Objective To investigate the effects of exogenous pulmonary surfactant (PS) on ventilation weaning and respiratory mechanics in infants with acute lung injury(ALI) after cardiopulmonary bypass (CPB).Methods Twelve infants underwent cardiopulmonary bypass cardiac surgery committed with ALI and difficulty in weaning from ventilation were included in this study.Exogenous PS was used in the treatment via intra-tracheal administration.The changes of blood gas,respiratory mechanics and the conditions of ventilation weaning were observed.Results After intra-tracheal PS administration,spontaneous breath remained steady;spontaneous respiratory rate significantly decreased from,tidal volume of spontaneous breath increased significantly.Three concave sign disappeared and koilosternia was alleviated.PaCO2 value decreased significantly and peak inspiratory pressure(PIP) decreased from (36.18±10.25)cm H2O to (25.11±5.14)cm H2O (Plt;0.01).Static lung compliance (Cstat) increased from (1.49±0.65)mL·cm H2O-1·kg-1 before treatment to (1.95±0.50) mL·cm H2O-1·kg-1 6 h after treatment (Plt;0.01);and airway resistance (Rstat)decreased from (128.17±26.34) cm H2O·L-1·s-1 before treatment to (78.56±18.22) cm H2O·L-1·s-1 6 h after treatment (Plt;0.01).All 12 infants weaned from ventilator successfully.Conclusion Combined with PS intra-tracheal treatment,lung protective ventilation strategy can significantly improve parameters of respiratory mechanics,increase dynamic lung compliance,decrease airway resistance,which can decrease the breathing effort of the infants and make it easy to wean from ventilator.
Objective To study the influencing factors for duration of mechanical ventilation in chronic obstructive pulmonary disease ( COPD) patients with type II respiratory failure. Methods Twenty-eight cases of mechanical ventilated COPD patients with type II respiratory failure were enrolled from March 2006 to March 2008 in Beijing Shunyi Hospital. They were divided into two groups based on their duration of ventilation: ≤7 d group as group I, and gt; 7 d as group II. Data of heart rate and blood pressure were recorded before the trachea intubation. Clinical data of blood routine, blood gas analysis and serum biochemistry were collected and analyzed. Previous history, smoking history and subsequent complications were also recorded. Results Heart rate in the group II were significantly higher than which in the group I[ ( 121. 50 ±17. 20) /min vs ( 103. 08 ±19. 97) /min, P lt;0. 05] . The incidences of upper gastrointestinal hemorrhage and blood pressure fall immediately after intubation were 63% and 88% respectively in the group II, which were significantly higher than the group I ( 0 and 25% ) . The levels of albumin, pre-albumin, Na+ , PaO2 were ( 29. 06 ±5. 00) g /L, ( 66. 36 ±17. 72) mg/L,( 138. 45 ±4. 74) mmol /L and ( 49. 06 ±20. 11) mm Hg respectively in the group II. While in the group I, those were ( 37. 11 ±2. 73) g /L, ( 127. 70 ±35. 84) mg/L, ( 143. 29 ±3. 42) mmol /L and ( 72. 25 ±38. 69) mm Hg respectively, which showed significant differences compared with the grouop II. The incidence of previous concomitant cerebral infarction showed significant difference between the group I and group II( 33. 33% vs 0) .Conclusion The levels of albumin, pre-albumin, heart rate before the intubation, upper gastrointestinal hemorrhage and blood pressure fall immediately after the intubation are associated with duration of mechanical ventilation and may indicate the prognosis in COPD patients with type II respiratory failure.
Objective To determine the usefulness of serial measurements of the rapid shallow breathing index ( f/VT , RSBI) as a predictor for successfully weaning of patients undergoing prolonged mechanical ventilation ( gt; 72 hours) . Methods 76 mechanically ventilated patients were prospectively analyzed. 120-min spontaneous breathing trial was conducted after the patients having fullfiled the traditional weaning criteria, and RSBI were continuously monitored by the ventilator at five time points ( 5, 15, 30,60, and 120 min) . A repeated measure of general linear model in SPSS 15.0 was conducted to analyze the data. Results 62 patients completed 120-minute spontaneous breath trial and in which 20 patients failed weaning. There was no significant difference of RSBI at five time points during weaning ( P gt;0. 05) . But thevariation trends of RSBI during weaning time were significant different between the successful weaning patients and the failed weaning patients ( P lt; 0. 05) . Conclusions In patients undergoing prolonged mechanical ventilation, the variation trend of RSBI is more valuable than single RSBI in the prediction ofsuccessful weaning.
