west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "monitoring" 102 results
  • Constitution of a Real-time Monitoring System of Cerebral Hemorrhage with Magnetic Induction

    The real-time monitoring of cerebral hemorrhage can reduce its disability and fatality rates greatly. On the basis of magnetic induction phase shift, we in this study used filter and amplifier hardware module, NI-PXI data-acquisition system and LabVIEW software to set up an experiment system. We used Band-pass sample method and correlation phase demodulation algorithm in the system. In order to test and evaluate the performance of the system, we carried out saline simulation experiments of brain hemorrhage. We also carried out rabbit cerebral hemorrhage experiments. The results of both saline simulation and animal experiments suggested that our monitoring system had a high phase detection precision, and it needed only about 0.030 4s to finish a single phase shift measurement, and the change of phase shift was directly proportional to the volume of saline or blood. The experimental results were consistent with theory. As a result, this system has the ability of real-time monitoring the progression of cerebral hemorrhage precisely, with many distinguished features, such as low cost, high phase detection precision, high sensitivity of response so that it has showed a good application prospect.

    Release date: Export PDF Favorites Scan
  • Effects of health education based on process communication mode on the success rate and active cooperation rate of video EEG monitoring in elderly patients

    ObjectiveVideo electroencephalography (VEEG) monitoring for health education of elderly patients based on a process-based communication model, and explore the impact of this model on the success rate, negative emotions, nursing satisfaction, and active cooperation rate of such patients.MethodsFrom September 2017 to September 2019, 118 patients with suspected epilepsy, encephalitis and other diseases who required VEEG monitoring in Suining Central Hospital were selected for this study (patients aged 61 to 73 years; 54 males and 64 females). Patients were divided into 2 groups using a random number table method, 59 patients in each group.A group received routine nursing, and B group received health education based on the process communication model. The monitoring success rate, negative emotion, active cooperation rate, and nursing satisfaction were compared between the two groups.ResultsThe total effective rate in the B group was 86.44%, which was significantly higher than 76.27% in the A group (P<0.05). After nursing intervention, the scores of anxiety and depression in the two groups were significantly decreased, but the decline was greater in the B group (P<0.05). The active cooperation rate and nursing satisfaction of the B group were significantly higher than those of the A group (P<0.05).ConclusionCompared with conventional nursing, health education based on process communication mode can significantly improve the success rate of VEEG monitoring in elderly patients, alleviate the negative emotions of patients, improve the active cooperation rate and nursing satisfaction.

    Release date:2020-05-19 01:07 Export PDF Favorites Scan
  • Evidence-Based Safety Reassessment of Post Marketed Drug - Importance of Recall of Refecoxib

    This article aims to review the recall of refecoxib which increases the incidence of cardiovascular and cerebrovascular diseases and to find the methods to solve problems in post marked monitoring of drug safety.

    Release date:2016-09-07 02:25 Export PDF Favorites Scan
  • Application progress of venous pressure monitoring in arteriovenous fistula

    Venous pressure monitoring is an important indicator for the arteriovenous fistula evaluation. Direct static venous pressure monitoring is recognized as the most accurate way of venous pressure monitoring, which is widely used in the functional monitoring, functional evaluation of arteriovenous fistula, the diagnosis of complications and the evaluation of surgical efficacy. Venous pressure monitoring has obvious advantages and disadvantages, so it is necessary to improve relevant knowledge to correctly guide clinical diagnosis and treatment. In this paper, the study of static venous pressure monitoring of arteriovenous fistula was summarized, in order to improve the understanding of the significance and clinical application of static venous pressure monitoring of arteriovenous fistula.

    Release date:2022-08-24 01:25 Export PDF Favorites Scan
  • A summary of research progress on intelligent information processing methods for pregnant women's remote monitoring

    The monitoring of pregnant women is very important. It plays an important role in reducing fetal mortality, ensuring the safety of perinatal mother and fetus, preventing premature delivery and pregnancy accidents. At present, regular examination is the mainstream method for pregnant women's monitoring, but the means of examination out of hospital is scarce, and the equipment of hospital monitoring is expensive and the operation is complex. Using intelligent information technology (such as machine learning algorithm) can analyze the physiological signals of pregnant women, so as to realize the early detection and accident warning for mother and fetus, and achieve the purpose of high-quality monitoring out of hospital. However, at present, there are not enough public research reports related to the intelligent processing methods of out-of-hospital monitoring for pregnant women, so this paper takes the out-of-hospital monitoring for pregnant women as the research background, summarizes the public research reports of intelligent processing methods, analyzes the advantages and disadvantages of the existing research methods, points out the possible problems, and expounds the future development trend, which could provide reference for future related researches.

    Release date:2020-12-14 05:08 Export PDF Favorites Scan
  • Technical Research of Non-contact Electrocardiogram Based on Capacitive Coupling

    Based on the capacitance coupling principle, we studied a capacitive way of non-contact electrocardiogram (ECG) monitoring, making it possible to obtain ECG on the condition that a patient is habilimented. Conductive fabric with a good electrical conductivity was used as electrodes. The electrodes fixed on a bed sheet is presented in this paper. A capacitance comes into being as long as the body gets close to the surface of electrode, sandwiching the cotton cushion, which acts as dielectric. The surface potential generated by heart is coupled to electrodes through the capacitance. After being processed, the signal is suitable for monitoring. The test results show that 93.5% of R wave could be detected for 9 volunteers and ECG with good signal quality could be acquired for 2 burnt patients. Non-contact ECG is harmless to skin, and it has advantages for those patients to whom stickup electrodes are not suitable. On the other hand, it is convenient to use and good for permanent monitoring.

