west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "wire" 53 results
  • Clinical analysis of CT-guided preoperative Hookwire localization of pulmonary nodules in 102 patients

    ObjectiveTo study the feasibility and safety of CT-guided preoperative Hookwire localization of pulmonary nodules in clinical application.MethodsClinical data of 102 patients who were scheduled to undergo surgical treatment for pulmonary nodules from June 2015 to April 2020 in the North Ward of Thoracic Surgery Department of Ruijin Hospital were retrospectively analyzed. There were 38 males and 64 females, aged 23-82 (53.2±12.8) years.ResultsAll 102 patients with pulmonary nodules underwent CT-guided preoperative Hookwire localization successfully, with a localization success rate of 100.0%. The localization time was 27.0 (11-67) min; the number of times to adjust the angle during the positioning process was 6.9 (3-14); the needle depth of the positioning needle was 41.5 (16.3-69.1) mm. A total of 48 (47.1%) patients had a small amount of bleeding in the lung tissue in the positioning area after positioning; 53 (51.9%) patients had a small amount of pneumothorax after positioning; 16 (15.7%) patients were found that the positioning needle completely shedded from the lung tissue in the subsequent surgery. One patient was transferred to open thoracotomy because of extensive dense adhesion in the thorax, and the remaining 101 patients were operated on under thoracoscopy. Postoperative pathology showed that 5 (4.9%) patients were adenocarcinoma in situ, 28 (27.5%) were microinvasive adenocarcinoma, 36 (35.3%) patients were invasive carcinoma and 32 (31.3%) patients were benign lesions. No patients had complications or adverse events related to preoperative positioning.ConclusionPreoperative CT-guided localization of Hookwire intrapulmonary nodules is safe and effective, and can meet the intraoperative localization needs of thoracic surgeons in most clinical situations, and is not inferior to other preoperative localization methods currently used in clinics.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • CT-guided Hook-wire versus microcoil localization in the pulmonary nodules surgery: A systematic review and meta-analysis

    ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.

    Release date:2023-06-13 11:24 Export PDF Favorites Scan
  • Application of 3D reconstruction and Hookwire to localize pulmonary nodules in thoracoscopic pulmonary segmentectomy

    ObjectiveTo investigate the clinical value of 3D CT combined with CT-guided Hookwire for localizing small pulmonary nodules in thoracoscopic pulmonary segmentectomy.MethodsFrom December 2017 to February 2019, 39 patients received thoracoscopic pulmonary segmentectomy in our hospital, including 14 males and 25 females with a mean age of 51.33±11.17 years. Before operation, we used Mimics Medical 20.0 to re-establish the anatomy of lung and locate the small pulmonary nodules with Hookwire guided by CT. Based on the position of Hookwire needle, 3D CT images and simulated surgical methods, thoracoscopic pulmonary segmentectomy was performed accurately.ResultsThe surgery was successfully completed in 39 patients without a transfer to open procedure. The mean operation time, mean intraoperative blood loss, mean postoperative hospital stay, mean thoracic tube drainage time were 148.97±28.56 min, 27.95±17.57 mL, 6.95±1.68 d, 4.21±1.95 d, respectively. Postoperative complications occurred in 5 patients (12.82%), including atrial fibrillation in 1, pulmonary infection in 1, chylothorax in 1, intrathoracic hemorrhage in 1 and pneumothorax in 1. All actual surgical margins were larger than 3.0 cm.ConclusionThe application of preoperative 3D CT combined with CT-guided Hookwire to localize small pulmonary nodules is helpful for accurate anatomical segmental resection of the lung, making the operation safe .

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • Arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation

    ObjectiveTo explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation. MethodsThe clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation. ResultsAll patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation (t=12.851, P<0.001; t=−14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair. Conclusion Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Design and preliminary validation of a ubiquitous and wearable physiological monitoring system

