west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "distribution" 62 results
  • Study of the Influence of Uniform Transverse Magnetic Field on the Dose Distribution of High Energy Electron Beam Using Monte Carlo Method

    In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.

    Release date: Export PDF Favorites Scan
  • Distribution and Drug Resistance of Acinetobacter baumannii Isolated from Inpatients in Ruijin Hospital from 2008 to 2012

    ObjectiveTo study the clinical distribution and the change of drug resistance of Acinetobacter baumannii from different inpatient specimens sources during 2008 to 2012, and to provide guidance for rational use of antibiotics. MethodsThe identification of Acinetobacter baumannii was conducted by VITEK-2 based on clinical and laboratory standards institute (CLSI) guideline between January 2008 and December 2012. The susceptibility of antibiotics was determined by K-B test, and data analysis was conducted by Excel and SAS. ResultsA total of 3 139 stains of Acinetobacter baumannii were isolated from 2013 patients during this period. The Acinetobacter baumannii was mainly obtained from the Burn ward, Intensive Care Unit ward and Thoracic ward. Sputum was the most specimens of Acinetobacter baumannii, accounting for 48.4%. The drug resistance rates of Acinetobacter baumannii to most of the antimicrobial agents were more than 55%. Compound antibacterial is more effective than the single drug ingredient. Compared with other antimicrobial agents, β-lactams/β-lactamase inhibitor compound and carbapenems antimicrobial agents were more sensitive. ConclusionThe drug resistance of Acinetobacter baumannii is serious and has differences among hospitals. Clinicians should monitor the drug resistance of Acinetobacter baumannii timely and choose proper antibiotics according to the results of drug sensitivity.

    Release date: Export PDF Favorites Scan
  • Study on the geometric characteristics and distribution of porosities in three-dimensional printed Ti-6Al-4V titanium alloy

    Three dimensional (3D) printing is considered as an advanced manufacturing technology because of its additive nature. Electron beam melting (EBM) is a widely used 3D printing processes for the manufacturing of metal components. However, the products printed via this process generally contain micro porosities which affect mechanical properties, especially the fatigue property. In this paper, two types of EBM printed samples of the Ti-6Al-4V alloy, one with a round cross section and the other with a triangle cross section, were employed to investigate the existence of porosities using computed tomography (CT). Statistical analyses were conducted on the number, volume, shape, and distribution of pores. The results show that small pores (less than 0.000 2 mm3) account for 80% of all pores in each type of samples. Additionally, to some extent, the shape of sample has influence on the number of micro porosities in EBM made Ti-6Al-4V. The sphericity of the pores is relatively low and is inversely proportional to pore volume. It is found that re-melting on the free surface effectively reduce pore density near the surface. This study may help produce a medical implant with better fatigue resistance.

    Release date:2017-12-21 05:21 Export PDF Favorites Scan
  • Application of hyperbolic heat transfer model in atrial fibrillation microwave ablation

    The effect of relaxation time in hyperbolic heat transfer model on the temperature field of microwave ablation of atrial fibrillation was investigated. And the results were compared with those calculated by Pennes model. A three-dimensional model of microwave ablation of atrial fibrillation was constructed. The relaxation time (τ) was 0, 1, 5, 8, 10, 15 and 20 s, respectively. And the temperature field of myocardial tissue was obtained. The results showed that the highest temperature of the hyperbolic model was 21.8 ℃ lower than that of the Pennes model at the beginning of ablation. With the increase of ablation time, the highest temperature tended to be the same. The lesion dimensions appeared at 3, 4, 6, 7, 8, 9, and 10 s, respectively after ablation. Therefore, the influence of hyperbolic model on temperature will decrease with the increase of the ablation time. At the beginning of ablation, the relaxation time will hinder the speed of myocardial thermal diffusion. The larger the relaxation time is, the slower the speed of thermal diffusion is. This study provides a reference for the application of hyperbolic model in microwave ablation of atrial fibrillation.