Objective To estimate the feasibility and efficacy of respiratory function score ( RFS)guided ventilator weaning in mechanical ventilated patients with respiratory failure. Methods By a prospective control study,136 patients with acute respiratory failure who had received endotracheal intubation and mechanical ventilation from January 2010 to May 2012 were randomly divided into three group, ie. a RFS-guided 3-4 group ( n=60) , a RFS-guided 5-6 group ( n = 51) , and a traditional group ( n =25) . TheRFS-guided groups underwent ventilator weaning by guidance of RFS 3-4 and 5-6 respectively. The traditional group underwent ventilator weaning by ordinary way. The ventilation and oxygenation index, RFS,direct weaning success rate, total weaning success rate, total mechanical ventilation time, re-intubation rate,and ventilator-associated pneumonia ( VAP) incidence rate were observed.Results The direct weaning success rate in the RFS-guided 3-4 group, the RFS-guided 5-6 group, and the traditional group was 98. 3%( 59/60) , 82. 4% ( 42 /51) , and 100% ( 25 /25) , respectively. The total duration of mechanical ventilation was ( 5. 2 ±2. 5) days, ( 5. 0 ±3. 0) days, and( 7. 5 ±3. 5) days, respectively. the re-intubation rate was 0( 0 /60) , 1. 9% ( 1 /51) , and 0 ( 0/25) , respectively. VAP incidence rate was 11. 7% ( 7/60) , 13. 7%( 7 /51) and 24% ( 6 /25) , respectively. Compared with the traditional group, the direct weaning success rate and total weaning success rate in the RFS-guided 3-4 group were not significant different( P gt;0. 05) , while the total mechanical ventilation time and VAP incidence rate were significantly lower ( P lt; 0. 05) . Compared with the traditional group, the direct weaning success rate and total mechanical ventilation time in the RFSguided 5-6 group were significantly lower ( P lt;0. 05) , but the total weaning success rate was not significantly different ( P gt;0. 05) . Compared with the RFS-guided 5-6 group, the directweaning success rate in the RFSguided 3-4 group was significantly increased. Conclusions Mechanical ventilator weaning of patients with respiratory failure under RFS guidance is safe and feasible. RFS 3-4 guided ventilator weaning can significantly improve the therapeutic effect.
Objective To compare the advantages between SmartCare weaning and protocoldirected weaning in COPD patients regarding five aspects including comfort degree of COPD patients in weaning stage, workload of medical staff, weaning success rate, weaning time, and complications associated with mechanical ventilation. Methods COPD patients who’s planning to receive ventilation weaning were randomly divided into a SmartCare weaning group ( SC group) and a protocol-directed weaning group ( SBT group) . The comfort degree of patients and workload of medical staff were assessed by the visual analogue scale ( VAS) as the weaning plan started. 0 was for the most discomfort and maximal workload, and 10 was for the most comfort and minimal workload. Data fromthe following aspects had been recorded: times of blood gas analysis, weaning success rate, weaning time, self-extubation rate, the rate of re-intubation within 48 hours, and ventilator-associated pneumonia ( VAP) incidences. Results 40 patients were selected and divided into the SC group ( n =19) and the SBT group ( n =21) . There was no significant difference in the enrolled age and APACHEⅡ between two groups. The VAS scores was higher in the SC group than that in the SBT group in the first three days ( Plt;0.01) . The weaning time was shorter in the SBT group than that in the SBT group [ ( 4.7 ±2.7) days vs. ( 5.5 ±3.2) days] , without significant difference between two groups ( P gt;0.05) . There were no differences in times of blood gas analysis, weaning success rate, weaning time, self-extubation rate, the rate of re-intubation within 48 hours, and ventilator-associated pneumonia ( VAP) incidences between two groups ( P gt; 0.05) .Conclusion As compared with protocol-directed weaning, SmartCare weaning can increase comfort degree of patients and reduce the workload of medical staff with similar weaning success rate, weaning time, and complications associated with mechanical ventilation.
