Objective To evaluate the clinical effect of Halo-vest in treatment of unstable upper cervical spine. Methods From March 1997 to October 2002, 16 cases of unstable upper cervical spineswere treated and immobilized by Halovest, aged from 14 to 53 years. There were 3 cases of isolated Jefferson fractures, 4 cases of isolated Hangman fractures and 1 case of Anderson type Ⅱ fracture. The 8 cases were immobilized for 3-4 months by Halovest. There were 3 cases of old odontoid fractures with dislocations treated by occipitocervical plate fixation and fusion, 1 case of C1 malignant tumor by posterior resection and internal fixation, 2 cases of C2 malignant tumor by anterior resection, fusion, and internal fixation; these cases were immobilized by Halo-vest during surgery. There were 1 case of C2,3 tuberculosis were treated by anterior debridement and fusion, and 1 case of gooseneck deformity by anterior decompression, fusion and screw fixation after resection of C2-7 , the 2 cases were immobilized for 3 months by Halo-vest.Of 16 cases, there were 8 cases accompanied with spinal cord syndrome. Results Fifteen cases were followed up 6 months to 5 years. Anterior arch ununion and posteriorarch osseous healing occurred in 1 case of Jefferson fracture. Other fractures and embedded bones became osseous fusion. One case of C2 malignant tumorrecurred 8 months after operation. Spinal cord syndrome of all patients disappeared. Conclusion Halo-vest immobilization is an effective method for conservative treatment and stable reconstruction of unstable upper cervical spine.
Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. The use of new heart valves prosthesis has improved surgical safety and efficacy. This report described a 72-year-old male patient with severe aortic stenosis combined with severe aortic regurgitation, who was evaluated at moderate-high risk of surgery and received a transapical TAVR using the Ken-Valve heart valve. The transcatheter operation time was 8 min, and the blood loss was 50 mL. The tracheal intubation was removed immediately after the surgery. Transesophageal echocardiography on the 4th postoperative day showed that the aortic valve leaflets worked well, and there was no valve orifice and paravalvular leakage. The patient was discharged on the 5th day after the surgery without complications. Transapical TAVR using Ken-Valve was an easy surgical procedure for aortic valve disease, and had short operation time.
Objective To study the cl inical effects of modified Galveston technology in the treatment of lumbosacral tuberculosis. Methods From January 2001 to May 2008, 19 patients with lumbosacral tuberculosis were treated, including13 males and 6 females aged 21-58 years old (average 38 years old). The course of disease was 8-22 months. The tuberculosis was at the L4-S1 level in 3 cases, the L5, S1 level in 10 cases, the L5-S2 level in 5 cases, and the S1, 2 level in 1 case. Seven cases were compl icated with neural symptom of the lower l imbs, 3 cases of them were grade C and 4 cases were grade D according to the Frankel scale of nerve function. The preoperative JOA score of lower back pain was 5-22 (average 19). Six cases were compl icated with il iac abscess, 3 cases with psoas abscess, 3 cases with sacroil iac joint tuberculosis, and 2 cases with pulmonary tuberculosis. For 12 patients, the operation of modified Galveston internal fixation via the posterior approach, focus debridement via vertebral canal, and interbody fusion with autogeneous il iac bone fragment grafting was performed; for 7 cases, the operation of modified Galveston internal fixation via the posterior approach, vertebral lamina fusion with autogeneous il iac bone fragment grafting, and anterior focus debridement was performed. Results The incision of 18 cases was healed by first intention, and 1 case had sinus 3 weeks after operation and healed 3 months after operation. Nineteen patients were followed up for 12-82 months (average 21 months). There was no recurrence of the local tuberculosis, and the common toxic symptom of tuberculosis disappeared 6-12 months after operation. All the patients achieved bony fusion 4-6 months postoperatively, and 3 patients with sacroil iac joint tuberculosis achieved sacroil iac joint fusion. For those 7 patients with combinations of the neural symptomof the lower l imbs, the symptoms disappeared and their Frankel scales were improved to grade E. The JOA score of low back pain at the final follow-up was 22-29 (average 26). There was a significant difference between preoperation and postoperation (P lt; 0.05). Conclusion The modified Galveston technology is helpful to reconstruct the stabil ity of lumbosacral vertebrae, improve bony fusion rate, reduce the postoperative in-bed time.