    Release date:2021-12-24 04:01 Export PDF Favorites Scan
  • Difference of compensatory mechanisms in bilateral knee osteoarthritis patients of varying severity

    Objective To investigate the load distribution on the more painful and less painful limbs in patients with mild-to-moderate and severe bilateral knee osteoarthritis (KOA) and explore the compensatory mechanisms in both limbs among bilateral KOA patients with different severity levels. Methods A total of 113 participants were enrolled between July 2022 and September 2023. This cohort comprised 43 patients with mild-to-moderate bilateral KOA (Kellgren-Lawrence grade 2-3), 43 patients with severe bilateral KOA (Kellgren-Lawrence grade 4), and 27 healthy volunteers (healthy control group). The visual analogue scale (VAS) score for pain, the Hospital for Special Surgery (HSS) score, passive knee range of motion (ROM), and hip-knee-ankle angle (HKA) were used to assess walking pain intensity, joint function, and lower limb alignment in KOA patients, respectively. Motion trajectories of reflective markers and ground reaction force data during walking were captured using a gait analysis system. Musculoskeletal modeling was then employed to calculate biomechanical parameters, including the peak knee adduction moment (KAM), KAM impulse, peak joint contact force (JCF), and peak medial/lateral contact forces (MCF/LCF). Statistical analyses were performed to compare differences in clinical and gait parameters between bilateral limbs. Additionally, one-dimensional statistical parametric mapping was utilized to analyze temporal gait data. Results Mild-to-moderate KOA patients showed the significantly higher HSS score (67.7±7.9) than severe KOA patients (51.9±8.9; t=8.747, P<0.001). The more painful limb in all KOA patients exhibited significantly greater HKA and higher VAS scores compared to the less painful limb (P<0.05). While bilateral knee ROM did not differ significantly in mild-to-moderate KOA patients (P>0.05), the severe KOA patients had significantly reduced ROM in the more painful limb versus the less painful limb (P<0.05). Healthy controls showed no significant bilateral difference in any biomechanical parameters (P>0.05). All KOA patients demonstrated longer stance time on the less painful limb (P<0.05). Critically, severe KOA patients exhibited significantly higher peak KAM, KAM impulse, and peak MCF in the more painful limb (P<0.05), while mild-to-moderate KOA patients showed the opposite pattern with lower peak KAM and KAM impulse in the more painful limb (P<0.05) and a similar trend for peak MCF. Conclusion Patients with mild-to-moderate KOA effectively reduce load on the more painful limb through compensatory mechanisms in the less painful limb. Conversely, severe bilateral varus deformities in advanced KOA patients nullify compensatory capacity in the less painful limb, paradoxically increasing load on the more painful limb. This dichotomy necessitates personalized management strategies tailored to disease severity.

    Release date:2025-07-11 10:05 Export PDF Favorites Scan
  • Quantitative Analysis of Bias of Each Study in Meta-analysis

    ObjectiveStudy how to quantify the bias of each study and how to estimate them. MethodIn the random-effect model, it is commonly assumed that the effect size of each study in meta-analysis follows a skew normal distribution which has different shape parameter. Through introducing a shape parameter to quantify the bias and making use of Markov estimation as well as maximum likelihood estimation to estimate the overall effect size, bias of each study, heterogeneity variance. ResultIn simulation study, the result was closer to the real value when the effect size followed a skew normal distribution with different shape parameter and the impact of heterogeneity of random effects meta-analysis model based on the skew normal distribution with different shape parameter was smaller than it in a random effects metaanalysis model. Moreover, in this specific example, the length of the 95%CI of the overall effect size was shorter compared with the model based on the normal distribution. ConclusionIncorporate the bias of each study into the random effects meta-analysis model and by quantifying the bias of each study we can eliminate the influence of heterogeneity caused by bias on the pooled estimate, which further make the pooled estimate closer to its true value.

    Release date:2016-10-02 04:54 Export PDF Favorites Scan
  • Stress Analysis of Cervical Spine C4-C6 Under Frontal Impact Load

    In order to check the neck response and injury during motor vehicle accidents, we developed a detailed finite element model for human cervical spine C4-C6. This model consisted of cortical bone, cancellous bone, annulus, nucleus, ligaments and articular facet, and it also set up contact in the contacting parts for simulating the movement perfectly under frontal impact. This model could be used for stress and strain distribution after the frontal impact load was applied on this model. During the process of frontal impact, the most displacement simulated data were in the interval range of experimental data. The experimental results showed that this model for the human cervical spine C4-C6 simulated the movement under the frontal impact with fidelity, and reflected the impact dynamics response on the whole.

