ObjectiveTo clarify the value of the cortical endo-button as an internal fixator in Latarjet procedure through biomechanical analysis.MethodsTen pairs of shoulder joints from 6-7 months old male pigs were selected. Each pair was randomly divided into screw group and endo-button group. A 25% glenoid defect model was created, and the porcine infraspinatus tendon and its associated bone were used to simulate conjoint tendon and coracoid process in human body. The bone grafts were fixed with two 3.5 mm screws and double cortical endo-buttons with high-strength sutures in screw group and endo-button group, respectively. The prepared glenoid defect model was fixed on a biomechanical test bench and optical markers were fixed on the glenoid and the bone block, respectively. Then fatigue test was performed to observe whether the graft or internal fixator would failed. During the test, the standard deviations of the relative displacement between the graft and the glenoid of two groups were measured by optical motion measure system for comparison. Finally the maximum failure load comparison was conducted and the maximum failure loads of the two groups were measured and compared.ResultsThere was no tendon tear, bone fracture, and other graft or internal fixation failure in the two groups during the fatigue test. The standard deviation of the relative displacement of the screw group was (0.007 87±0.001 44) mm, and that of the endo-button group was (0.034 88±0.011 10) mm, showing significant difference between the two groups (t=7.682, P=0.000). The maximum failure load was (265±39) N in screw group and (275±52) N in endo-button group, showing no significant difference between the two groups (t=1.386, P=0.199). There were 3 ways of failure: rupture at bone graft’s tunnel (6/10 from screw group, 3/10 from endo-button group), tendon tear at the cramp (2/10 from screw group, 2/10 from endo-button group), and tendon tear at the internal fixator interface (2/10 from screw group, 5/10 from endo-button group), showing no significant difference between the two groups (P=0.395).ConclusionAlthough the endo-button fixation fails to achieve the same strong fixation stability as the screw fixation, its fixation stability can achieve the clinical requirements. The two fixation methods can provide similar fixation strength when being used in Latarjet procedure.
Objective To evaluate the short-term effectiveness of modified arthroscopic Latarjet procedure with double EndoButtons for recurrent anterior shoulder dislocation. Methods Between January 2019 and November 2020, 36 patients with recurrent anterior shoulder dislocation were treated by modified arthroscopic Latarjet procedure with double EndoButtons. There were 26 males and 10 females, with an average age of 27.8 years (range, 18-36 years). The number of shoulder dislocations ranged from 3 to 12 times, with an average of 6.5 times. The disease duration ranged from 5 to 36 months, with an average of 16.2 months. Preoperative shoulder fear test was positive, and the Beighton score of joint relaxation was 0-4, with an average of 1.3. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 16%-28%, with an average of 21.5%. Postoperative complications, recurrent dislocation, subluxation, and instability of shoulder joint were recorded. Shoulder range of motion was examined, including forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery Score (ASES), and ROWE score. X-ray film and CT images were taken to observe the shaping of coracoid process graft. Results All incisions healed by first intention, and no vascular or nerve injury occurred. All patients were followed up 12-28 months, with an average of 19.9 months. During follow-up, no shoulder dislocation recurred, and shoulder fear test was negative. At last follow-up, there was no significant difference in shoulder forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation when compared with preoperative values (P>0.05). The Walch-Duplay score, ASES score, and ROWE score of shoulder function significantly improved (P<0.05). Postoperative imaging examination showed that coracoid process graft was at the same level with the glenoid in 33 cases (91.7%), medial in 1 case (2.8%), and lateral in 2 cases (5.6%); the center of coracoid process graft was mainly located between 3 to 5 o’clock in 33 cases (91.7%), higher than 3 o’clock in 1 case (2.8%), and lower than 5 o’clock in 2 cases (5.6%). There was no obvious glenohumeral joint degeneration during follow-up, and the coracoid process graft gradually formed concentric circles with the humeral head. Conclusion The modified arthroscopic Latarjet procedure with double EndoButtons can effectively treat recurrent anterior shoulder dislocation, and the short-term effectiveness is satisfactory, and the position of coracoid process graft is accurate.
