west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "limb reconstruction" 2 results
  • Application of Orthofix unilateral external fixator in the treatment of musculoskeletal tumors

    Objective To investigate the surgical characteristics and preliminary effectiveness of Orthofix unilateral external fixator in the treatment of musculoskeletal tumors. Methods Twenty-two patients received Orthofix unilateral external fixator treatment for bone defect after tumor excision or complications after limb salvage surgery between June 2011 and March 2016. There were 11 males and 11 females with a median age of 23.5 years (range, 4-57 years). The bone defect or limb length discrepancy after tumor resection was at proximal femur in 6 cases, distal femur in 8 cases, diaphysis of femur in 3 cases, proximal tibia in 2 cases, and diaphysis of tibia in 3 cases. The external fixation was used for temporary fixation after reconstruction of bone defect in 10 cases [the length of bone defect was 6-19 cm (mean, 12.3 cm); using vascularized fibular graft in 2 cases, allograft bone and free fibular graft in 2 cases, allograft bone and autogenous bone graft in 5 cases, allograft bone reconstruction in 1 case]; bone distraction lengthening for limb length discrepancy in 5 cases [the length of shortening was 6.5-8.5 cm (mean, 7.5 cm)]; temporary fixation after open biopsy in 3 cases; bone transportation over locking plate in 1 case (the length of bone defect was 7.5 cm); fixation for preoperatively pathology fracture in 1 case; and joint distraction for dislocation after tumor ablation in 2 cases. Results All the patients were followed up 12-72 months (mean, 36 months). In 10 patients with bone defect reconstruction, the wearing external fixator time was 3-8 months (mean, 4.8 months); all got bone union with the healing time of 3-16 months (mean, 6.4 months); the Musculoskeletal Tumor Society 93 (MSTS 93) score was 73.3-93.3 (mean, 87.2); and no complication occurred during wearing external fixator. In 5 patients with bone distraction lengthening for limb length discrepancy, the wearing external fixator time was 7-15 months; 2 patients had axial deviation during distraction and2 had greenstick fracture after apparatus removal; pin site infection was observed in 2 cases with grade 1 and 1 case with grade 2 according to Checketts-Otterburn classification system; the MSTS 93 score was 80.0-96.7 (mean, 89.2). The remaining patients had no complications, the knee and ankle joint movement was normal. Conclusion Orthofix unilateral external fixator can be used in fixation for complex bone defect after tumor resection and to correct limb length discrepancy after limb salvage surgery.

    Release date:2017-10-10 03:58 Export PDF Favorites Scan
  • Clinical application of iliac myocutaneous flap pedicled with deep circumflex iliac artery in repair of complex defect of lower limb with cavity

    ObjectiveTo explore the effectiveness of iliac myocutaneous flap pedicled with deep circumflex iliac artery (DCIA) on the repair of lower limb composite defect wounds with cavity. MethodsA retrospective analysis of 7 patients with lower limb composite defect wounds treated between March 2017 and September 2020 was conducted, including 4 males and 3 females, aged 24-58 years, with a median age of 37 years. The causes of injury were machine twisting injury in 2 cases, fall from height injury in 2 cases, and traffic accident injury in 3 cases. According to Gustilo-Anderson classification, there were 1 case of type Ⅲa, 4 cases of type Ⅲb, and 2 cases of type Ⅲc (combined with anterior tibial artery rupture); according to AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 2 cases of type 42-C3, 2 cases of type 43-A2, and 3 cases of type 43-B1. The time from injury to admission ranged from 2 to 10 hours, with an average of 6 hours. Tibial bone defect and surrounding soft tissue defect with deep cavity were left after primary emergency debridement. In the second stage, according to the characteristics of the wound, the three-dimensional repair of the composite defect was designed with DCIA embedded iliac myocutaneous flap. The size of the iliac flap was 2.0 cm×2.0 cm×2.0 cm to 7.0 cm×3.0 cm×2.5 cm, and the size of the flap was 12.0 cm×8.0 cm to 21.0 cm×13.0 cm. The internal oblique muscle flap was harvested in size of 3.0 cm×2.0 cm×2.0 cm to 5.5 cm×4.0 cm×4.0 cm. The donor site was primarily closed. ResultsAll the flaps survived after operation, except for 1 case of partial necrosis of the flap edge, which healed after secondary skin grafting, and the donor and recipient wounds healed by first intention. All patients were followed up 16-24 months, with an average of 18 months. The broken end of the bone defect healed well, and the healing time was 8-10 months, with an average of 7.3 months. At last follow-up, the shape of the flap was satisfactory, the texture was soft, and there was no abnormal hair growth, pigmentation, and so on. Only linear scar was left in the donor site, and no complication such as abdominal hernia occurred. According to Paley fracture healing scoring system, bone healing was rated as excellent in 5 cases and good in 2 cases. The limb function was satisfactory, and full weight bearing was achieved at 12-16 months after operation. According to the lower extremity functional scale (LEFS), 6 cases were excellent and 1 case was good. Conclusion The iliac myocutaneous flap pedicled with DCIA is flexible in design and highly free in tissue composition, which can repair the composite defect wound of lower limbs with deep cavity in a three-dimensional way, and repair the limb shape and reconstruct weight-bearing function to the greatest extent.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content