【Abstract】 Objective To investigate the qual itative rotation al ignment of components in total knee arthroplastyand the accuracy and the effectiveness of Bone Morphing computer assisted system when qual itatively practicing. MethodsFrom November 2002 to June 2003, 21 patients with three compartments osteoarthritis(21 knees) were treated by primarytotal knee arthroplasty after the conservative medical treatment failed, with the assistance of a “Bone Morphing” CeravisionSystem, implanted posterior stabil ized total knee prosthesis. Twenty-one patients included 5 males (5 knees) and 16 females (16knees) with an average age of 72.4 years (64-79 years) . The locations were left knee in 10 cases and right knee in 11 cases. Thepatients suffered from knee pain and l imitation of movement from 2 to 10 years. There were 14 genu varum and 7 genu valgumpreoperatively. The relative preoperative, intraoperative and postoperative data from cl inical check-up, the X-ray films and theintraoperative components rotational al ignment real-time records in CD Rom were analyzed. Results All operative incisionshealed up by first intension. Twenty-one patients were followed up 12-16 months(mean 13.3 months). For the achievement ofproper lower l imb al ignment and normal frontal laxity of knee, rotational al ignment of femoral components was from internalrotation (IR)1° to external rotation (ER) 5°, tibial components from IR 0° to ER 5°. In patients with genu varum, the rotationalal ignment of the femoral components was ER 1°- ER 5°, of tibial components ER 2°- ER 5°. In patients with genu valgum, the rotationalal ignment of femoral components was IR 1°- ER 4°, of tibial components IR 0°-ER 4°. After 3 months of operation, themean flexion angle measured as range of motion (ROM) was 115°(105-130°), the frontal laxsity measured as 0.2-0.5 cm (mean0.27 cm) of internal laxity and 1.0-2.5 cm (mean 1.7 cm) for external laxity, there were no knee pain, paterllar instabil ity or dislocationand abnormal knee frontal laxity. Conclusion Using Bone Morphing computer-assisted system can optimise theindividual components rotation al ignment accurately.
Objective To explore the effectiveness of computer-aided technology in the treatment of primary elbow osteoarthritis combined with stiffness under arthroscopy. Methods The clinical data of 32 patients with primary elbow osteoarthritis combined with stiffness between June 2018 and December 2020 were retrospectively analyzed. There were 22 males and 10 females with an average age of 53.4 years (range, 31-71 years). X-ray film and three-dimensional CT examinations showed osteophytes of varying degrees in the elbow joint. Loose bodies existed in 16 cases, and there were 7 cases combined with ulnar nerve entrapment syndrome. The median symptom duration was 2.5 years (range, 3 months to 22.5 years). The location of bone impingement from 0° extension to 140° flexion of the elbow joint was simulated by computer-aided technology before operation and a three-dimensional printed model was used to visualize the amount and scope of impinging osteophytes removal from the anterior and posterior elbow joint to accurately guide the operation. Meanwhile, the effect of elbow joint release and impinging osteophytes removal was examined visually under arthroscopy. The visual analogue scale (VAS) score, Mayo elbow performance score (MEPS), and elbow range of motion (extension, flexion, extension and flexion) were compared between before and after operation to evaluate elbow function. Results The mean operation time was 108 minutes (range, 50-160 minutes). All 32 patients were followed up 9-18 months with an average of 12.5 months. There was no other complication such as infection, nervous system injury, joint cavity effusion, and heterotopic ossification, except 2 cases with postoperative joint contracture at 3 weeks after operation due to the failure to persist in regular functional exercises. Loose bodies of elbow and impinging osteophytes were removed completely for all patients, and functional recovery was satisfactory. At last follow-up, VAS score, MEPS score, extension, flexion, flexion and extension range of motion significantly improved when compared with preoperative ones (P<0.05). Conclusion Arthroscopic treatment of primary elbow osteoarthritis combined with stiffness using computer-aided technology can significantly reduce pain, achieve satisfactory functional recovery and reliable effectiveness.
【Abstract】 Objective To investigate the appl ication and significance of computer assisted orthopedicsurgery(CAOS) in orthopedic trauma surgery. Methods In orthopedic trauma surgery, the appl ication status of CAOS was?analysed and the related problems were summarized. Results At present, CAOS is seldom used to reduce fractures but frequently used to insert internal fixation devices and reconstruct the cruciate l igament in orthopedic trauma surgery. And the studies have shown its superiority. During CAOS appl ication, surgeons should pay attention to some problems such as the disadvantages, cl inical evaluation, the roles of the surgeons and correct micro-traumatic concept. Conclusion CAOS is very important and cannot be replaced in orthopedic trauma minimal invasion surgery and surgeons should pay attention to some important related problems to make it develop successfully in the study of CAOS.
Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.
Objective To design a new custom-made artificial semi-knee joint based on rapid prototyping(RP) technique and to explore a method to solve necroses of allocartilage in hemi-joint allotransplantation. Methods Based on the extracted 3D contour image of the articular cartilage of femoral condyle, the custom-made artificial semi-knee joint was designed with Surfacer 9.0 image processingsoftware. The artificial semi-knee joint design used the femoral condylar 3D contour of the patient as the outer face and the subchondral bone 3D contour of allograft bone as inner face. One dado for medullary nailand two for special designing cages which were used to fix the cartilage into the allograft were added on the inner face. After being converted into RP data format, the computerassisted design was imported into the LPS600 rapid prototyping machine, and the prototype was achieved. Furthermore, the prototype could be modified by hand according to the design. Then the RP model was used as a positive mould to build up a silica gel negativemould, and the negative mould was sent to the factory to manufacture Ti-6Al-4V alloy articular cartilage through ordinary mould-melted founding process. Finally, the whole metal cartilage was completed after melting two special cages on it andpolishing it. Results A new custom-made artificial semi-knee joint was made ad used to treat a 14-year old patient. The custom-made artificial semi-knee joint and the subchondral bone were a perfect match. The operative result was satisfactory. The patient could walk 5 weeks after operation. The bone healing of the auto-bone and allo-bone was achieved 6 months later. A follow-up period lasting 1 yearshowed that the knee joint played a good function. Conclusion The artificial semi-knee joint is a good match for the allograft boneand a good idea to solve necroses of allocartilage in hemijoint allotransplantation.
Objective To explore the therapeutic effect of rehabilitation therapy combined with computer-aided design and computer-aided manufacture (CAD/CAM) of orthopedic insoles on deputy scaphoid inflammation. Methods We selected the patients with deputy scaphoid inflammation who had treated in Sichuan Province Orthopedic Hospital between July 2018 and February 2020. The patients were randomly divided into control group and experimental group by drawing lots. The control group received rehabilitation therapy, while the experimental group received rehabilitation therapy combined with CAD/CAM orthopedic insoles. The clinical efficacy was tested at the 5th and 12th weeks after treatment, and the foot pain was assessed by Visual Analogue Scoring (VAS), and the foot function was assessed by the American Orthopaedic Foot and Ankle Association (AOFAS) scale. Results A total of 78 patients were included, and 3 patients dropped out. There was no significant difference in sex, age, weight or course of disease between the two groups (P>0.05). Before treatment, there was no statistically significant difference in VAS score (t=0.329, P=0.743) or AOFAS score (t=0.431, P=0.668) between the two groups. At the 5th and 12th weeks after treatment, the VAS score of the experimental group was lower than that of the control group (t=4.517, 5.299; P<0.001), and the AOFAS score was higher than that of the control group (t=6.239, 5.779; P<0.001). Over time, the VAS score of the two groups decreased (P<0.05), while the AOFAS score increased (P<0.05). Conclusion Rehabilitation therapy combined with CAD/CAM of orthopedic insoles have better curative effect than traditional rehabilitation therapy for deputy scaphoid inflammation.
ObjectiveTo compare the application effects between personal specific instrumentation (PSI) and computer-assisted navigation surgery (CAS) in total knee arthroplasty (TKA). MethodsThe literature comparing the application effects of PSI and CAS in TKA in recent years was widely consulted, and the difference between PSI-TKA and CAS-TKA in operation time, lower limb alignment, blood loss, and knee function were compared. ResultsCompared to CAS-TKA, PSI-TKA simplifies operation procedures and shortens operation time but probably has worse lower limb alignment. It is still controversial in comparison of perioperative blood loss and knee function between two techniques. ConclusionPSI-TKA and CAS-TKA both have advantages and disadvantages, and their differences need to be confirmed by further high-quality clinical trial.
