west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "WANG Shumin" 24 results
  • Expert consensus on the safety of tubeless robotic thymectomy

    Thymectomy is an important treatment for thymoma and myasthenia gravis. The application of minimally invasive surgery to complete thymectomy and rapid recovery of patients after surgery is a developmental goal in thoracic surgery technology. Surgical robots have many technical advantages and are applied for many years in mediastinal tumor resections, a process that has led to its recognition. We published this consensus with the aim of examining how to ensure surgical safety based on the premise that better use of surgical robots achieving rapid recovery after surgery. We invited multiple experts in thoracic surgery to discuss the safety and technical issues of thymectomy under nonintubated anesthesia, and the consensus was made after several explorations and modifications.

    Release date:2022-12-28 06:02 Export PDF Favorites Scan
  • Application of digital drainage system after da Vinci robot-assisted lobectomy: A retrospective cohort study

    Objective To investigate the clinical effect of digital drainage system (DDS) in patients after robot-assisted lobectomy. MethodsThe clinical data of the patients who underwent da Vinci robot-assisted lobectomy from August 2020 to December 2021 were retrospectively analyzed. The patients were divided into a DDS group and a conventional group (using traditional single thoracic drainage tube device) according to different drainage devices used after operation. The preoperative data, intraoperative blood loss, total drainage volume within 48 h after operation, postoperative extubation time and postoperative hospital stay were compared between the two groups. ResultsFinally, 170 patients were collected, including 76 males and 94 females with an average age of 61.8±8.7 years. Postoperative extubation time [5.53 (6.00, 7.00) days vs. 6.36 (6.00, 8.00) days, Z=–2.467, P=0.014] and postoperative hospital stay [7.80 (8.00, 10.00) days vs. 8.94 (9.00, 10.00) days, Z=–2.364, P=0.018] in the DDS group were shorter than those in the conventional group. For patients with postoperative persistent air leak, postoperative extubation time (Z=–2.786, P=0.005) and postoperative hospital stay (Z=–2.862, P=0.003) in the DDS group were also shorter than those in the conventional group. ConclusionDDS has a positive effect on enhanced recovery after robot-assisted lobectomy, which is safe and stable, and is beneficial to postoperative rehabilitation and shortening the average hospital stay.

    Release date:2024-02-20 04:11 Export PDF Favorites Scan
  • Robot-assisted Extended Thymectomy for TypeⅠMyasthenia Gravis Using Da Vinci S System

    Objective To investigate application values and techniques of robot-assisted extended thymectomy for the treatment of typeⅠmyasthenia gravis (MG) using Da Vinci S system. Methods We retrospectively analyzed clinical data of 3 patients with MG who underwent robot-assisted extended thymectomy in General Hospital of Shenyang Military Command from March 2012 to September 2012. All the patients were ocular MG (typeⅠ) including 2 men (33 years and 66 years old respectively) and 1 woman (21 years old). Surgical outcomes were analyzed. Results All the 3 patients successfully received robot-assisted extended thymectomy without accessorial incisions. None of the patients required converting to open sternotomy or postoperative reexploration for bleeding. Intraoperative blood loss was 5-10 ml.Overall operation time was95-138 minutes, and thymoma dissection time was 26-80 minutes. No myasthenic crisis or other major postoperative complic-ation occurred. Postoperative chest drainage duration was 3-9 days and postoperative hospital stay was 10-15 days. Two patientswere followed up for 6-12 months after discharge without MG recurrence. Conclusion Robot-assisted extended thymectomy is safe and feasible for the treatment of typeⅠMG with satisfactory results.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • Chinese expert consensus on robot-assisted pulmonary resections

    Robotic surgery system has been widely used in various types of pulmonary resections. With the unremitting efforts of Chinese thoracic surgeons, the quantity and quality of robotic pulmonary resections in China have reached a remarkable level. With the development and rapid promotion of this technology, the popularity of robotic surgery is also increasing. In order to standardize the clinical practice, guarantee the quality of treatment and promote the development of robotic pulmonary resections, the Committee of Thoracic Surgery, Doctor Society of Medical Robotics, Chinese Medical Doctor Association organized relevant domestic experts to formulate the consensus of Chinese clinical experts on robot-assisted lung cancer surgery.

    Release date:2020-10-30 03:08 Export PDF Favorites Scan
  • Da Vinci robot system in the surgical treatment of mediastinal lesions: A case control study

    Objective To summarize the clinical data about mediastinal lesions, then to analyze the treatment effect of da Vinci robot system in the surgical treatment of mediastinal lesions. Methods We retrospectively analyzed the clinical data of 49 patients with mediastinal lesions in our hospital between January 2016 and October 2017. These patients were divided into two groups including a da Vinci robot group and a video-assisted thoracoscopic surgery (VATS) group according to the selection of the treatments. There were 25 patients with 14 males and 11 females at age of 56.5±17.9 years in the da Vinci group and 24 patient with 15 males and 11 females at age of 53.0±17.8 years in the VATS group. Results There was no statistical difference in surgery time between the two groups (t=–0.365, P=0.681). Less intraoperative blood loss (t=–2.569, P<0.001), less postoperative drainage amount within three days after surgery (t=–6.325, P=0.045), shorter period of bearing drainage tubes after surgery (t=–1.687, P=0.024), shorter hospital stays (t=–3.689, P=0.021), lower visual analogue scale (VAS) scores of postoperative 48 hours (t=–7.214, P=0.014) with a statistical difference in the da Vinci robot group compared with the VATS group. Conclusion The da Vinci robot system is safe and efficient in the treatment of mediastinal lesions compared with video-assisted thoracoscopic approach.