ObjectiveTo review the research progress of the biomechanical study of the Bristow-Latarjet procedure for anterior shoulder dislocation. MethodsThe related biomechanical literature of Bristow-Latarjet procedure for anterior shoulder dislocation was extensively reviewed and summarized. ResultsThe current literature suggests that when performing Bristow-Latarjet procedure, care should be taken to fix the bone block edge flush with the glenoid in the sagittal plane in the direction where the rupture of the joint capsule occurs. If traditional screw fixation is used, a double-cortical screw fixation should be applied, while details such as screw material have less influence on the biomechanical characteristics. Cortical button fixation is slightly inferior to screws in terms of biomechanical performance. The most frequent site of postoperative bone resorption is the proximal-medial part of the bone block, and the cause of bone resorption at this site may be related to the stress shielding caused by the screw. ConclusionThere is no detailed standardized guidance for bone block fixation. The optimal clinical treatment plan for different degrees of injury, the factors influencing postoperative bone healing and remodeling, and the postoperative osteoarticular surface pressure still need to be further clarified by high-quality biomechanical studies.
Objective To review the research progress of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation, and provide a guide for further research on bone graft resorption. Methods The relevant literature in recent years was extensively reviewed. The pathogenesis, classification, risk factors, clinical function impact, and management of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation were summarized. Results Bone graft resorption is the common complication after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation. Stress shielding and poor blood supply may contribute to the occurrence of bone graft resorption. The absence of significant preoperative glenoid bone loss, open procedure, earlier graft healing may to be the risk factors for bone graft resorption. Various assessment methods and classification systems are used to evaluate the region and severity of bone graft resorption. Partial resorption may be considered as a natural glenoid remodeling process after the surgery, but severe and complete resorption is proved to be one of the reasons for failed procedures and there is no effective measure to prevent it, except for accepting revision surgery. Conclusion The pathogenesis, risk factors, clinical function impact of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation has not been fully elucidated and there is a lack of effective management strategies, so further clinical and basic researches are needed.
Objective To testify the spatial relationship between the subscapularis muscle splitting window and the axillary nerve in modified arthroscopic Latarjet procedure, which could provide anatomical basis for the modification of the subscapularis muscle splitting. MethodsA total of 29 adult cadaveric shoulder specimens were dissected layer by layer, and the axillary nerve was finally confirmed to walk on the front surface of the subscapularis muscle. Keeping the shoulder joint in a neutral position, the Kirschner wire was passed through the subscapularis muscle from back to front at the 4 : 00 position of the right glenoid circle (7 : 00 position of the left glenoid circle), and the anterior exit point (point A, the point of splitting subscapularis muscle during Latarjet procedure) was recorded. The vertical and horizontal distances between point A and the axillary nerve were measured respectively. Results In the neutral position of the shoulder joint, the distance between the point A and the axillary nerve was 27.37 (19.80, 34.55) mm in the horizontal plane and 16.67 (12.85, 20.35) mm in the vertical plane. Conclusion In the neutral position of the shoulder joint, the possibility of axillary nerve injury will be relatively reduced when radiofrequency is taken from the 4 : 00 position of the right glenoid (7 : 00 position of the left glenoid circle), passing through the subscapularis muscle posteriorly and anteriorly and splitting outward.
Objective To investigate the effectiveness of arthroscopic autologous iliac bone grafting with double-row elastic fixation in treatment of recurrent anterior shoulder dislocation combined with massive glenoid bone defects. Methods Between January 2018 and December 2021, 16 male patients with recurrent anterior shoulder dislocation combined with massive glenoid bone defects were treated with arthroscopic autogenous iliac bone grafting and double-row elastic fixation. The patients were 14-29 years old at the time of the first dislocation, with an average age of 18.4 years. The causes of the first dislocation included falling injury in 5 cases and sports injury in 11 cases. The shoulders dislocated 4-15 times, with an average of 8.3 times. The patients were 17-37 years old at the time of admission, with an average age of 25.1 years. There were 5 left shoulders and 11 right shoulders. The preoperative instability severity index (ISIS) score of the shoulder joint was 5.8±2.1, and the Beighton score was 4.3±2.6. The University of California Los Angeles (UCLA) score, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and Rowe score were used to evaluate shoulder function, and the degree of the glenoid bone defect repair was observed based on CT after operation. Results All incisions healed by first intention, and no complication such as incision infection or neurovascular injury occurred. The patients were followed up 12 months. At 12 months after operation, UCLA score, Constant score, ASES score, and Rowe score all significantly improved when compared with the scores before operation (P<0.05). CT imaging showed the degree of glenoid bone defect was significantly smaller at immediate, 6 and 12 months after operation when compared with that before operation (P<0.05), and the bone blocks healed with the scapula, and bone fusion had occurred at 12 months. ConclusionArthroscopic autologous iliac bone grafting with double-row elastic fixation is a safe treatment for recurrent anterior shoulder dislocation combined with massive glenoid bone defects, with good short-term effectiveness.