    To achieve continuously physiological monitoring on hospital inpatients, a ubiquitous and wearable physiological monitoring system SensEcho was developed. The whole system consists of three parts: a wearable physiological monitoring unit, a wireless network and communication unit and a central monitoring system. The wearable physiological monitoring unit is an elastic shirt with respiratory inductive plethysmography sensor and textile electrocardiogram (ECG) electrodes embedded in, to collect physiological signals of ECG, respiration and posture/activity continuously and ubiquitously. The wireless network and communication unit is based on WiFi networking technology to transmit data from each physiological monitoring unit to the central monitoring system. A protocol of multiple data re-transmission and data integrity verification was implemented to reduce packet dropouts during the wireless communication. The central monitoring system displays data collected by the wearable system from each inpatient and monitors the status of each patient. An architecture of data server and algorithm server was established, supporting further data mining and analysis for big medical data. The performance of the whole system was validated. Three kinds of tests were conducted: validation of physiological monitoring algorithms, reliability of the monitoring system on volunteers, and reliability of data transmission. The results show that the whole system can achieve good performance in both physiological monitoring and wireless data transmission. The application of this system in clinical settings has the potential to establish a new model for individualized hospital inpatients monitoring, and provide more precision medicine to the patients with information derived from the continuously collected physiological parameters.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Mid-term effectiveness of cerclage wires fixation in treatment of periprosthetic femoral fractures associated with primary hip arthroplasty

    Objective To evaluate the mid-term effectiveness of cerclage wires fixation in treating Mallory typeⅡperiprosthetic femoral fractures associated with primary hip arthroplasty. Methods A retrospective analysis was made in the data of 14 patients (14 hips) with Mallory typeⅡ periprosthetic femoral fractures associated with primary hip arthroplasty and treated with cerclage wires fixation between January 2010 and June 2011 (fracture group). Twenty-eight patients (28 hips) without periprosthetic femoral fractures associated with primary hip arthroplasty at the same stage were chosen as control group. The uncemented femoral prosthesis were used in 2 groups. There was no significant difference in gender, age, body mass index, and primary disease between 2 groups (P>0.05). The operation time, intraoperative blood loss, and the complications were recorded. The Harris score was used to evaluate the hip function and the visual analogue scale (VAS) score was used to evaluate the pain degree of hip. According to the postoperative X-ray films of hips, Enghet al. standard was used to evaluate the fixed and stable status of the femoral prosthesis; the heterotopic ossification was observed; the time of fracture union was recorded. Results The operation time of fracture group was significantly longer than that of control group (t=–3.590, P=0.001). There was no significant difference in the intraoperative blood loss between 2 groups (t=–1.276, P=0.209). All patients were followed up 64-75 months (mean, 69.5 months). Hip dislocation after operation occurred in 1 case of fracture group; delirium symptom and nonunion of incision occurred in 1 case and 1 case of control group, respectively. There was no significant difference in the Harris score and VAS score at 6 months and 5 years between 2 groups (P>0.05). X-ray films showed that all fractures healed and the mean time of fracture union were 6.1 months (range, 3-12 months). There was no fracture nonunion or malunion evidently. There was no significant difference in X-ray score at 6 months and 5 years between 2 groups (P>0.05). At last follow-up, cerclage wires displacement or breakage did not occur. Heterotopic ossification occurred in 2 cases of fracture group and in 1 case of control group. Conclusion Cerclage wires fixation can achieve the good mid-term effectiveness in treating Mallory typeⅡintraoprative periprosthetic femoral fractures associated with primary hip arthroplasty.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Hookwire术前定位在胸腔镜下肺部孤立性小结节切除术中的应用

    目的总结hookwire术前定位在全胸腔镜下切除肺部直径小于2 cm的孤立性小结节的临床经验。 方法回顾性分析2010年7月至2012年10月中山大学附属中山医院82例肺部孤立性小结节,共88个直径小于2 cm的肺部孤立性病灶,行全胸腔镜下病灶切除术,术前均在数字减影(DSA)Innova CT引导下采用hookwire对病灶穿刺定位的临床资料,其中男47例、女35例,年龄34~78(61.4±10.7)岁。对手指触诊阳性率与病灶临床因素进行相关性分析,比较手指触诊与hookwire定位的成功率,并总结hookwire定位的安全性、有效性及适应证。 结果Hookwire定位常见并发症为无症状气胸13例(14.8%),少量血胸7例(7.9%),严重胸痛3例(3.4%)。9个病灶(10.2%)术中发现穿刺针移位。85个(96.5%)病灶可通过Hookwire准确定位,与触诊(53.4%)准确性差异无统计学意义(P=0.097)。手指触诊的阳性率与病灶的病理类型和病灶的性质有关,对于微浸润性/浸润前病变、肺部单纯性磨玻璃样结节(pure ground-glass opacity,pGGO)的触诊阳性率明显偏低,分别为25.8%和19.2%。 结论对于直径小于2 cm的肺部孤立性结节,胸腔镜手术前hookwire穿刺定位是一项安全的技术。其最佳适应证为直径小于2 cm的pGGO。