ObjectiveTo investigate the risk factors associated with failure of weaning from invasive mechanical ventilation in gerontal patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). MethodsA retrospective study was conducted on 76 patients aged 65 years and older with AECOPD who received invasive mechanical ventilation and met the weaning criteria from July 2012 to June 2014. The subjects who passed the spontaneously breathing trial (SBT) and did not need mechanical ventilation within 48 h were enrolled into a weaning success group. The subjects who did not pass the SBT or needed mechanical ventilation again within 48 h were enrolled into a weaning failure group. The risk factors associated with failure of weaning were studied by univariate and multivariate Logistic regression analysis. ResultsThere were 53 subjects in the weaning success group and 23 in the weaning failure group. The incidences of sepsis, multiple organ dysfunction syndrome (MODS), fungal infection, hypoproteinemia, duration for mechanical ventilation > 14 d, the prevalences of aeropleura, cardiac failure, diabetes, coronary heart disease and hepatic insufficiency were higher in the weaning failure group than those in the weaning success group (P < 0.05). Logistic analysis revealed that MODS (OR=8.070), duration for mechanical ventilation > 14 d (OR=17.760), cardiac failure (OR=4.597) and diabetes (OR=13.937) were risk factors of weaning failure (P < 0.05). ConclusionMODS, duration for mechanical ventilation > 14 d, cardiac failure and diabetes were associated with the failure of weaning from invasive mechanical ventilation in gerontal patients with AECOPD.
ObjectiveTo improve the understanding of prolonged weaning. MethodsA clinical case of prolonged weaning who had been successfully weaned from mechanical ventilation was retrospectively analyzed. The related literature was also reviewed. ResultsThe patient received invasive mechanical ventilation for 5 months,diagnosed as ventilator-associated pneumonia,type Ⅱrespiratory failure,Green-Barry syndrome,hypoproteinemia,anemia,and electrolyte disorder. Through the control of infection,nutritional support,psychological counseling,the patient was weaned from ventilator gradually and succeeded eventually. ConclusionsProlonged weaning is relatively difficult and wastes a long time. Professional treatment team and specialized treatment room are necessory. There are few reports about prolonged weaning.
Objective To investigate the clinical significance of lateral position ventilation in the treatment of invasive ventilation in patients with acute exacerbations of chronic obstructive pulmonary disease (AECOPD). Methods From October 2014 to December 2016, 60 eligible patients with AECOPD who meeting the inclusion criteria were randomly assigned to an intervention group (n=30) or a control group (n=30). Expectorant, antiasthmatic, anti-infective, invasive ventilation, bronchoscopy, analgesic sedation, invasive-noninvasive sequential ventilation, nutritional support, intensive care and other treatment were conducted in two groups, but lateral position ventilation was subsequently performed in the intervention group and the control group used half lateral position. Outcome measurements included pH, PaO2/FiO2, arterial partial pressure of carbon dioxide (PaCO2), heart rate (HR), respiratory rate (R) and air way resistance (Raw) before and one day after invasive ventilation, and duration of control of pulmonary infection (PIC), invasive mechanic ventilation (IMV), mechanic ventilation (MV) and intensive care unit (ICU) stay. Results Compared with before ventilation, the levels of PaO2/FiO2, PaCO2, HR, R and Raw were significantly changed in two groups after ventilation (P<0.05). One day later after ventilation, pH [interventionvs. control: (7.43±0.07) vs. (7.37±0.11)], PaO2/FiO2[(253.52±65.33) mm Hg (1 mm Hg=0.133 kPa) vs. (215.46±58.72) mm Hg] and PaCO2 [(52.45±7.15) mm Hg vs. (59.39±8.44) mm Hg] were statistically significant (P<0.05), but no significant difference was found in HR, R or Raw between two groups (P>0.05). Compared with the control group, PIC [(3.7±1.4) daysvs. (5.3±2.2) days], IMV [(4.0±1.5) days vs. (6.1±3.0) days], MV [(4.7±2.0) days vs. (7.3±3.7) days] and ICU stay [(6.2±2.1) days vs. (8.5±4.2) days] were significantly decreased (P<0.05) in the intervention group. Conclusions In AECOPD patients, invasive ventilation using lateral position ventilation can significantly improve arterial blood gas index, decrease Raw, shorten the time of PIC, IMV, MV and ICU stay.