    Release date:2018-05-02 02:38 Export PDF Favorites Scan
  • Robot-assisted Lobectomy for Non-Small Cell Lung Cancer

    Objective To summarize our initial experience in robot-assisted lobectomy for the treatment of non-small cell lung cancer (NSCLC). Methods A total of 20 NSCLC patients underwent robot-assisted pulmonary lobectomy in General Hospital of Shenyang Military Command from March to September 2012. There were 13 males and 7 females, and their age was 43-80 (60.40±8.07) years. Single-direction thoracoscopic lobectomy technique was used,and systemic mediastinal and hilar lymph node dissection was routinely performed during the operation. There were 4 right upper lobectomies,7 right lower lobectomies,1 right middle lobectomy,7 left lower lobectomies,and 1 left upper lobectomy. Results Postoperative pathological examination showed adenocarcinoma in 12 patients,squamous cell carcinoma in 5 patients,adenosquamous carcinoma in 2 patients,and mucoepidermoid carcinoma in 1 patient. One patient undergoing left upper lobectomy had intraoperative pulmonary artery bleeding of 500 ml,who was healed by pulmonary artery repair via an accessory small incision and blood transfusion of 400 ml. All the other 19 patients successfully underwent robot-assisted lobectomy with their mean intraoperative blood loss of 60.00±42.95 (10-200) ml, and no blood transfusion was needed for them. All the patients were successfully extubated after operation, and none of the patients had severe postoperative complication. The mean thoracic drainage time was 9.35±3.48 (3-15) days. All the patients were discharged uneventfully and followed up for 2-9 (6.01±2.09) months without recurrence or metastasis. Conclusions Robot-assisted pulmonary lobectomy using Da Vinci S Surgical System is safe and feasible,and especially advantageous for lymph node dissection. It can be used for the treatment of early stage NSCLC.

    Release date:2016-08-30 05:46 Export PDF Favorites Scan
  • Short- and long-term survival between robot-assisted thoracic surgery and video-assisted thoracoscopic surgery for non-small cell lung cancer: A retrospective cohort study

    Objective To compare the short- and long-term survival of patients with stage T1N0M0 non-small cell lung cancer (NSCLC) undergoing robot-assisted thoracic surgery (RATS) and video-assisted thoracoscopic surgery (VATS). Methods The clinical data of 396 patients with stage T1N0M0 NSCLC treated with RATS or VATS in our hospital from 2012 to 2019 were retrospectively analyzed. There were 209 males and 187 females, with a mean age of 61.58±8.67 years. According to surgical procedures, they were separated into two groups: a RATS group (n=157) and a VATS group (n=239). The two groups were compared in terms of the survival and prognosis-influencing factors. Results The intraoperative blood loss and postoperative 24 h drainage volume in the RATS group were less than those in the VATS group (48±42 mL vs. 182±231 mL, P<0.001; 250±119 mL vs. 324±208 mL, P<0.001). The groups and number of dissected lymph node in the RATS group were more than those of the VATS group (5±2 groups vs. 3±2 groups, P<0.001; 17±9 vs. 11±8, P<0.001). There was no statistical difference in the postoperative 48 h drainage volume (P=0.497), postoperative intubation time (P=0.180) or hospital stay (P=0.313). The survival state and recurrence-free survival state in the VATS group were better than those in the VATS group (1-year survival rate: 98.7% vs. 94.8%, 5-year survival rate: 90.5% vs. 75.8%, 8-year survival rate: 76.9% vs. 62.1%, mean survival time: 93 months vs. 79 months, P=0.005; 1-year recurrence-free survival rate: 97.4% vs. 95.6%, 5-year recurrence-free survival rate: 94.8% vs. 77.8%, 8-year recurrence-free survival rate: 82.6% vs. 64.8%, mean recurrence-free survival time: 95 months vs. 79 months, P=0.004). Univariate analysis showed that surgical method, the groups and the number of dissected lymph nodes were the influencing factors for postoperative overall survival and recurrence-free survival. At the same time, the results of multivariate analysis showed that surgical method was a common independent factor for overall survival and recurrence-free survival.Conclusion RATS can obtain better survival in patients with T1N0M0 NSCLC, and RATS has more thorough lymph node dissection, less intraoperative blood loss and postoperative 24 h drainage volume.

