west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "statistical process control" 2 results
  • Anomaly Detection of Multivariate Time Series Based on Riemannian Manifolds

    Multivariate time series problems widely exist in production and life in the society. Anomaly detection has provided people with a lot of valuable information in financial, hydrological, meteorological fields, and the research areas of earthquake, video surveillance, medicine and others. In order to quickly and efficiently find exceptions in time sequence so that it can be presented in front of people in an intuitive way, we in this study combined the Riemannian manifold with statistical process control charts, based on sliding window, with a description of the covariance matrix as the time sequence, to achieve the multivariate time series of anomaly detection and its visualization. We made MA analog data flow and abnormal electrocardiogram data from MIT-BIH as experimental objects, and verified the anomaly detection method. The results showed that the method was reasonable and effective.

    Release date: Export PDF Favorites Scan
  • Preliminary study on monitoring patient-specific volumetric modulated arc therapy quality assurance process with statistical process control methodology on the basis of TG-218 report

    Patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) process is an important component of the implementation process of clinical radiotherapy. The tolerance limit and action limit of discrepancies between the calculated dose and the delivered radiation dose are the key parts of the VMAT QA processes as recognized by the AAPM TG-218 report, however, there is no unified standard for these two values among radiotherapy centers. In this study, based on the operational recommendations given in the AAPM TG-218 report, treatment site-specific tolerance limits and action limits of gamma pass rate in VMAT QA processes when using ArcCHECK for dose verification were established by statistical process control (SPC) methodology. The tolerance limit and action limit were calculated based on the first 25 in-control VMAT QA for each site. The individual control charts were drawn to continuously monitor the VMAT QA process with 287 VMAT plans and analyze the causes of VMAT QA out of control. The tolerance limits for brain, head and neck, abdomen and pelvic VMAT QA processes were 94.56%, 94.68%, 94.34%, and 92.97%, respectively, and the action limits were 93.82%, 92.54%, 93.23%, and 90.29%, respectively. Except for pelvic, the tolerance limits for the brain, head and neck, and abdomen were close to the universal tolerance limit of TG-218 (95%), and the action limits for all sites were higher than the universal action limit of TG-218 (90%). The out-of-control VMAT QAs were detected by the individual control chart, including one case of head and neck, two of the abdomen and two of the pelvic site. Four of them were affected by the setup error, and one was affected by the calibration of ArcCHECK. The results show that the SPC methodology can effectively monitor the IMRT/VMAT QA processes. Setting treatment site-specific tolerance limits is helpful to investigate the cause of out-of-control VMAT QA.

    Release date:2020-12-14 05:08 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content