Rapid development is undergoing in the field of rehabilitation robots, and more countries (regions) are participating in international cooperation and becoming academic contributors. Here in this study, the bibliometric method is used to determine the dynamics and developments of international cooperation in China. The publication data are indexed in Web of Science with search term of rehabilitation robot from 2000 to 2019. Compared with other countries (regions), publication with international co-authors and institutes participating in international cooperation are studied by assessment of indicators such as the cooperation degree, cooperation frequency, and the frequency of citations. The results show that in the past two decades, international scientific cooperation has shown a positive tendency in China, and participating in international collaboration could improve China’s impact on the global rehabilitation robot. The United States, England and Japan are the top three countries in number of cooperation with China. Our findings provide valuable information for researchers to better understand China’s international scientific collaboration in rehabilitation robot.
ObjectiveTo investigate the changes in pulmonary function after video-assisted thoracic surgery (VATS) and robot-assisted thoracic surgery (RATS) segmentectomy.MethodsA total of 59 patients (30 males and 29 females) who underwent segmentectomy in the Affiliated Hospital of Qingdao University from July to October 2017 were included. There were 33 patients (18 males and 15 females) in the VATS group and 26 patients (12 males and 14 females) in the RATS group. Lung function tests were performed before surgery, 1 month, 6 months, and 12 months after surgery. Intra- and inter-group comparisons of lung function retention values were performed between the two groups of patients to analyze differences in lung function retention after VATS and RATS segmentectomy.ResultsThe forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) in the VATS group and the RATS group were significantly lower than those before surgery (P<0.05), and they increased significantly within 6 months after surgery (P<0.05). The recovery was not obvious after 6 months (P>0.05), and they were still lower than those before surgery. In addition, the retentions of FEV1 and FVC in the VATS group and the RATS group were similar in 1 month, 6 months, and 12 months after operation with no statistical difference(P>0.05). ConclusionPulmonary function decreases significantly in 1 month after minimally invasive segmentectomy, and the recovery is obvious in 6 months after the operation, then the pulmonary function recovery gradually stabilizes 12 months after surgery. FEV1 of the patients in the two groups recovers to 93% and 94%, respectively. There is no statistical difference in pulmonary function retention after VATS and RATS segmentectomy.
ObjectiveTo compare the perioperative outcomes between robot-assisted complex segmentectomy and simple segmentectomy for stage ⅠA non-small cell lung cancer (NSCLC). MethodsThe clinical data of 285 patients with NSCLC undergoing robot-assisted thoracic surgery (RATS) in our hospital from January 2015 to August 2021 were retrospectively analyzed. There were 105 males and 180 females aged 23-83 years. The patients were divided into a complex segmentectomy group (n=170) and a simple segmentectomy group (n=115) according to tumor location and surgical method. The clinical pathological baseline characteristics and perioperative outcomes between the two groups were compared, including operative time, blood loss volume, dissected lymph nodes, conversion rate, postoperative duration of drainage, postoperative hospital stay, the incidence of persistent air leakage and postoperative 30 d mortality. ResultsThere was no statistical difference in baseline data between the two groups (P>0.05). No postoperative 30 d death was observed. One patient in the complex segmentectomy group was transferred to thoracotomy. No statistical difference was observed between the two groups in the operative time (97.36±38.16 min vs. 94.65±31.67 min, P=0.515), postoperative duration of drainage (3.69±1.85 d vs. 3.60±1.90 d, P=0.679), postoperative hospital stay (4.07±1.85 d vs. 4.05±1.97 d, P=0.957), dissected lymph nodes (5.15±3.53 vs. 5.13±2.93, P=0.952), incidence of blood loss volume<100 mL (98.2% vs. 99.1%, P=0.650), and incidence of postoperative persistent air leakage (6.5% vs. 5.2%, P=0.661). ConclusionThe safety and effectiveness of robot-assisted complex segmentectomy and simple segmentectomy are satisfactory in the treatment of stage ⅠA NSCLC. The perioperative results of RATS complex segmentectomy and simple segmentectomy are similar.
Nowadays, the development of the medical instrument industry makes rapid changes in clinical practice. Hybridization of latest technology is playing an increasingly important role in the diagnosis and treatment of disease. Especially, the trend of the integration of three-channel hybrid technology in diagnosis and treatment of early lung cancer has become increasingly obvious. This paper will focus on the technical advance of the three-channel multi- mirror robot and its application in the diagnosis and treatment of early lung cancer.
In order to accurately implant the brain electrodes of carp robot for positioning and navigation, the three-dimensional model of brain structure and brain electrodes is to be proposed in the study. In this study, the tungsten electrodes were implanted into the cerebellum of a carp with the aid of brain stereotaxic instrument. The brain motor areas were found and their three-dimensional coordinate values were obtained by the aquatic electricity stimulation experiments and the underwater control experiments. The carp brain and the brain electrodes were imaged by 3.0 T magnetic resonance imaging instrument, and the three-dimensional reconstruction of carp brain and brain electrodes was carried out by the 3D-DOCTOR software and the Mimics software. The results showed that the brain motor areas and their coordinate values were accurate. The relative spatial position relationships between brain electrodes and brain tissue, brain tissue and skull surface could be observed by the three-dimensional reconstruction map of brain tissue and brain electrodes which reconstructed the three-dimensional structure of brain. The anatomical position of the three-dimensional reconstructed brain tissue in magnetic resonance image and the relationship between brain tissue and skull surface could be observed through the three-dimensional reconstruction comprehensive display map of brain tissue. The three-dimensional reconstruction model in this study can provide a navigation tool for brain electrodes implantation.