    Release date:2022-09-20 08:57 Export PDF Favorites Scan
  • Feasibility and quality control of robotic sleeve lobectomy and bronchoplasty

    ObjectiveTo explore the feasibility of robotic sleeve lobectomy and bronchoplasty and to summarize the experience of quality control and technical process management.MethodsFrom January to December 2018, our hospital completed robotic sleeve lobectomy and bronchoplasty for 5 patients, including the upper right lung lobe in 2 patients, the middle right lung lobe in 1 patient and the lower left lung lobe in 2 patients. There were 3 males and 2 females with an age of 56.6 (39-75) years. The surgical approach was the same as the surgical incision of the robotic lobectomy. During the operation, the lobes were separated, all enlarged mediastinal lymph nodes were cleaned, pulmonary hilum was dissected, pulmonary arteriovenous vessels and bronchi were exposed, and pulmonary vessels were treated. After exposing the main bronchi, the bronchi were cut off at the distal end of the lesion, and the lobes where the lesion was located (including lesions) were excised by sleeve type and the bronchi were continuously sutured with 3-0 Prolene from the back wall for anastomosis. After the anastomosis, no air leakage was found in the expanded lung, and the anastomosis was no longer wrapped.ResultsThe operation time was 147.4 (100-192) min, including bronchial anastomosis time 17.6 (14-25) min. Intraoperative blood loss was 60.0 (20-100) mL, and 20 (9-37) lymph nodes were dissected. Three patients had squamous cell carcinoma, 1 adenocarcinoma, and 1 neuroendocrine tumor. All patients showed negative results in the freezing pathology of bronchial stump during operation. All patients recovered well after surgery, without perioperative complications, and the anastomosis was smooth. Postoperative hospital stay was 10.8 (7-14) days. The patients were followed up for 6 to 12 months without anastomotic stenosis or other complications.ConclusionSince the robot system is a special instrument with 3D vision and 7 degrees of freedom for movable joints, the robotic bronchial suture is more flexible and accurate. The robotic sleeve lobectomy and bronchoplasty are safe and feasible.

    Release date:2020-02-26 04:33 Export PDF Favorites Scan
  • Efficacy of multidisciplinary team combined with Da Vinci robot-assisted thoracic surgery in the treatment of early non-small cell lung cancer: A retrospective study in a single center

    ObjectiveTo investigate the clinical efficacy of multidisciplinary team (MDT) model combined with Da Vinci robot-assisted thoracic surgery in the treatment of early non-small cell lung cancer (NSCLC). MethodsFrom July 2020 to December 2021, the patients with NSCLC who received Da Vinci robot-assisted thoracic surgery in the Department of Thoracic Surgery, General Hospital of Northern Theater Command were collected. According to whether MDT were performed before hospitalization, the patients were divided into an MDT group and a common group. The recovery and clinical efficacy were compared between the two groups. ResultsA total of 187 patients were enrolled, including 81 males and 106 females, aged 63 (56, 67) years. There were 85 patients in the MDT group, and 102 patients in the common group. Compared with the common group, the MDT group had lower incidence of postoperative complications (9.4% vs. 29.4%, P=0.017), shorter intraoperative operation time [55 (45, 61) min vs. 79 (65, 90) min, P<0.001], and less intraoperative blood loss [25 (20, 30) mL vs. 30 (20, 50) mL, P=0.029] in the same operation mode. In addition, the drainage volume on the second postoperative day [270 (200, 350) mL vs. 215 (190, 300) mL, P=0.004], the number of dissected lymph nodes groups [6 (5, 6) groups vs. 5 (3, 6) groups, P=0.004] and the number of dissected lymph nodes [16 (13, 21) vs. 13 (9, 20), P=0.005] in the MDT group were significantly better than those in the common group. The differences in the postoperative intubation time and postoperative hospital stay between the two groups were not statistically significant (P>0.05). ConclusionMDT combined with Da Vinci robot-assisted thoracic surgery can further reduce the risk of surgery, improve the clinical treatment effect, reduce the incidence of postoperative complications, and accelerate the rehabilitation of patients.

    Release date:2024-02-20 04:11 Export PDF Favorites Scan
  • Advances and prospects in the application of robotic surgery system in the treatment of esophageal cancer

    At present, the application of the robot assisted surgery system in the surgical treatment of esophageal cancer is gradually emerging, and it is more and more widely used and recognized in the field of surgery. According to the domestic and foreign literatures, the robot has many advantages, and robotic assisted esophageal cancer surgery has been proved to be safe and effective, and its short-term efficacy is significantly better than thoracotomy. Other studies have shown that in long-term follow-up, the effect is comparable to video-assisted thoracoscopic surgery. In this paper, the author are systematically reviewed the development history of the robot assisted surgery system, the effect of robotic assisted esophagectomy on safety, surgical method, short-term efficacy and long-term prognosis. The traditional open surgery and thoracoscopic laparoscopic esophagectomy has been carried on the detailed comparison to provide some advice and theoretical basis for esophageal cancer surgery robot system.

    Release date:2019-06-18 10:20 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content