west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "scintigraphy" 2 results
  • Clinical Evaluation of Regional Electric Impedance Pneumograph and Scintigraphy in Patiens with COPD

    摘要:目的:应用区域阻抗法测定慢性阻塞性肺疾病(COPD)患者的肺血流灌注及肺通气分布的变化,与放射性核素肺显像方法比较,探讨肺区域阻抗方法的临床应用价值。 方法: 测定对象为18例中重度COPD患者,均为男性,平均年龄63.8岁,应用肺区域阻抗法及放射性核素法,分别测定肺血流灌注及肺通气的分布。〖HTH〗结果〖HTSS〗: 本研究发现肺区域阻抗法在测定肺血流灌注分布方面,仅在左下肺区域高于核素法测得的数值(Plt;0.05),余肺区测定结果相近,无显著差异。在肺通气的测定方面,阻抗法所得数值与核素法测得的数值有一定的不同,在左上、右上区域高于核素法测得的数值,在左中肺区测得的数值低于核素法测得的数值(Plt;0.05),余肺区测定结果相近,无显著差异。结论: 虽然目前区域阻抗方法暂不能取代放射性核素的测定,但作为一种辅助手段,可简便、快速了解肺内的通气、血流等生理病理改变。Abstract: Objective: To evaluate the clinical capability of regional electric impedance pneumograph and scintigraphy in measurement of pulmonary perfusion and ventilation in patients with COPD. Methods: Thirtytwo patients with different respiratory diseases underwent regional electric impedance pneumograph and scintigraphy, the pulmonary perfusion and ventilation were obtained and recorded. Results:The pulmonary perfusion results got by regional electric impedance pneumograph in the left lower region was lower than the results measured by scintigraphy, there were significant difference (Plt;0.05), and no difference in other pulmonary region. The pulmonary ventilation results got by regional electric impedance pneumograph in the both upper region were higher and in the left middle region were lower than the results measured by scintigraphy, there were significant difference(Plt;0.05), and no difference in other pulmonary region. Conclusion:The result got by regional electric impedance pneumograph could not replace the result got by scintigraphy at present, but this is a quick, simple,and convenient measurement to get parameter of the pulmonary perfusion and ventilation.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Comparative Study and False Negative Cases Analysis of Preoperative Ultrasonography, 99Tcm-Sestamibi Scinti-graphy, and CT in Primary Hyperparathyroidism

    Objective To evaluate the diagnostic significance and to analyze reasons of false negative cases forpreoperative ultrasonography, 99Tcm-sestamibi scintigraphy (MIBI scintigraphy), and CT in primary hyperparathyroidism(PHPT). Methods Clinical data of 69 patients with PHPT, who underwent operation in Affiliated Shengjing Hospital of China Medical University between Jan. 2003 and Aug. 2012 were retrospectively analyzed. Results There were 76 parathyroid lesions in 69 PHPT patients proved by operation and pathology, including 58 cases of parathyroid adenoma with 60 lesions, 7 cases of parathyroid hyperplasia with 11 lesions, and 4 cases of parathyroid carcinoma with 5 lesions. The sensitivity of ultrasonography, CT, and 99Tcm-MIBI scintigraphy were 81.94% (59/72), 61.76% (21/34), and 69.57% (16/23), the accuracy of 3 kinds of tests were 78.67% (59/75), 61.76% (21/34), and 66.67% (16/24), the positive predictive value were 95.16% (59/62), 100% (21/21), and 94.12% (16/17) respectively. There was significant differ-ence only between ultrasonography and CT in sensitivity (P=0.03), no other significant difference was found (P>0.05).Conclusions Ultrasonography is complementary to 99Tcm-MIBI scintigraphy, but CT has little significance in diagnosis of PHPT. Both of ultrasonography and 99Tcm-MIBI scintigraphy should be used before operation routinely to localize parathyroid lesions.

    Release date:2016-09-08 10:35 Export PDF Favorites Scan