Objective To compare the short-term effectiveness of “SkyWalker” robot-assisted total knee arthroplasty (TKA) and traditional TKA. Methods A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent “SkyWalker” robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups (P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed. ResultsThe operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups (P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference (P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones (P<0.05). There was no significant difference between the two groups (P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones (P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators (P>0.05). Conclusion The “SkyWalker” robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.
ObjectiveTo compare the surgical efficacy of Da Vinci robot-assisted minimally invasive esophagectomy (RAMIE) and video-assisted minimally invasive esophagectomy (VAMIE) on esophageal cancer.MethodsOnline databases including PubMed, the Cochrane Library, Medline, EMbase and CNKI from inception to 31, December 2019 were searched by two researchers independently to collect the literature comparing the clinical efficacy of RAMIE and VAMIE on esophageal cancer. Newcastle-Ottawa Scale was used to assess quality of the literature. The meta-analysis was performed by RevMan 5.3.ResultsA total of 14 studies with 1 160 patients were enrolled in the final study, and 12 studies were of high quality. RAMIE did not significantly prolong total operative time (P=0.20). No statistical difference was observed in the thoracic surgical time through the McKeown surgical approach (MD=3.35, 95%CI –3.93 to 10.62, P=0.37) or in surgical blood loss between RAMIE and VAMIE (MD=–9.48, 95%CI –27.91 to 8.95, P=0.31). While the RAMIE could dissect more lymph nodes in total and more lymph nodes along the left recurrent laryngeal recurrent nerve (MD=2.24, 95%CI 1.09 to 3.39, P=0.000 1; MD=0.89, 95%CI 0.13 to 1.65, P=0.02) and had a lower incidence of vocal cord paralysis (RR=0.70, 95%CI 0.53 to 0.92, P=0.009).ConclusionThere is no statistical difference observed between RAMIE and VAMIE in surgical time and blood loss. RAMIE can harvest more lymph nodes than VAMIE, especially left laryngeal nerve lymph nodes. RAMIE shows a better performance in reducing the left laryngeal nerve injury and a lower rate of vocal cord paralysis compared with VAMIE.
Objective To review the research progress related to endoscopic surgery and robotic surgery for breast diseases, aiming to provide references for clinical practice. Methods The recent domestic and international literature on endoscopic surgery and robotic surgery for breast diseases was reviewed, then the challenges in their development, the innovative evolution of endoscopic surgery combined with clinical practice by our team, and its clinical applications were summarized. ResultsTraditional endoscopic surgery, despite its advantages such as minimal invasiveness, good cosmetic outcomes, and high patient’s satisfaction, has been limited in its development due to specific difficulties in establishing the operative field. Our team innovatively proposed the “reverse sequence method” and the Huaxi Hole 1 theory and methods, cleverly altering the surgical procedure sequence, adding small operative orifices to transform single-port operations into multi-port ones, effectively overcoming the challenges restricting the advancement of endoscopic surgery in the field of breast diseases, thereby enabling further proliferation of endoscopic procedures. In terms of breast endoscopic reconstruction surgery, the parachute patch technique has broadened the indications for reconstruction surgery, benefiting patients with a certain degree of breast ptosis; and the postoperative adjustment concept, through early intervention in the post-reconstruction breast shape, has further refined the reconstruction procedure. Robot-assisted surgery derived from endoscopic surgery theory has further enhanced the precision and stability of surgeries, reducing surgical risks; however, excessive time and economic costs are urgent issues that must be addressed. Conclusion Through theoretical innovations, endoscopic surgery has been applied in the excision and reconstruction of breast lesions, while robotic surgery shows promising applications in autologous breast reconstruction, especially in the latissimus dorsi reconstruction field. Nevertheless, the lack of high-level large-sample, multi-center randomized controlled clinical trials to confirm its surgical safety, oncological safety, and postoperative cosmetic outcomes is an important direction for future research.
Objective To compare the effectiveness of spinal robot-assisted pedicle screw placement through different surgical approaches and to guide the clinical selection of appropriate robot-assisted surgical approaches. MethodsThe clinical data of 14 patients with thoracolumbar vertebral diseases who met the selection criteria between January 2023 and August 2023 were retrospectively analyzed, and all of them underwent pedicle screw placement under assistant of the Mazor X spinal surgery robot through different surgical approaches. The patients were divided into posterior median approach (PMA) group (n=6) and intermuscular approach (IMA) group (n=8) according to the surgical approaches, and there was no significant difference in age, gender, body mass index, disease type, and fixed segment between the two groups (P>0.05). The operation time, intraoperative blood loss, screw-related complications, and reoperation rate were recorded and compared between the two groups; the inclination angle of the screw, the distance between the screw and the midline, and the caudal inclination angle of the screw were measured based on X-ray films at immediate after operation. Results There was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05). There was no screw-related complication such as nerve injury in both groups, and no patients underwent secondary surgery. At immediate after operation, the inclination angle of the screw, the distance between the screw and the midline, and the caudal inclination angle of the screw in the IMA group were significantly greater than those in the PMA group (P<0.05). ConclusionThere are differences in the position and inclination angle of screws placed with robot-assisted surgery through different surgical approaches, which may be due to the obstruction of the screw path by soft tissues such as skin and muscles. When using spinal robot-assisted surgery, selecting the appropriate surgical approach for different diseases can make the treatment more reasonable and effective.
To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.