ObjectiveTo explore the clinical value of modified Soave procedure with stapler for the treatment of Hirschsprung disease. MethodsThe clinical data of 26 patients with Hirschsprung disease adimitted in No.477 hospital from January 2002 to December 2010 were analyzed retrospectively. All the patients underwent modified Soave operation with rectal mucosa and proximal intestine stapled end-to-end. ResultsAll operations were successful without anastomotic leakage, aponeurosis of investment infection, and colonitis. Increased stool frequency presented in two cases, which were cured with astringents on day 15 and 30 after operation, respectively. Mild fecal contamination was in one case. All cases were followed up between 3 months to 60 months, with an average 32 months, without incontinence and constiptation. ConclusionModified Soave procedure with stapler is safe and effective for the treatment of Hirschsprung disease in elder children and adult.
ObjectiveThe aim of this study was to investigate the pathogenesis of AED-induced SJS/TEN across the spectrum of HLA-A, -B and -DRB1 alleles, and to explore the different clinical characteristics of patients with and without the HLA-B*15:02 allele in the SJS/TEN group. MethodsA total of twenty-three patients exhibiting AED-induced SJS/TEN (16 CBZ-SJS/TEN, seven LTG-SJS/TEN) and fifty-two patients who exhibited tolerance to AEDs were recruited. High-resolution HLA genotyping was performed to estimate the prevalence of the HLA-A, -B and -DRB1 alleles for each subject. Patients in the SJS/TEN group were further divided to positive HLA-B*15:02 allele group and negative HLA-B*15:02 allele group depending on whether carrying the HLA-B*15:02 allele, and the clinical feathers were compared between the two groups. ResultsNine of twenty-three patients (39%) in the SJS/TEN group were male, and the mean age of this group was 32 (8-68) years old. Twenty-eight of fifty-four (54%) patients in the tolerant group were male, and the mean age of the tolerant group was 28 (9-64) years old.Fourteen subjects in the SJS/TEN group carried the HLA-B*15:02 allele, whereas only four subjects (7.7%) in the AED-tolerant group carried this allele; the carrier rate of HLA-B*15:02 was significantly different between the groups (P<0.001). Among the fourteen patients who carried the HLA-B*15:02 allele in the SJS/TEN group, composing the positive HLA-B*15:02 allele group, eight patients (57.1%) were female, whereas six of nine patients in the negative HLA-B*15:02 allele group were female. The difference of the gender didn't have statistical significance between the two groups, nor did the other clinical characteristics, including mean age, the dosage of the AEDs, the interval from the drug administration to the onset of the SJS/TEN, fever, allergic history, abnormal MRI and abnormal EEG results. ConclusionsThe pathogenesis of AED-induced SJS/TEN is a complex process, which may involve one or more alleles. The HLA-B*15:02 allele may be a genetic susceptibility factor of the AED-induced SJS/TEN. However, we didn't find significant difference of the clinical characteristics of SJS/TEN between the patients with and without the HLA-B*15:02 allele. Notably, further studies using larger samples are required to confirm these conclusions.
Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.
ObjectiveTo investigate the operative method and short-term effectiveness in the surgical treatment of Maisonneuve fracture. MethodsBetween January 2010 and February 2013, 23 patients with Maisonneuve fracture were treated. There were 14 males and 9 females with an average age of 40.3 years (range, 30-68 years). The causes of injuries were falling injury in 11 patients, sports related injury in 5 patients, traffic accident injury in 4 patients, and falling injury from height in 3 patients. The interval between injury and operation was 7-10 days (mean, 8.5 days). All of fractures were closed. Three patients had combined injury of deltoid ligament. The surgical procedures included surgical reduction and fixation of medial malleolus fracture and posterior malleolus fracture, repair of the deltoid ligament with ground anchor suture, and fixation of the disrupted distal tibiofibular syndesmosis. ResultsAll incisions achieved primary healing, no postoperative complications such as infection occurred. Twenty-one patients were followed up 24-36 months (mean, 26.5 months). No patients complained of pain, tenderness, and obvious swelling of the ankle. At 3-6 months (mean, 4.6 months) after operation, X-ray films showed bony union of fractures and normal mortises in 21 patients. And no traumatic arthritis was observed with reliable fixation. The range of motion of ankle dorsi flexion and plantar flexion was 30-40° (mean, 34.5°). Baird-Jackson ankle functional score was 85-100 (mean, 94); 16 cases were rated as excellent, 4 as good, and 1 as fair with an excellent and good rate of 95.2%. ConclusionSurgical treatments of Maisonneuve fracture include surgical reduction and fixation of the medial malleolus and posterior malleolus, repair of the deltoid ligament and fixation of the disrupted distal tibiofibular syndesmosis, and good effectiveness can be achieved.
