find Keyword "Autologous blood" 3 results
  • Application of Acute Non-isovolemic Hemodilution for Spinal Surgery

    ObjectiveTo investigate the effect of acute non-isovolemic hemodilution (ANIH) on spinal surgery. MethodsFrom January 2012 to July 2013, 80 patients scheduled for spinal surgery were enrolled. The patients were randomized into four groups, with 20 in each group. Patients in group A were infused with Ringer's injection and polygeline for fluid loss, physiological needs and blood loss. In group B, the patients were infused with acute hypervolemic hemodilution. In group C, patients were infused with acute nomovolemic hemodilution. In group D, patients were infused with ANIH. The hemodynamics and arterial blood gas indexes were detected in all the patients. ResultsThe mean blood pressure in group A and C was significantly more stable than that in group B and D. The central vein pressure in group B and D was significantly higher than that in group A and C after hemodilution (P<0.05), while the hematocrit in group B and D was significantly lower than that in group A and C (P<0.05). Allogeneic blood transfusion was performed in group A and B, while it was not performed in group C and D. ConclusionANIH can reduce the volume of blood loss during spinal surgery, and it is safe.

    Release date: Export PDF Favorites Scan
  • Effect of Acute Normovolemic Hemodilution with Autologous Blood Transfusion and Controlled Hypotension during Surgery on Allogeneic Blood Transfusion and Blood Coagulation Function

    ObjectiveTo observe the effect of acute normovolemic hemodilution (ANH) with autologous blood transfusion (ABT) and controlled hypotension (CH) during surgery on allogeneic blood transfusion and blood coagulation function. MethodsSixty patients in our hospital from February 2012 to January 2014 were chosen as our study subjects. They underwent surgeries of grade Ⅲ to Ⅳ, and the estimated amount of bleeding during surgery was more than 400 mL. The patients were randomized into group A (ANH+CH group) and group B (control group), with 30 in each. Patients in group A were first administered a standard endotracheal general anesthesia. Then an invasive arterial blood pressure monitoring was performed and the central venous blood was taken. ANH was implemented, and CH was applied to reduce bleeding. When the procedure was almost completed, ABT was implemented. The value of hematocrit, hemoglobin, platelet, prothrombin time (PT), activated partial thranboplastin time (APTT), fibrinogen, international normalized ratio (INR), heart rate, mean arterial pressure and central venous pressure were measured and recorded at the end of blood volume collection (T1), and before ABT (T2) and after ABT (T3). When hemoglobin was lower than 70 g/L during the surgery, ABT was implemented. After surgery, no allogeneic blood transfusion was performed if hemoglobin was higher than 90 g/L. Patients in group B received routine treatment. ResultsPatients' hemodynamics maintained relatively stable during ANH+ABT+CH. Blood volume collected from patients was (408.3 ±142.1) mL; blood loss volume was (705.4±586.8) mL. Compared with group B, the amount of bleeding was significantly lower, and it was reduced by (549.2±250.2) mL. No organ damage was found. For group A, compared with those values at T0, PT, hematocrit, hemoglobin, fibrinogen, and INR were significantly different at T1 and T2 (P<0.05), but the average value was within the acceptable range which did not affect the blood coagulation function. PT, APTT, platelet, hematocrit, hemoglobin, fibrinogen, and INR were significantly different before and after autologous blood transfusion (P<0.05). Postoperative infection and non-healing wounds rate was not significantly different between the two groups (P>0.05). ConclusionThis technique of acute normovolemic hemodilution with autologous blood transfusion and controlled hypotension is a useful, efficient and cost-effective blood conservation strategy. Moderate hemodilution has no influence on blood coagulation function in patients.

    Release date: Export PDF Favorites Scan
  • Research progress on autologous blood patch pleurodesis

    Autologous blood patch pleurodesis (ABPP) was first proposed in 1987. Now it is mainly used to treat intractable pneumothorax and persistent pneumothorax after pneumonectomy, and also used to treat pneumothorax in children and other rare secondary pneumothorax. Persistent air leakage and pneumothorax of various causes are essentially alveolar pleural fistula. It can usually be treated by closed thoracic drainage, continuous negative pressure suction and surgery. Pleurodesis is a safe and effective alternative to surgery for patients who have failed conventional conservative treatment and can not be operated. Compared with other pleurodesis adhesives, using autologous blood (ABPP) is safer and more effective, and it is simple, painless, cheap and easy to be accepted by patients. But in the domestic and foreign researches in recent years, many details of ABPP treatment have not been standardized. For further research and popularization, this article reviews the detailed regulations, efficacy and safety of ABPP.