west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "tricuspid valve repair" 3 results
  • Functional tricuspid regurgitation: Current understanding

    Functional tricuspid regurgitation is referred to tricuspid regurgitation due to enlargement of right ventricular and dilation of tricuspid annulus. Patients with chronic progressive tricuspid regurgitation have poor prognosis, poor quality of life and heavy economic burden. This article provides a comprehensive review of functional tricuspid regurgitation in terms of anatomical basis, pathological stage, imaging assessment and surgical decision making.

    Release date:2020-06-29 08:13 Export PDF Favorites Scan
  • Reoperative strategy and mid- to long-term surgical outcomes of Ebstein anomaly

    ObjectiveTo analyze the Ebstein anomaly's reoperative strategy and mid- to long-term results.MethodsWe retrospectively reviewed the clinical data of 23 patients who diagnosed with Ebstein anomaly and underwent reoperation for tricuspid valve insufficiency between July 2002 and July 2017 in Fuwai Hospital. There were 9 (39.1%) males and 14 (60.9%) females, with a median age of 28.0 (19.0, 45.0) years.ResultsAmong the 23 patients, 8 (34.8%) underwent tricuspid valvuloplasty and 15 (65.2%) underwent tricuspid valve replacement. The rate of valvuloplasty was 16.7% before 2012, and 54.5% after 2012 (P=0.089) as Cone reconstruction procedure was used. In the valvuloplasty cohort, 3 (37.5%) patients were treated with Danielson or Carpentier technique, and 5 (62.5%) patients were treated with Cone reconstruction procedure. There was no operation-related death. Early complications occurred in 3 (37.5%) patients. The median follow-up was 6.9 years (range, 3.0-15.1 years), and no adverse cardiac events occurred. In the patients with valve replacement, 7 (46.7%) received mechanical prosthesis and 8 (53.3%) received bio-prosthesis. There was no operation-related death. And early complications were observed in 3 (20.0%) patients. The median follow-up was 6.5 years (range, 2.5-15.3 years). One (6.3%) patient died and 4 (26.7%) had long-term complications during the follow-up period.ConclusionThe mid- to long-term outcomes are convincing in patients who undergo the second operation due to recurrent tricuspid regurgitation of Ebstein anomaly. A low incidence of reoperation is observed. Cone reconstruction procedure provides possibilities of second tricuspid valvuloplasty, and this technique can reduce the rate of tricuspid valve replacement in the second operation. Tricuspid valve replacement is still an alternative method for the treatment of recurrent tricuspid regurgitation in patients with Ebstein anomaly. The bioprosthetic prosthesis may be a better choice than mechanical prosthesis.

    Release date: Export PDF Favorites Scan
  • Concomitant repair of moderate or less tricuspid regurgitation during mitral valve surgery improves early and mid-term prognosis of tricuspid valve and right heart function

    ObjectiveTo investigate the effect of concomitant tricuspid valve repair during mitral valve surgery on the early and mid-term prognosis of the tricuspid valve and right heart function in the patients with moderate or less tricuspid regurgitation. MethodsA retrospective study of 461 patients with mitral valve disease requiring cardiac surgery combined with moderate or less tricuspid regurgitation in our hospital from 2011 to 2014 was done. They were 309 males and 152 females with a median age of 53.00 (44.00, 60.00) years. According to whether they received tricuspid valve repair (Kay’s annuloplasty, DeVega’s annuloplasty or annular ring implantation), the patients were divided into a mitral valve surgery only group (a nTAP group, n=289) and a concomitant tricuspid valve repair group (a TAP group, n=172). At the same time, 43 patients whose tricuspid valve annulus diameter was less than 40 mm in the TAP group were analyzed in subgroups. ResultsThe median follow-up duration was 3.00 years (range from 0.10 to 9.30 years). There was no perioperative death. Three months after surgery, the anteroposterior diameter of the right ventricle in the TAP group was significantly improved compared with that in the nTAP group [–1.00 (–3.00, 1.00) mm vs. 0.00 (–0.20, 2.00) mm, P=0.048]. Three years after surgery, the improvement of right ventricular anteroposterior diameter in the TAP group was still significant compared with the nTAP group [–1.00 (–2.75, 2.00) mm vs. 2.00 (–0.75, 4.00) mm, P=0.014], and the patients in the TAP group were less likely to develop moderate or more tricuspid regurgitation (3.64% vs. 35.64%, P<0.001). Annuloplasty ring implantation was more effective in preventing regurgitation progression (P=0.044). For patients with a tricuspid annulus diameter less than 40 mm, concomitant tricuspid valve repair was still effective in improving the anteroposterior diameter of the right ventricle in the early follow-up (P=0.036). Conclusion Concomitant tricuspid valve repair for patients with moderate or less tricuspid regurgitation during mitral valve surgery can effectively improve the tricuspid valve and right heart function in the early and mid-term after surgery. Annuloplasty ring implantation is more effective in preventing regurgitation progression. Patients whose tricuspid annulus diameter is less than 40 mm can also benefit from concomitant tricuspid repair.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content