In order to explore the application of the dielectric properties of white matter and grey matter in β, δ and γ dispersion transition zones used in clinical medicine and microwave imaging technology, we calculated the dielectric constant and its increment by using Cole-Cole equation. Based on the mutation of the increment of dielectric constant, the frequency range of three dispersions were evaluated. The dominate dispersion and the corresponding polarization mechanism were analyzed by using Cole-Cole circle. The results showed that there are 3 transition zones in brain white matter, which occur between β and δ dispersion, δ and γ dispersion and β and γ dispersion respectively. In grey matter, there are only 2 transition zones, which are between β and δ dispersion and δ and γ dispersion respectively. By comparing the frequency range of white matter and grey matter, the frequency range in white matter is broader than that in grey matter for the transition zone of β and δ dispersion with the β dispersion occupying dominate position in both tissues, and the corresponding polarization mechanism is interfacial polarization. For the transition zone of δ and γ dispersion, the frequency range in white matter is also broader than that in grey matter with the δ dispersion occupying dominate position in both tissues, and the corresponding polarization mechanism is orientation polarization. This study can provide basic theory and reference for diagnosis of brain diseases and microwave imaging technology.
Cholangiocarcinoma is a highly malignant tumor. It is not sensitive to radiotherapy and chemotherapy and has a poor prognosis. At present, there is no effective treatment. As a new method for treating cancer, magnetic fluid hyperthermia has been clinically applied to a variety of cancers in recent years. This article introduces it to the cholangiocarcinoma model and systematically studies the effect of magnetic fluid hyperthermia on cholangiocarcinoma. Starting from the theory of magnetic fluid heating, the electromagnetic and heat transfer models were constructed in the finite element simulation software COMSOL using the Pennes biological heat transfer equation. The Helmholtz coil was used as an alternating magnetic field generating device. The relationship between the magnetic fluid-related properties and the heating power was analyzed according to Rosensweig’s theory. After the multiphysics coupling simulation was performed, the electromagnetic field and thermal field distribution in the hyperthermia region were obtained. The results showed that the magnetic field distribution in the treatment area was uniform, and the thermal field distribution met the requirements of hyperthermia. After the magnetic fluid injection, the cholangiocarcinoma tissue warmed up rapidly, and the temperature of tumor tissues could reach above 42 °C, but the surrounding healthy tissues did not heat up significantly. At the same time, it was verified that the large blood vessels around the bile duct, the overflow of the magnetic fluid, and the eddy current heat had little effect on thermotherapy. The results of this article can provide a reference for the clinical application of magnetic fluid hyperthermia for cholangiocarcinoma.
Currently, transcranial magnetic stimulation (TMS) has been widely used in the treatment of depression, Parkinson’s disease and other neurological diseases. To be able to monitor the brain’s internal activity during TMS in real time and achieve better treatment outcomes, the researchers proposed combining TMS with neuroimaging methods such as magnetic resonance imaging (MRI), both of which use Tesla-level magnetic fields. However, the combination of strong current, large magnetic field and small size is likely to bring physical concerns which can lead to mechanical and thermal instability. In this paper, the MRI static magnetic field, the TMS coil and human head model were built according to the actual situations. Through the coupling of the magnetic field and the heat transfer module in the finite element simulation software COMSOL, the force and temperature of the TMS coil and head were obtained when the TMS was used in combination with MRI (TMS-MRI technology). The results showed that in a 3 T MRI environment, the maximum force density on the coil could reach 2.51 × 109 N/m3. Both the direction of the external magnetic field and the current direction in the coil affected the force distributions. The closer to the boundary of the external magnetic field, the greater the force. The magnetic field generated by the coil during TMS treatment increased the temperature of the brain tissue by about 0.16 °C, and the presence of the MRI static magnetic field did not cause additional thermal effects. The results of this paper can provide a reference for the development of the use guidelines and safety guidelines of TMS-MRI technology.
In this paper, we established magnetic fluid hyperthermia (MFH) model for rat tumor using the finite element software COMSOL based on the linear response theory. By analyzing four kinds of magnetic medium within relaxation mechanism, such as Fe3O4、FeCo、fccFePt and L10FePt, we studied the influence of the change of magnetic medium radius on dissipation power and temperature field, respectively. At the same time, the optimization method for the parameters of several magnetic medium is proposed, and the applications of four kinds of magnetic medium are given as well. By increasing the dissipation power of the magnetic medium as much as possible, the dose of magnetic medium used in the treatment can be reduced, meanwhile, the adverse effects on health tissue surrounding the tumor will be minimized. The conclusions of this paper can provide reference for magnetic medium preparation applied to MFH.