    Release date: Export PDF Favorites Scan
  • Research progress on minimally invasive and non-invasive blood glucose detection methods

    Blood glucose monitoring has become the weakest point in the overall management of diabetes in China. Long-term monitoring of blood glucose levels in diabetic patients has become an important means of controlling the development of diabetes and its complications, so that technological innovations in blood glucose testing methods have far-reaching implications for accurate blood glucose testing. This article discusses the basic principles of minimally invasive and non-invasive blood glucose testing assays, including urine glucose assays, tear assays, methods of extravasation of tissue fluid, and optical detection methods, etc., focuses on the advantages of minimally invasive and non-invasive blood glucose testing methods and the latest relevant results, and summarizes the current problems of various testing methods and prospects for future development trends.

    Release date:2023-06-25 02:49 Export PDF Favorites Scan
  • Design and implementation of real-time continuous glucose monitoring instrument

    Real-time continuous glucose monitoring can help diabetics to control blood sugar levels within the normal range. However, in the process of practical monitoring, the output of real-time continuous glucose monitoring system is susceptible to glucose sensor and environment noise, which will influence the measurement accuracy of the system. Aiming at this problem, a dual-calibration algorithm for the moving-window double-layer filtering algorithm combined with real-time self-compensation calibration algorithm is proposed in this paper, which can realize the signal drift compensation for current data. And a real-time continuous glucose monitoring instrument based on this study was designed. This real-time continuous glucose monitoring instrument consisted of an adjustable excitation voltage module, a current-voltage converter module, a microprocessor and a wireless transceiver module. For portability, the size of the device was only 40 mm × 30 mm × 5 mm and its weight was only 30 g. In addition, a communication command code algorithm was designed to ensure the security and integrity of data transmission in this study. Results of experiments in vitro showed that current detection of the device worked effectively. A 5-hour monitoring of blood glucose level in vivo showed that the device could continuously monitor blood glucose in real time. The relative error of monitoring results of the designed device ranged from 2.22% to 7.17% when comparing to a portable blood meter.

    Release date:2017-12-21 05:21 Export PDF Favorites Scan
  • Quality management of long-term video-EEG monitoring process

    ObjectiveTo summarize the method of quality management in long term video electroencephalogram (VEEG) monitoring process.MethodsTo summarize the VEEG monitoring process in 4 935 patients, the following methods were adopted: adequate preparation before examination, selection of suitable electrode wearing methods, regular inspection of the quality of the lead wire, inspection and observation of whether the electrodes have fallen off, process inspection, behavioral intervention guidance, timely manage the artifacts, pay more attention to the inducted experimental, timely identification of paroxysmal events, standardize the procedures for the management of seizures, standardize the processing of electrode cleaning and disinfection, continuously improve the quality.ResultsFour hundred and tworoy are paroxysmal events of various types occurred during the monitoring period. All of them were handled in time and the patients were all safe. Among these events, 4 children ended the examination in ahead of the normal procedure due to fever, crying or other reasons. two patients were transferred to intensive care unit due to changes in patients ’conditions such as hypopnea and decreased oxygen saturation of artery blood of finger. The remaining 4 829 patients completed VEEG detection for 8 ~ 24 h. and got good quality images.ConclusionsQuality management is a guarantee of qualified, high quality, low artifact EEG reports.

    Release date:2019-03-21 11:04 Export PDF Favorites Scan
  • Clinical Application of Recurrent Laryngeal Nerve Protection and Monitoring During Thyroidectomy

    Objective To investigate the clinical significance of visual identification and intraoperative neuromonitoring of recurrent laryngeal nerve (RLN) during thyroidectomy. Methods Totally 1 664 patients underwent thyroidectomy with RLN protection from January 2009 to December 2009 were included in this study, in which 1 447 cases were protected by visual identification only, and 217 complex thyroidectomy cases were protected by visual identification and intraoperative monitoring. Results By the “multisites, three steps” RLN exposure method, 1 417 cases (85.16%) were successfully recognized and the recognition time was (3.57±1.26) min. The recognition time in the rest 30 complex cases (2.07%) without intraoperative neuromonitoring was (17.02±5.48) min. By this method, the temporary RLN injury occurred in 23 cases (1.54%) and 15 cases (65.22%) recovered within 2 weeks. In patients undewent intraoperative neuromonitoring, the recognition rate was 100% (217/217) and recognition time was (2.18±0.67) min. The temporary RLN injury occurred in 4 cases (1.84%) and 3 cases (75.00%) recovered within 2 weeks. All temporary RLN injuries recovered within 1 month and no persistent RLN injury occurred. Conclusions Conventional visual identification can reduce the RLN injury, but not meet the needs of the RLN protection during complex thyroidectomy. The combination of visual identification and intraoperative neuromonitoring can further improve the recognition rate and shorten the recovery time of vocal cord dyskinesia.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
11 pages Previous 1 2 3 ... 11 Next

Format

Content