    Release date: Export PDF Favorites Scan
  • CLINICAL STUDIES ON MAINTENANCE OF CROSS-LEG POSITION THROUGH INTERNAL FIXATION WITH KIRSCHNER WIRE AFTER CROSSLEG FLAP PROCEDURE

    Objective To study the feasibility of a new method for the cross-leg position maintained by the Kirschner wire internal fixation after the cross-leg flap procedure. Methods From December 2004 to October 2005, 5 patients (4 males, 1 female; aged 14-52 years) were admitted to our department, who suffered from the tibia exposure or the internal fixation plate exposure after operation because of the tibia fracture by trauma for 1-8 weeks. The soft tissue defects ranged in area from 2.4 cm × 2.0 cm to 4.2 cm × 3.0 cm. The soft tissue around the wound in the leg was too poor in condition to perform an operation of the local flap transplantation, but the wound and the tibia had no obvious infection, so an operation of the cross-leg flap transplantation was performed to cover the wounds. The operation was performed with the routine crossleg flap method introduced in the medical literature. After operation the cross-leg position was maintained through a simple internal fixation with two Kirschner wire, which were inserted through the tibia of the cross region of both thelegs, and layers of dressings were placed as a cushion between the crossed legsin case of the crushing skin ulcer formation. The effect of fixation, blood circulation in the cutaneous flap, and the stress of the pedicle were observed postoperatively. After 3-4 weeks the pedicle of the cross-leg flap was cut off; the crossed legs were detached and the Kirschner wire were pulled out. Results All the flaps survived with a good blood circulation and a low pedicle stress. The patients had a relatively comfortable position because all the areas of the legs could be allowed to make some motions except the cross-area ofthe legs. Another advantage of this fixation method was its convenience for observing the blood circulation of the cutaneous flap and for changing the dressings. Neither infection in the holes of the Kirschner wire nor crushing skin ulcer formation in the area of the cross-leg could be observed. The follow-up for 3-18 months revealed that all the flaps were in good condition with no edema, contracture or skin pigmentation. Conclusion The method of usingthe Kirschner wire to maintain the cross-leg position after the crossleg flapprocedure has more advantages than the plaster fixation. This improved method is simpler, and can achieve a tighter fixation in the crossleg area to maintainthe cross-leg position, allowing a micro-motion in other parts of the legs. The patients can have a relatively comfortable posture, and have a more convenient dressing changes and observation on the blood circulation in the flaps.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • Application of external fixator combined with Kirschner wire fixation for oblique and comminuted distal humeral metaphyseal-diaphyseal junction fractures in children

    ObjectiveTo analyze the effectiveness of external fixator combined with Kirschner wire (EF-KW) fixation in the treatment of oblique and comminuted distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children. Methods A clinical data of 22 children with DHMDJ fractures who met the selection criteria between April 2021 and December 2023 was retrospectively analyzed. All patients were treated with EF-KW fixation. There were 14 boys and 8 girls with an average age of 6.8 years (range, 1.5-12.0 years). The time from injury to operation was 14-38 hours (mean, 24.2 hours). There were 18 cases of comminuted fractures and 4 cases of oblique fractures; and 1 case of median nerve injury and 1 case of radial nerve injury before operation. The occurrence of postoperative complications was recorded. At last follow-up, the function of the affected elbow joint was evaluated according to the Mayo elbow joint function score, and the Baumann’s angle (BA) and humero-capitellar angle (HCA) of the affected and healthy sides were recorded and compared. ResultsAll fractures were successfully treated with closed reduction and no complications such as nerve injury occurred. Superficial infection occurred in 4 cases after operation and healed after symptomatic treatment. The incisions of other patients healed by first intention. All patients were followed up 9-24 months (mean, 13.8 months). At last follow-up, according to the Mayo elbow joint function score, the elbow joint function was rated as excellent in 15 cases, good in 6 cases, and fair in 1 case, with an excellent and good rate of 95.5%. The neurologic injury before operation recovered gradually. X-ray films reexamination showed that all fractures healed, and the healing time of fractures ranged from 29 to 61 days, with an average of 35.6 days. At last follow-up, there was no significant difference in BA and HCA between the healthy side and the affected side (P>0.05). During follow-up, 1 case developed mild cubitus varus, while the other patients had no serious complications. ConclusionEF-KW fixation for oblique and comminuted DHMDJ fractures in children has the advantages of less trauma, simple operation, easy reduction, good stability after reduction, low incidence of serious complications, and good elbow functional recovery.

    Release date:2024-07-12 11:13 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content