Objective To investigate the early safety and efficacy of transapical transcatheter aortic valve implantation (TAVI) for high-risk elderly patients with pure aortic valve insufficiency. Methods A prospective multicenter clinical study of domestic J-valveTM TAVI for high-risk native non-calcified aortic valve insufficiency was conducted from April 2014 to May 2018, and the early postoperative results were analyzed. A total of 82 patients were enrolled, including 62 patients from West China Hospital, Sichuan University, 16 patients from Zhongshan Hospital, Fudan University, and 4 patients from Beijing Fuwai Hospital, National Center for Cardiovascular Diseases. There were 55 males and 27 females. The age was 61-90 (73.8±6.3) years. The logistic EuroSCORE was 10.0%-44.4% (17.5%±8.1%). All patients underwent TAVI using J-ValveTM system. Clinical evaluation and echocardiography were performed preoperatively and 1 month postoperatively. Multislice spiral CT was reviewed before discharge. Results Three patients were transferred to thoracotomy for cardiopulmonary bypass operation, and 1 patient had decreased cardiac function due to leakage of the valve 1 week after surgery. The overall technical and procedural success rate was 95.1% and 93.9%, respectively. During hospitalization, 1 patient died of moderate pericyclosis complicated with multiple organ failure, and 1 patient died of pulmonary infection. Six (7.6%) patients received pacemaker implantation due to new onset Ⅲ° atrioventricular block. Echocardiographic follow-up showed paravalvular leak was observed in the few of patients, mild paravalvular leak was in 13 patients on the 30th day. Two patients showed moderate paravalvular leak. Left ventricular end-diastolic volume decreased from 197.7±66.8 mL (pre-TAVI) to 147.2±53.3 mL (30-day post-TAVI) (P<0.05). Mean pressure gradient was 9.5±4.1 mm Hg (30-day post-TAVI). Conclusion This multicenter study demonstrates that TAVI with the J-Valve system for the treatment of pure aortic regurgitation is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic regurgitation early-term follow-up. Our results further support that TAVI with the specific designed J-Valve system is an acceptable alternative therapy for high-risk patients with pure AR. Our result demonstrates good early-term durability and preserved hemodynamic function. The procedure appears to offer an adequate and lasting resolution for selected patients with pure aortic regurgitation.
ObjectiveTo compare the radiation dose distribution in irradiated target area and organs at risk among conventional radiotherapy, conformal radiotherapy and semi-field conformal radiotherapy in Graves' ophthalmopathy patients. MethodsThirty patients with Grave's ophthalmopathy treated between January 2010 and December 2012 were included in this study.CT scan was performed to obtain images of each patients; three-dimensional planning system (3D-TPS) was done to design conventional radiotherapy, conformal radiotherapy and semi-field conformal radiotherapy for each patient.Then, we counted the standard deviation of study parameters for each radiotherapy technique, and the results were compared among the three groups. ResultsAverage irradiation dose in target area of patients accepting conventional irradiation, conformal irradiation and semi-field conformal irradiation therapy was not significantly different (P > 0.05).V95 and the conformity index values of conformal irradiation and semi-field conformal irradiation therapy were better than those of the conventional irradiation therapy (P < 0.001), while no significant difference between conformal irradiation and semi-field conformal irradiation therapy was detected (P > 0.05).Patients accepting conventional irradiation got the highest cumulative irradiation dose in eye lens, while patients accepting semi-field conformal irradiation therapy got the lowest irradiation dose in eye lens, and the differences were significant (P < 0.05).Patients accepting conventional irradiation got the highest cumulative irradiation dose in pituitary, while cumulative irradiation dose in pituitary in patients accepting conformal irradiation and semi-field conformal irradiation therapy was not significantly different (P > 0.05). ConclusionsConformal irradiation and semi-field conformal irradiation techniques are superior to conventional irradiation technique, with a better target conformal degree and higher does distribution in target area, as well as a lower radiation dose in normal tissues surrounding target area.Semi-field conformal irradiation technique has a better performance than conformal irradiation therapy in eye lens protection.
ObjectiveTo review the research progress of different ways of stem cells generation and cells dedifferentiation induced by reversine. MethodsThe papers related to reversine inducing cells dedifferentiation and stem cells generation were reviewed. ResultsTo obtain stem cells, there are always some disadvantages via somatic cell nuclear transfer or gene transfection. However reversine, a small molecule, can induce cells dedifferentiation which has unique advantage. But its mechanism is still unclear. ConclusionThe chemical approach for generation of induced pluripotent stem cells by reversine may take the place of other methods.