Objective To review the progress of the robotic applications in vascular surgery. Methods Recent literature about the robotic applications in vascular surgery was reviewed and analyzed. Results Robotic system is composed of surgery robotic system and endovascular interventional robotic system. The time of aortic clamping and anastomosis is reduced considerably during the robotic-assisted aorta bypass surgery, and the dissection of aorta is completed successfully in totally robotic approach. Endovascular interventional robotic system has good performance in navigation and stability, and shows apparent advantages in passing special anatomical segment and complicated lesion. However, the robotic systems are still limited in application for high cost. The problem of tactile feedback should also be solved quickly. Conclusion Robotic systems have apparent advantages and good prospect in vascular surgery. Nevertheless, it still require many clinical trials to formulate the indication and contraindication, to establish standard procedure, to assess the long-term effectiveness of the robotic systems and so on.
ObjectiveTo evaluate the effectiveness of covered Cheatham-platinum (CP) stent for treatment of coarctation of aorta (CoA). MethodsBetween January 2007 and September 2013, 15 patients (16 lesions) with CoA underwent covered CP stent implantation, and the clinical data were analyzed retrospectively. Of 15 cases, 8 were male and 7 were female, aged 13-56 years (mean, 27.7 years). Fifteen lesions located beyond the origin of the left subdavian artery, and 1 lesion located between the origin of the left common carotid artery and the origin of the left subdavian artery. Proper covered CP stent and balloon-in-balloon (BIB) catheter were selected according to the data of computed tomography angiography or digital subtraction angiography examination. Under fluoroscopic guidance, the covered CP stent was placed at lesion accurately by expanding the inner balloon and the outer balloon sequentially. The variation of the systolic pressure gradient across the lesion and the stenosis extent of the aorta before and after the procedure were recorded. ResultsFifteen patients were all treated by covered CP stent implantation successfully. The systolic pressure gradient across the lesion decreased from (58.1±19.5) mm Hg (1 mm Hg=0.133 kPa) at preoperation to (6.2±5.6) mm Hg at immediate after CP stent implantation, and the stenosis extent of the aorta decreased from 73.8%±12.8% at preoperation to 16.7%±5.6% at immediate after CP stent implantation, all showing significant difference (t=12.483, P=0.000; t=15.631, P=0.000). All puncture points healed well with no aortic dissection, pseudoaneurysm, or obvious subcutaneous hematoma. All the patients could walk moderately within 48 hours after procedure. The average hospitalization time was 11.1 days (range, 6-18 days). During a mean follow-up of 29.7 months (range, 1-81 months), the symptom of dizziness and exercise tolerance were improved obviously, and the systolic pressures gradient between upper and lower extremity was below 20 mm Hg. The systolic and diastolic pressures at last follow-up were significantly improved when compared with preoperative values (t=7.725, P=0.000; t=3.651, P=0.000). According to radiography, the location and shape of the stent were good, and no aortic dissection, aneurysm, or recoarctation occurred. ConclusionAccording to the initial and midterm results, the covered CP stent is an effective treatment for CoA in adolescents and adults with a low rate of complication. However, long-term results still require further follow-up.
ObjectiveTo evaluate the efficacy and safety of intracavitary treatment for iliac vein compression syndrome(IVCS)with acute lower extremity deep venous thrombosis (DVT).MethodsThe clinical data of 57 patients with IVCS and lower extremity DVT, who undergoing with stent implantation, balloon expansion and Angiojet rheolytic thrombectomy from June 2015 to June 2018, were retrospectively analyzed. The effect of treatment was evaluated by the changes of thigh circumference difference between the affected side and the healthy side, and the thrombosis clearance rate in the operating. In addition, the incidence of post-thrombotic syndrome (PTS) and stent patency rate were analyzed after long-term follow-up based on the change of Villaita scale score and ultrasound examination of lower extremity veins.ResultsThe success rate of surgical technique was 100%, and there was no pulmonary embolism during operating and postoperative. Lower extremity deep vein thrombosis clearance levels Ⅲ 48 cases (84.2%), Ⅱ 9 cases (15.8%), the changes of thigh circumference difference between the affected side and the healthy side from preoperative (5.8±1.7) cm to (3.7±1.0) cm. One year follow-up after operation, the primary patency rate of stent was 86.0% and PTS occurred in 8 patients (14.0%).ConclusionStent implantation, balloon expansion and Angiojet rheolytic thrombectomy for IVCS with acute lower extremity DVT is a safe, effective with low incidence of complications and efficient thrombus clearance.
As one of the stimulus-response polymeric intelligent materials, shape memory polymers have been widely applied in biomedicine due to their better biocompatibility, higher controllability, stronger deformation restorability and biodegradability compared with shape memory alloys and shape memory ceramics. This review will introduce the structural principles of shape memory polymers and summarize their applications in the treatment of vascular diseases, especially in endovascular therapy. At the same time, the related technical problems and the future of shape memory polymers are prospected. With the continuous development of processing technology and materials, it can be predicted that shape memory polymers will be more widely used in the medical field.
Early endovascular interventional therapy can effectively improve the prognosis of patients with acute ischemic stroke. Dual-source CT dual-energy scanning, as a new CT imaging technology developed rapidly in recent years, with its unique technical characteristics and advantages, shows potential and application prospects in early endovascular interventional therapy of acute ischemic stroke. This article discusses the value of dual-source CT dual-energy scanning in the early screening and evaluation, the identification of postoperative iodine contrast agent extravasation and secondary cerebral hemorrhage, and the prediction of prognosis of patients with early endovascular interventional treatment of acute ischemic stroke. The purpose is to provide a theoretical basis for better application of dual-source CT dual-energy scanning in early endovascular interventional treatment of acute ischemic stroke.