west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "ventral hernia" 3 results
  • APPLICATION OF COMPOUND REPAIR FOR RECONSTRUCTION OF ABDOMINAL WALL IN PATIENTS WITH GIANT LOWER VENTRAL HERNIA

    Objective Surgical repair for giant lower ventral hernia is facing challenge owing to enormous tissue defect and the critical structures of pubis and il iac vessels. To investigate the method and curative effect of intraperitoneal onlay mesh (IPOM) combined with Sublay for compound repair of giant lower ventral hernia. Methods Between November 2008 and August 2010, 26 patients with giant lower ventral hernia were treated. There were 15 males and 11 females with an averageage of 61 years (range, 36-85 years), including 11 cases of lower midl ine incisional hernia due to radical rectal procedures, 6 cases of Pfannenstiel incisional hernia due to radical uterectomy, and 9 cases of lower midl ine incisional hernia due to radical cystectomy. Of them, 11 patients underwent previous repair procedures. The mean time from hernia to admission was 8.5 years (range, 1-15 years). All hernias were defined as M3-4-5W3 according to classification criteria of Europe Hernia Society. The mean longest diameter was 17.5 cm (range, 13-21 cm) preoperatively. Before 2 weeks of operation, abdominal binder was tightened gradually until the contents of hernia sac were reduced totally, and then reconstruction of abdominal wall was performed with compound repair of IPOM and Sublay technique. Results All of compound repair procedures were performed successfully. The mean hernia size was 112.5 cm2 (range, 76.2-160.6 cm2); the mean polypropylene mesh size was 120.4 cm2 (range, 75.3-170.5 cm2); and the mean compound mesh size was 220.0 cm2 (range, 130.4-305.3 cm2). The mean operative time was 155.5 minutes (range, 105.0-195.0 minutes) and the mean postoperative hospital ization time were 12 days (range, 7-16 days). Incisions healed by first intention; 4 seromas (15.4%) and 3 chronic pains (11.5%) occurred and were cured after symptomatic treatment. All patients were followed up 3-24 months (mean, 14.5 months). No recurrence and any other discomforts related to repair procedure occurred. Conclusion Compound repair of IPOM and Sublay is a safe and efficient surgical procedure for giant lower ventral hernia, owing to its characteristics of adequate patch overlap and low recurrence rate. Perioperative management and operative technology play the key role in the success of repair procedure.

    Release date:2016-08-31 05:43 Export PDF Favorites Scan
  • Curative effect analysis of three mesh positions for treatment of ventral hernia

    ObjectiveTo study the clinical efficacy of three mesh positions for treatment of ventral hernia.MethodsThe data of 87 patients undergoing abdominal incision hernia repair from January 2015 to January 2017 in the First Affiliated Hospital of Zhengzhou University were analyzed respectively. They were divided into three groups according to the different mesh position, Onlay treatment (n=28), Inlay treatment (n=27) and Sublay treatment (n=32). The curative effect and complications of three different surgical methods were compared and analyzed.ResultsAll the patients were recovered and discharged. A total of 6 cases among 87 patients had incision fat liquefaction, 1 patient had superficial infection and 2 patients had postoperative incision hematoma. After 3 to 36 months of follow-up (average 8 months), 3 cases of 87 patients recurred.ConclusionsThree kinds of surgeries for ventral hernia are feasibility and value, Sublay treatment is not only less pain and complications but more effective. We should strengthen the screening of preoperative cases and selecting appropriate surgical methods to prevent and reduce the recurrence of hernia.

    Release date:2021-02-02 04:41 Export PDF Favorites Scan
  • Risk and benefit evaluations of biological versus synthetic mesh for ventral hernia repair: a meta-analysis

    ObjectiveTo systematically evaluate the effects of biological mesh (BM) and non-absorbable synthetic mesh (SM) on the risks of recurrence, complications, and cost-effectiveness after ventral hernia repair. MethodsThe publicly published related researches of BM versus SM for ventral hernia repair were searched in the PubMed, Cochrane Library, Embase, Web of Science, CNKI, Wanfang, VIP, CBM databases from the establishment of the databases to August 1, 2021. According to the inclusion and exclusion criteria, the literatures were screened and the data were extracted, and the data that met the conditions were merged and analyzed. The meta-analysis was performed by RevMan5.4.1 software. ResultsA total of 26 studies with 3 259 patients were included, including 1 388 patients in the BM group and 1 871 in the SM group. The results of meta-analysis showed that the recurrence, surgical site infection, surgical site occurrence, reoperation rates, and medical costs in the BM group were higher than those in the SM group (P<0.05). There were no significant differences in the patch infection, seroma, hematoma, wound dehiscence, and readmission rates between the two groups (P>0.05). ConclusionsSM during ventral hernia repair is better than BM on postoperative recurrence, surgical site infection, surgical site occurrence, reoperation, etc., and could reduce medical costs. In the future, it is tried to use more SM in patients with complicated ventral hernia such as cleaning pollution and contaminated environment.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content