west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "posterolateral column" 2 results
  • Application of modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column

    ObjectiveTo explore effectiveness of reduction and internal fixation via modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column.MethodsBetween January 2016 and September 2018, 19 patients diagnosed as tibial plateau fractures involving posterolateral column were treated with reduction and internal fixation via modified anterolateral supra-fibular-head approach. There were 11 males and 8 females with an average age of 43.2 years (range, 28-65 years). The causes of tibial fracture were traffic accident (12 patients), falling injury (5 patients), and falling from height (2 patients). According to the Schatzker typing, the tibial fractures were rated as type Ⅱ in 9 cases, type Ⅲ in 4 cases, type Ⅴ in 4 cases, and type Ⅵ in 2 cases. The time from injury to operation was 5-13 days (mean, 8.5 days). There were 2 patients with osteoporosis. The operation time, intraoperative blood loss, and postoperative complications were recorded. The knee X-ray film was reviewed regularly to observe the fracture healing. At last follow-up, the fracture reductions were evaluated by Rasmussen radiological score. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score system.ResultsThe average operation time was 95 minutes (range, 65-130 minutes). The average intraoperative blood loss was 220 mL (range, 150-350 mL). All incisions healed by first intention. No complications such as infection or deep venous thrombosis occurred. All patients were followed up 12-20 months (mean, 15.4 months). X-ray films showed that the fractures healed with the healing time of 12-20 weeks (mean, 14.5 weeks). No complications such as loosening or breakage of internal fixation occurred. At last follow-up, according to the Rasmussen radiological score, the fracture reductions were evaluated as excellent in 13 cases, good in 4 cases, fair in 1 case, and poor in 1 case. HSS scores of knee joint function were excellent in 14 cases, good in 3 cases, fair in 1 case, and poor in 1 case. The knee joint range of motion was 90°-135°, with an average of 113.4°.ConclusionApplication of modified anterolateral supra-fibular-head approach in reduction and internal fixation for tibial plateau fractures involving posterolateral column has the advantages of full exposure, less trauma, safety, and reliable reduction and fixation.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Application of a new universal locking anatomical plate in treatment of tibial plateau posterolateral column fractures

    Objective To investigate the effectiveness of a new tibial plateau posterolateral column universal locking anatomical plate (hereinafter referred to as “new universal locking anatomical plate”) in the treatment of tibial plateau posterolateral column fractures. Methods Between October 2020 and December 2021, 14 patients with tibial plateau posterolateral column fracture were treated with a new universal locking anatomical plate. There were 7 males and 7 females with an average age of 59 years ranging from 29 to 75 years. There were 5 cases on the left side and 9 cases on the right side. The causes of injury included falling from height in 5 cases, traffic accident in 7 cases, and other injuries in 2 cases. The time from injury to operation ranged from 3 to 10 days, with an average of 6 days. According to Schatzker classification, there were 4 cases of type Ⅱ, 8 cases of type Ⅴ, and 2 cases of type Ⅵ. All fractures involved the posterolateral tibial plateau. Three column classification: two columns (anterolateral column+posterior column) in 4 cases, three columns in 10 cases. The operation time, intraoperative blood loss, fracture healing, and complications were recorded. The reduction of tibial plateau fracture was evaluated by Rasmussen radiographic score, and the recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score. Results All 14 cases completed the operation successfully. The operation time was 95-180 minutes, with an average of 154 minutes, and the intraoperative blood loss was 100-480 mL, with an average of 260 mL. All patients were followed up 6-19 months, with an average of 12.5 months. All fractures healed, and the healing time was 15-24 weeks, with an average of 18.7 weeks. During the follow-up, there was 1 case of common peroneal nerve palsy and 1 case of traumatic osteoarthritis. There was no other complication such as vascular injury, incision infection, deep venous thrombosis of lower limbs, heterotopic ossification, bone nonunion, and failure of internal fixation. The reduction of tibial plateau fractures was good immediately after operation, and the Rasmussen radiological score was 10-18, with an average of 15.7; 3 cases were excellent, 10 cases were good, and 1 case was fair, with an excellent and good rate of 92.9%. The scores and grades of HSS at 3 months after operation and at last follow-up significantly improved when compared with those before operation (P<0.05). There was no significant difference between 3 months after operation and last follow-up (P>0.05).Conclusion For the fractures involving the posterolateral column of the tibial plateau, the new universal locking anatomical plate can provide strong fixation, satisfactory postoperative fracture reduction, and good recovery of knee function.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content