Objective To improve the accuracy of the acetabular component placement using the nonimage based surgical navigation system. Methods Twenty-three patients (14 males, 9 females; age, 28-55 years;26 hips)with hip disease underwent the total hip arthroplasty (THA) using the nonimage based surgicalnavigation system from February 2004 to April 2006. Rheumatoid arthritis was found in 3 patients (3 hips), necrosis of the femoral head in 6 patients (6 hips), and osteoarthritis in 14 patients (16 hips). All the patients were randomly divided into the following 2 groups: the navigated group (11 patients, 13 hips), treated by THA using the nonimage based surgical navigation system; and the control group (12 patients, 13 hips), treated by the traditional THA. According to thedesign of the study, the acetabular component was placed in the best inclination angle (45°) and the anteversion angle (15°). The postoperative component position was examined. Results No fracture, dislocation, infection or injury to the sciatic nerve was found. In the navigated group, the inclination and the anteversion reached 15.4±1.4° and 45.5±1.3°, respectively. In the control group,the inclination and the anteversion were 13.9±7.6° and 43.7±6.4°, respectively. The inclination difference was considered statistically significant (Plt;0.01). All the patients were followed up for 10-40 months,averaged 26 months. In the navigated group, the postoperative average Harris hip score was 95 (range,85-110), with an excellent result in 11 hips and a good result in 2 hips. In the control group, the postoperative average Harris hip score was 92 (range,75-110), with an excellent result in 9 hips, a good result in 3 hips, and a fair result in 1 hip. The Harris hip score difference was considered statistically significant (Plt;0.05). There was a significantly better result obtained in the navigated group than in the control group. Conclusion The acetabular component can be implanted accurately by the nonimage based surgical navigation system, which can reduce the incidence of the loosening of the prostheses and has an important value in clinical practice.
Objective To evaluate the security and effectiveness of minimal invasive fixation with fluoroscopybased navigation in the management of pelvic fractures. Methods From April 2007 to June 2008, 22 patients with pelvic fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system after closed reduction. There were 13 males and 9 females, aged 21-65 years old. Fractures were caused by traffic accident in 17 cases, andfall ing from height in 5 cases. According to AO classification, there were 2 cases of A2.2 type, 2 cases of A2.3 type, 7 cases of B1.2 type, 3 cases of B2.2 type, 1 case of B3.3 type, 2 cases of C1.2 type, 3 cases of C1.3 type, and 2 cases of C2.3 type. The interval from injury to hospital ization was 4 hours to 3 days (mean 1.2 days). After 3-13 days of skeletal traction through tibial tubercle, the operation was performed. Results Totally 42 screws were inserted. The average time for operation was 20.4 minutes per screw. Forty-one screws were inserted correctly with a successful insertion rate of 97.6%, only 1 hollow screw was reinserted for deviation. No incision problem and implant failure occurred. All 22 patients were followed up 7 to 21 months with an average of 14.5 months. At last follow-up, fracture union was achieved in all patients with satisfactory screw fixation. According to Majeed functional scoring, the results were excellent in 18 cases and good in 4 cases, with an excellent and good rate of 100%. Conclusion The minimal invasive fixation with fluoroscopy-based navigation makes the surgery for the pelvic fracture more precise and time-saving, and improves cl inical results without an increasing rate of compl ications.
ObjectiveTo systematically evaluate the efficacy and safety of computer-aided detection (CADe) and conventional colonoscopy in identifying colorectal adenomas and polyps. MethodsThe PubMed, Embase, Cochrane Library, Web of Science, WanFang Data, VIP, and CNKI databases were electronically searched to collect randomized controlled trials (RCTs) comparing the effectiveness and safety of CADe assisted colonoscopy and conventional colonoscopy in detecting colorectal tumors from 2014 to April 2023. Two reviewers independently screened the literature, extracted data, and evaluated the risk of bias of the included literature. Meta-analysis was performed by RevMan 5.3 software. ResultsA total of 9 RCTs were included, with a total of 6 393 patients. Compared with conventional colonoscopy, the CADe system significantly improved the adenoma detection rate (ADR) (RR=1.22, 95%CI 1.10 to 1.35, P<0.01) and polyp detection rate (PDR) (RR=1.19, 95%CI 1.04 to 1.36, P=0.01). It also reduced the missed diagnosis rate (AMR) of adenomas (RR=0.48, 95%CI 0.34 to 0.67, P<0.01) and the missed diagnosis rate (PMR) of polyps (RR=0.39, 95%CI 0.25 to 0.59, P<0.01). The PDR of proximal polyps significantly increased, while the PDR of ≤5 mm polyps slightly increased, but the PDR of >10mm and pedunculated polyps significantly decreased. The AMR of the cecum, transverse colon, descending colon, and sigmoid colon was significantly reduced. There was no statistically significant difference in the withdrawal time between the two groups. Conclusion The CADe system can increase the detection rate of adenomas and polyps, and reduce the missed diagnosis rate. The detection rate of polyps is related to their location, size, and shape, while the missed diagnosis rate of adenomas is related to their location.