Objective To review the development and research progress of suture button fixation Latarjet procedure. Methods A comprehensive literature review was conducted to summarize the development and related modified techniques of the suture button fixation Latarjet procedure. Results Since the Latarjet procedure was first introduced by French scholar Latarjet in 1954, it has undergone three key transformations, resulting in suture button fixation Latarjet procedure, which has shown satisfactory outcomes in treatment of recurrent shoulder dislocation. However, there are still drawbacks such as the risk of impingement of the graft on surrounding tissues, and the surgical disruption of anatomical structures like the coracoclavicular ligament and the pectoralis minor muscle. The scholars have proposed several modified techniques based on the suture button fixation Latarjet procedure to further reduce complications from impingement of the graft, to lower the glenohumeral contact pressure, and to eliminate the impact of surgery on the physiological structures of the shoulder joint. The modified techniques include the arthroscopic suture button fixation Latarjet procedure using FiberTape Cerclage, reconstruction of the coracoacromial ligament during congruent-arc Latarjet procedures, and limit unique coracoid osteotomy suture button Latarjet procedure (LU-tarjet procedure). These modified techniques have also shown good clinical outcomes. Additionally, other related modified techniques for reconstruction of the glenoid, such as Chinese unique Inlay Bristow procedure (Cuistow procedure), arthroscopic glenoid bone grafting with soft fixation, and all-arthroscopic modified Eden-Hybinette procedure, have also demonstrated favorable efficacy. However, there is still a lack of long-term follow-up results for these techniques and comparative studies between them. Conclusion Suture button fixation Latarjet procedure is an effective method for the treatment of recurrent shoulder dislocation. There are various techniques, but there is no recognized gold standard, and further clinical and basic research is needed.
Objective To investigate the effectiveness of double EndoButton suture fixation Latarjet procedure in the treatment of shoulder anterior dislocation with glenoid bone defect caused by military training injuries.MethodsThe clinical data of 14 patients with anterior shoulder dislocation with glenoid bone defect due to military training injuries who met the selection criteria and admitted between August 2021 and December 2022 were retrospectively analyzed. All patients were male, the age ranged from 21 to 38 years, with an average of 26.8 years. The time from initial dislocation to operation was 6-15 months, with an average of 10.2 months. Anterior shoulder dislocation occurred 5-12 times, with an average of 8.2 times. All glenoid bone defects were more than 10%, including 5 cases of 10%-15%, 8 cases of 15%-20%, and 1 case of 24%. All patients were treated by double EndoButton suture fixation Latarjet procedure. The operation time and complications were recorded. The shoulder function and pain were evaluated by the American Association for Shoulder and Elbow Surgery (ASES) score, Rowe score, Instability Severity Index Score (ISIS), and visual analogue scale (VAS) score before and after operation. The range of motion of the shoulder was recorded, including forward flexion, 0° external rotation, and abduction 90° external rotation. The position, healing, and resorption of the bone mass were evaluated by three-dimensional CT of shoulder joint after operation. Results All patients successfully completed the operation, and the operation time was 100-150 minutes, with an average of 119.7 minutes. There was no complications such as infection, vascular and nerve injury. All patients were followed up 12-20 months, with an average of 15.6 months. During the follow-up, 4 patients had bone mass separation, absorption, and recurrent anterior dislocation, and the shoulder joint fear test was positive. Imaging of the remaining patients showed that the bone mass healed well, no anterior dislocation recurrence occurred, and the healing time was 3-7 months (mean, 4.7 months). At last follow-up, the range of motion, ASES score, Rowe score, ISIS score, and VAS score of the patients significantly improved when compared with those before operation (P<0.05). ConclusionThe effectiveness of double EndoButton suture fixation Latarjet procedure for the treatment of anterior shoulder dislocation with glenoid bone defect caused by military training injury is satisfactory.
