All of them were Neer type Ⅳ proximal humerus fractures, including 11 patients with dislocation. All patients underwent internal fixation with a PHILOS plate after anatomical reduction of the greater nodule, and the rotator cuff was sutured to the plate to reinforce fixation. The operation time was recorded, the wound healing, fracture healing, and complications were observed. The visual analogue scale (VAS) score, Constant-Murley shoulder score, University of California Los Angeles (UCLA) score, and American Shoulder and Elbow Surgeons (ASES) score were used to evaluate shoulder function before operation, at 3 months after operation, and at last follow-up. Results The operation time ranged from 65 to 90 minutes (mean, 76.9 minutes). All incisions healed by first intention. All patients were followed up 9-16 months (mean, 12 months). Fracture reduction was good and all fractures healed, the healing time was 2-6 months (mean, 4.6 months). There was no complication such as subacromial impingement, fracture redisplacement, and screw removal during follow-up. One patient had humeral head necrosis, but the basic function of the shoulder joint was acceptable, the symptoms were mild, and no treatment was performed. At 3 months after operation, the upper limb function of the patients basically recovered. The VAS score, Constant-Murley score, UCLA score, and ASES score significantly improved at 3 months after operation and at last follow-up when compared with preoperative, and further improved at last follow-up than at 3 months after operation (P<0.05). ConclusionPHILOS plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture has the advantages of promoting early postoperative rehabilitation exercise, improving postoperative function of shoulder joint, and reducing complications.