west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "percutaneous screw" 3 results
  • The safety of TiRobot-guided percutaneous transpedicular screw implantation

    ObjectiveTo evaluate the safety of TiRobot-guided percutaneous transpedicular screw implantation.MethodsThe medical records of 158 patients with thoracolumbar fractures and lumbar degenerative diseases who underwent percutaneous transpedicular screw implantation were retrospectively analyzed between January 2018 and December 2020. The patients were divided into trial group (TiRobot-guided screw implantation, 86 cases) and control group (fluoroscopy-guided screw implantation, 72 cases). There was no significant difference in gender, age, pathology, lesion segment, and the average number of screw implantation per case (P>0.05). The operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency were compared between the two groups. One day postoperatively, the convergence angle was measured and the penetration of the pedicle cortex was evaluated according to Gertzbein-Robbins classification standard.ResultsThe operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency of the trial group were significantly lesser than those of control group (P<0.05).One day postoperatively, the convergence angle of trial group was (21.10±4.08)°, which was significantly larger than control group (19.17±3.48)° (t=6.810, P=0.000). According to the Gertzbein-Robbins classification standard, 446 pedicle screws were implanted in trial group, trajectories were grade A in 377 screws, grade B in 46 screws, grade C in 23 screws, and the accuracy of screw implantation was 94.8%; 380 pedicle screws were implanted in control group, trajectories were grade A in 283 screws, grade B in 45 screws, grade C in 44 screws, grade D in 6 screws, grade E in 2 screws, and the accuracy of screw implantation was 86.3%. There was significant difference in the accuracy of screw implantation between the two groups (χ2=25.950, P=0.000). ConclusionCompared with traditional percutaneous transpedicular screw implantation, TiRobot-guided percutaneous transpedicular screw implantation can improve the accuracy of screw implantation, reduce radiation exposure, and improve surgical safety, which has a good application prospect.

    Release date:2021-06-30 04:43 Export PDF Favorites Scan
  • Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures

    Objective To investigate the accuracy and safety of percutaneous screw fixation for pelvic and acetabular fractures with remote navigation of orthopedic robot based on 5G technology. Methods Between January 2021 and December 2021, 15 patients with pelvic and/or acetabular fractures were treated with percutaneous screws fixation which were placed by remote navigation of orthopedic robot based on 5G technology. There were 8 males and 7 females. The age ranged from 20 to 98 years, with an average of 52.1 years. The causes of trauma included traffic accident injury in 6 cases, falling from height injury in 6 cases, fall injury in 2 cases, and heavy object smashing injury in 1 case. The time from injury to operation ranged from 3 to 32 days, with an average of 10.9 days. There were 8 cases of simple pelvic fractures, 2 simple acetabular fractures, and 5 both pelvic and acetabular fractures. There were 7 cases of pelvic fractures of Tile type B2, 2 type B3, 1 type C1, and 3 type C2; 4 cases of unilateral anterior column fracture of the acetabulum, 2 bilateral anterior column fractures, and 1 anterior wall fracture. CT images within 5 days after operation were collected for screw position assessment. The screw planning time and guidewire placement time were recorded, as well as the presence of intraoperative adverse events and complications within 5 days after operation. Results All patients achieved satisfactory surgical results. A total of 36 percutaneous screws were inserted (20 sacroiliac screws, 6 LC Ⅱ screws, 9 anterior column screws, and 1 acetabular apical screw). In terms of screw position evaluation, 32 screws (88.89%) were excellent and 4 screws (11.11%) were good; there was no screw penetrating cortical bone. The screw planning time ranged from 4 to 15 minutes, with an average of 8.7 minutes. The guidewire placement time ranged from 3 to 10 minutes, with an average of 6.8 minutes. The communication delayed in 2 cases, but the operation progress was not affected, and no serious intraoperative adverse events occurred. No delayed vascular or nerve injury, infection, or other complications occurred within 5 days after operation. No cases need surgical revision. ConclusionThe fixation of pelvic and acetabular fractures by percutaneous screw with remote navigation of orthopedic robot based on 5G technology is accurate, safe, and reliable.

    Release date: Export PDF Favorites Scan
  • Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures

    Objective To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures. Methods A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex. Results No significant difference was observed in operation time between the two groups (P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex (P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups (P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group (P<0.05). ConclusionCompared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content