Objective To assess the effectiveness of suture button fixation Latarjet procedure under total arthroscopy for anterior shoulder instability with severe bone defects. MethodsThe clinical data of 15 patients with severe bone defects and anterior shoulder instability treated with suture button fixation Latarjet procedure under total arthroscopy between June 2020 and February 2023 was retrospectively analyzed, including 11 males and 4 females, with an average age of 31.1 years (range, 20-54 years). Three-dimensional CT showed that the average glenoid bone defect was 24.4% (range, 16.3%-35.2%). The average number of shoulder dislocation was 4.2 times (range, 3-8 times). The disease duration ranged from 6 to 21 months with an average of 10.6 months. The operation time and intraoperative blood loss were recorded. The pain relief was evaluated by visual analogue scale (VAS) score, and the functional recovery of shoulder joint was evaluated by Rowe score, Walch-Duplay score, and American Association for Shoulder and Elbow Surgery (ASES) score before and after operation. The range of motion (ROM) of the shoulder joint was assessed, including active flexion, lateral external rotation, abduction 90° external rotation, and internal rotation. Three-dimensional CT was performed at 6 months after operation and at last follow-up to observe the absorption of bone graft, the position of bone graft and glenoid, and the healing of bone graft. Results The operation was successfully completed in all patients. The operation time was 85-195 minutes, with an average of 123.0 minutes. The intraoperative blood loss was 20-75 mL, with an average of 26.5 mL. All patients were followed up 13-32 months, with an average of 18.7 months. During the follow-up, there was no serious complication such as shoulder joint infection, joint stiffness, or vascular and nerve injury. One patient had partial absorption of the transplanted bone and bone nonunion at 3 months after operation, but the pain of the shoulder joint relieved at last follow-up, and no redislocation of the shoulder joint occurred; no obvious bone fracture or dislocation of the shoulder joint was found in the other patients. Bone union was achieved at 6 months during follow-up. At last follow-up, the VAS score, Rowe score, Walch-Duplay score, and ASES score significantly improved when compared with those before operation (P<0.05), while the ROM of active flexion, lateral external rotation, abduction 90° external rotation, and internal rotation of the shoulder joint was not significantly different from those before operation (P>0.05).ConclusionSuture button fixation Latarjet procedure under total arthroscopy can improve shoulder joint function in patients with severe anterior shoulder instability caused by bone defects, and imaging also indicates satisfactory placement of transplanted bone blocks.
Objective To evaluate the early-term effectiveness of Latarjet procedure with double EndoButtons fixation for recurrent anterior shoulder dislocation by coracoid osteotomy with preserving coracoacromial ligament. Methods Between January 2021 and June 2023, 19 patients with recurrent anterior shoulder dislocations were treated by arthroscopic Latarjet procedure with double EndoButtons fixation, all of which underwent coracoid osteotomy with preserving the coracoacromial ligament. There were 11 males and 8 females, with an average age of 23.3 years (range, 17-32 years). Shoulder dislocations ranged from 3 to 11 times, with an average of 6.4 times. The disease duration ranged from 3 to 35 months, with an average of 12.9 months. All apprehension tests were positive. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 13%-26%, with an average of 19.8%. After operation, the shoulder range of motion was examined, including flexion lift, lateral external rotation, extension 90° external rotation, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery (ASES) score, and Rowe score. Imaging examinations were taken to observe the position and shaping of coracoid. Results All incisions healed by first intention and no nerve or vessel injury occurred. All patients were followed up 9-24 months (mean, 14.5 months). There was no recurrence of shoulder dislocation and the apprehension tests were negative during follow-up. There was no significant difference in the shoulder range of motion (flexion lift, lateral external rotation, extension 90° external rotation, and internal rotation) between preoperation and at last follow-up (P>0.05). The Walch-Duplay score, ASES score, and Rowe score significantly improved when compared with those before operation (P<0.05). Postoperative imaging showed that coracoid graft was at the same level with the glenoid in all cases; the center of coracoid graft was located between 3 to 5 o’clock. During follow-up, there was no glenohumeral joint degeneration, the acromiaohumeral distance was not reduced when compared with preoperation, and the coracoid bone gradually formed concentric circles with the humeral head. Conclusion The Latarjet procedure with double EndoButtons fixation can effectively treat recurrent anterior shoulder dislocation by coracoid osteotomy with preserving coracoacromial ligament, and the early-term effectiveness is satisfactory.