Objective To investigate the predictive value of mechanical power (MP) in the weaning outcome of adaptive mechanical ventilation plus intelligent trigger (AMV+IntelliCycle, simply called AMV) mode for acute respiratory distress syndrome (ARDS) patients. Methods From November 2019 to March 2021, patients with mild to moderate ARDS who were treated with invasive mechanical ventilation in the intensive care unit of the First Affiliated Hospital of Jinzhou Medical University were divided into successful weaning group and failed weaning group according to the outcome of weaning. All patients were treated with AMV mode during the trial. The MP, oral closure pressure (P0.1), respiratory rate (RR) and tidal volume (VT) of the two groups were compared 30 min and 2 h after spontaneous breathing trial (SBT). The correlation between 30 min and 2 h MP and shallow rapid respiratory index (RSBI) was analyzed by Pearson correlation. Receiver operating characteristic (ROC) curve was used to analyze the predictive value of 30 min MP in ARDS patients with AMV mode weaning failure. Results Sixty-eight patients were included in the study, 49 of them were successfully removed and 19 of them failed. There was no statistical significance in age, gender, body mass index, oxygenation index, acute physiology and chronic health evaluation Ⅱ score, reasons for mechanical ventilation (respiratory failure, sepsis, intracranial lesions, and others) between the two groups (all P>0.05). The MP, P0.1 and RR at SBT 30 min and 2 h of the successful weaning group was lower than those of the failed weaning group (all P<0.05), but the VT of the successful weaning group was higher than the failed weaning group (all P<0.05). There was a significant relation between the MP at SBT 30 min and 2 h and RSBI (r value was 0.640 and 0.702 respectively, both P<0.05). The area under ROC curve of MP was 0.674, 95% confidence interval was 0.531 - 0.817, P value was 0.027, sensitivity was 71.73%, specificity was 91.49%, positive predictive value was 0.789, negative predictive value was 0.878, optimal cutoff value was 16.500. The results showed that 30 min MP had a good predictive value for the failure of weaning in AMV mode in ARDS patients. Conclusion MP can be used as an accurate index to predict the outcome of weaning in ARDS patients with AMV mode.
Objective To evaluate the relationship between sublingual microcirculation differences and weaning success rate and prognosis in elderly patients with severe pneumonia. Methods A retrospective observation cohort study was conducted. Forty-two elderly patients with severe pneumonia who underwent mechanical ventilation in the intensive care unit of Sir Run Run Hospital, Nanjing Medical University from February 2022 to August 2022 were recruited in the study. They were divided into a high-flow nasal cannula oxygen group (HFNC group, n=33) and a non-invasive positive pressure ventilation group (NIPPV group, n=9) according to the mode of post-weaning ventilation. The differences of N-terminal brain natriuretic peptide precursor (NT-proBNP), cardiac index (CI) and sublingual microcirculation indexes between the two groups were analyzed. The receiver operating characteristic (ROC) curve was used to analyze the predictive value of each parameter on weaning success rate and case fatality rate. Results Compared with the NIPPV group, CI, propotion of perfused vessels (PPV) and perfused vessel density (PVD) were higher, and NT-proBNP and total vessel density (TVD) were lower in the HFNC group (all P<0.05). The prediction value of PPV combined with PVD was the largest, with area under the ROC curve (AUC) of 0.875, sensitivity of 75.8%, specificity of 88.9%. CI, NT-proBNP, CI combined with NT-proBNP, PPV, PVD all had predictive value. Compared with the death group, the survival group had higher CI, central venous-to-arterial carbon dioxide difference [P(v-a)CO2] and PPV. For the prediction value of weaning success, CI combined with NT-proBNP had the largest predictive value, with AUC of 0.919, sensitivity of 81.8%, specificity of 100.0%, followed by CI. NT-proBNP, PPV, PVD, PPV combined with PVD all had predictive value. Compared with the death group, the survival group had higher CI, P(v-a)CO2 and PPV (all P<0.05). For predictive value assessment of 28-day survival rate, CI plus PPV had the largest AUC of 0.875, with sensitivity of 69.4%, and specificity of 100.0%. CI, P(v-a)CO2 and PPV all have predictive value. Conclusions Both CI and PPV can be used as predictors of weaning success rate and survival rate. PPV combined with PVD is an ideal predictor of survival rate.