Thoracoscopic minimally invasive technology has been used in mitral valve plasty since 1990s. Totally thoracoscopic mitral valve plasty has the advantages of small trauma, beautiful incision and rapid postoperative recovery. It is favored by more and more patients and cardiac surgeons. However, according to the reports, the proportion of totally thoracoscopic mitral valve surgery in China is still low. Mitral valve plasty via the totally thoracoscopic approach is still controversial in terms of population adaptation, perioperative complications and long-term prognosis. In addition, the technical difficulty and the long training cycle of surgeons also limit the popularization of this technology. By summarizing the existing literature, this paper analyzes the application and development of totally thoracoscopic approach in comparison with the traditional median thoracotomy mitral valve plasty.
ObjectiveTo summarize the early outcomes of totally thoracoscopic minimally invasive aortic valve replacement (AVR) and double valve replacement (DVR).MethodsThe clinical data of patients who underwent totally thoracoscopic minimally invasive AVR or DVR in Guangdong Provincial People’s Hospital from April 2020 to January 2021 were retrospectively analyzed. The patients were divided into an AVR group and a DVR group according to the surgical method, and the clinical data of the two groups were compared.ResultsFinally 22 patients were enrolled, including 14 males and 8 females with an average age of 50.0±11.2 years at operation. Eight patients were degenerative disease, 8 were rheumatic heart disease combined with valvular disease, and 6 were bicuspid aortic valve. Out of the 22 patients, 16 underwent AVR alone, and 6 underwent DVR. All patients completed the operation successfully, and there was no death. Perivalvular leakage during surgery occurred in 2 patients. The average cardiopulmonary bypass time was 187.0±39.9 minutes, and aortic cross-clamping time was 117.0 (99.0, 158.0) minutes. Duration of mechanical ventilation and intensive care unit stay was 9.5 (4.8, 18.3) hours and 41.0 (34.0, 64.0) hours, respectively. The volume of chest drainage at the first 24 hours after surgery was 214.0±124.6 mL, and the postoperative hospital stay was 5.5 (4.0, 8.3) days. The cardiopulmonary bypass time and aortic cross-clamping time in the DVR group were longer than those in the AVR group, and the volume of chest drainage at 24 hours after surgery was more than that in the AVR group, with a statistical difference (P<0.05). Echocardiography before hospital discharge showed paravalvular leakage in 1 patient. There was no death during follow-up of 5.9±3.0 months. ConclusionThe early outcome of totally thoracoscopic minimally invasive AVR and DVR is satisfactory, and the approach of surgery is worth exploring.
ObjectiveTo investigate the predictive value of right atrial myocardial fibrosis in the prognosis of isolated tricuspid regurgitation surgery after left heart valve surgery. MethodsThe patients who underwent tricuspid valvuloplasty by the same operator in Guangdong Provincial People's Hospital from April 2016 to August 2021 due to long-term isolated severe tricuspid regurgitation after left heart valve surgery were included in the study. According to the degree of right atrial myocardial fibrosis, the patients were divided into three groups: a mild group, a moderate group, and a severe group. The clinical data of these patients were compared and analyzed. ResultsA total of 75 patients were enrolled, including 16 males and 59 females with an average age of 57.0±8.4 years. There were 30 patients in the mild group, 29 patients in the moderate group and 16 patients in the severe group. In terms of the preoperative data, there were statistical differences in cardiac function grade, right atrial diameter, tricuspid incompetence area among the three groups (P<0.05). In terms of the postoperative data, there were statistical differences among the three groups in the cardiopulmonary bypass time, mechanical ventilation time, ICU monitoring time, complication rate and mortality (P<0.05). Further pairwise comparison showed that, compared with the mild group, the severe group had longer mechanical ventilation time (P=0.024), longer ICU monitoring time (P=0.003) and higher incidence of postoperative complications (P=0.024), while the moderate group had no statistical difference in all aspects (P>0.05); compared with the moderate group, the severe group had longer ICU monitoring time (P=0.021) and higher incidence of complications (P=0.006). ConclusionThe early outcome of tricuspid valvuloplasty in patients with isolated tricuspid regurgitation after left heart valve surgery with severe right atrial myocardial fibrosis is worse than that in the patients with mild and moderate fibrosis, suggesting that the degree of myocardial fibrosis in the right atrium can be a predictor of the effect of tricuspid regurgitation surgery and a judgement indicator of the surgery timing.