    Release date: Export PDF Favorites Scan
  • Evoked Potential Blind Extraction Based on Fractional Lower Order Spatial Time-Frequency Matrix

    The impulsive electroencephalograph (EEG) noises in evoked potential (EP) signals is very strong, usually with a heavy tail and infinite variance characteristics like the acceleration noise impact, hypoxia and etc., as shown in other special tests. The noises can be described by α stable distribution model. In this paper, Wigner-Ville distribution (WVD) and pseudo Wigner-Ville distribution (PWVD) time-frequency distribution based on the fractional lower order moment are presented to be improved. We got fractional lower order WVD (FLO-WVD) and fractional lower order PWVD (FLO-PWVD) time-frequency distribution which could be suitable for α stable distribution process. We also proposed the fractional lower order spatial time-frequency distribution matrix (FLO-STFM) concept. Therefore, combining with time-frequency underdetermined blind source separation (TF-UBSS), we proposed a new fractional lower order spatial time-frequency underdetermined blind source separation (FLO-TF-UBSS) which can work in α stable distribution environment. We used the FLO-TF-UBSS algorithm to extract EPs. Simulations showed that the proposed method could effectively extract EPs in EEG noises, and the separated EPs and EEG signals based on FLO-TF-UBSS were almost the same as the original signal, but blind separation based on TF-UBSS had certain deviation. The correlation coefficient of the FLO-TF-UBSS algorithm was higher than the TF-UBSS algorithm when generalized signal-to-noise ratio (GSNR) changed from 10 dB to 30 dB and α varied from 1.06 to 1.94, and was approximately equal to 1. Hence, the proposed FLO-TF-UBSS method might be better than the TF-UBSS algorithm based on second order for extracting EP signal under an EEG noise environment.

    Release date: Export PDF Favorites Scan
  • Nonparametric Method of Estimating Survival Functions Containing Right-censored and Interval-censored Data

    Missing data represent a general problem in many scientific fields, especially in medical survival analysis. Dealing with censored data, interpolation method is one of important methods. However, most of the interpolation methods replace the censored data with the exact data, which will distort the real distribution of the censored data and reduce the probability of the real data falling into the interpolation data. In order to solve this problem, we in this paper propose a nonparametric method of estimating the survival function of right-censored and interval-censored data and compare its performance to SC (self-consistent) algorithm. Comparing to the average interpolation and the nearest neighbor interpolation method, the proposed method in this paper replaces the right-censored data with the interval-censored data, and greatly improves the probability of the real data falling into imputation interval. Then it bases on the empirical distribution theory to estimate the survival function of right-censored and interval-censored data. The results of numerical examples and a real breast cancer data set demonstrated that the proposed method had higher accuracy and better robustness for the different proportion of the censored data. This paper provides a good method to compare the clinical treatments performance with estimation of the survival data of the patients. This provides some help to the medical survival data analysis.

    Release date: Export PDF Favorites Scan
  • Research on Time-frequency Characteristics of Magneto-acoustic Signal of Different Thickness Medium Based on Wave Summing Method

    Functional imaging method of biological electrical characteristics based on magneto-acoustic effect gives valuable information of tissue in early tumor diagnosis, therein time and frequency characteristics analysis of magneto-acoustic signal is important in image reconstruction. This paper proposes wave summing method based on Green function solution for acoustic source of magneto-acoustic effect. Simulations and analysis under quasi 1D transmission condition are carried out to time and frequency characteristics of magneto-acoustic signal of models with different thickness. Simulation results of magneto-acoustic signal were verified through experiments. Results of the simulation with different thickness showed that time-frequency characteristics of magneto-acoustic signal reflected thickness of sample. Thin sample, which is less than one wavelength of pulse, and thick sample, which is larger than one wavelength, showed different summed waveform and frequency characteristics, due to difference of summing thickness. Experimental results verified theoretical analysis and simulation results. This research has laid a foundation for acoustic source and conductivity reconstruction to the medium with different thickness in magneto-acoustic imaging.

    Release date: Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content