ObjectiveTo examine the safety, efficacy and durability of totally endoscopic minimally invasive (TEMI) mitral valve repair in Barlow’s disease (BD). MethodsA retrospective study was performed on patients who underwent mitral valve repair for BD from January 2010 to June 2022 in the Guangdong Cardiovascular Institute. The patients were divided into a MS group and a TEMI group according to the surgery approaches. A comparison of the clinical data between the two groups was conducted. ResultsA total of 196 patients were enrolled, including 133 males and 63 females aged (43.8±14.9) years. There were 103 patients in the MS group and 93 patients in the TEMI group. No hospital death was observed. There was a higher percentage of artificial chordae implantation in the TEMI group compared to the MS group (P=0.020), but there was no statistical difference between the two groups in the other repair techniques (P>0.05). Although the total operation time between the two groups was not statistically different (P=0.265), the TEMI group had longer cardiopulmonary bypass time (P<0.001) and aortic clamp time (P<0.001), and shorter mechanical ventilation time (P=0.025) and postoperative hospitalization time (P<0.001). No statistical difference between the two groups in the adverse perioperative complications (P>0.05). The follow-up rate was 94.2% with a mean time of 0.2-12.4 (4.0±2.4) years. Two patients in the MS group died with non-cardiac reasons during the follow-up period. The 3-year, 5-year and 10-year survival rates of all patients were 99.2%, 99.2%, and 82.6%, respectively. Compared with the MS group, there was no statistical difference in the survival rate, recurrence rate of mitral regurgitation, reoperation rate of mitral valve or adverse cardiovascular and cerebrovascular events in the TEMI group (P>0.05). ConclusionTEMI approach is a safe, feasible and effective approach for BD with a satisfying long-term efficacy.
ObjectiveTo research the procedure for creating an animal model of mitral regurgitation by implanting a device through the apical artificial chordae tendineae, and to assess the stability and dependability of the device. MethodsTwelve large white swines were employed in the experiments. Through a tiny hole in the apex of the heart, the artificial chordae tendineae of the mitral valve was inserted under the guidance of transcardiac ultrasonography. Before, immediately after, and one and three months after surgery, cardiac ultrasonography signs were noted. Results All models were successfully established. During the operation and the follow-up, no swines died. Immediately after surgery, the mitral valve experienced moderate regurgitation. Compared with preoperation, there was a variable increase in the amount of regurgitation and the values of heart diameters at a 3-month follow-up (P<0.05). ConclusionIn off-pump, the technique of pulling the mitral valve leaflets with chordae tendineae implanted transapically under ultrasound guidance can stably and consistently create an animal model of mitral regurgitation.
Objective To develop a novel transcatheter tricuspid valve replacement device and test its performance. MethodsThe transcatheter tricuspid valve stent consisted of double-layer self-expanding nitinol stent, biotissue-derived bovine pericardial leaflets, and PTFE woven. The delivery system, mainly consisting of a handle control unit and a delivery sheath, was sent to the correct position via right atrium or jugular vein. The sheath had a visualization feature, and the handle control unit could realize the functions of stable release and partial recovery of the interventional valve. In addition, this study performed animal survival experiments on the basis of in vitro experiments. A large-white pig was used as the experimental animal. Cardiopulmonary bypass was established through median thoracotomy, then the right atrium was opened, and the interventional valve was released under direct vision without cardiac arrest. Approximately 1 month after interventional valve implantation, the maneuverability and stability of the interventional tricuspid device were evaluated by autopsy. ResultsThrough the animal experiment, the interventional valve was successfully released, and the anchoring was satisfactory. Postoperative transthoracic echocardiography showed that the interventional valve opened and closed well, the flow rate of tricuspid valve was 0.6 m/s, and there was no obvious tricuspid regurgitation. One month after the operation, we dissected the large-white pig and found the interventional valve was not deformed or displaced, the leaflets were well aligned, and there was thrombus attachment in the groove between the inner and outer layers of the interventional valve. ConclusionAnimal experiment shows that the novel device can stably and firmly attach to the tricuspid annulus, with good anchoring effect, and effectively reduce paravalvular leakage.