west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "valve replacement" 312 results
  • Clinical application of Commando procedure in reoperation for mechanical valve dysfunction

    ObjectiveTo explore the feasibility and effectiveness of Commando procedure for mechanical valve dysfunction requiring reoperation. Methods The clinical data of patients who received Commando surgery (aortic/mitral curtain enlargement+valve replacement surgery) in the Department of Cardiovascular Surgery of Gaozhou People's Hospital from December 2021 to September 2022 were retrospectively analyzed. These patients who had undergone mechanical mitral or aortic valve replacement and then had mechanical valve dysfunction with mitral or aortic valve lesions requiring repeat combined valve replacement surgery were selected. Results Eleven patients were enrolled, including 2 males and 9 females, aged 63.63±11.64 years. All 11 patients successfully underwent the Commando operation, and were implanted with suitable artificial valves, among which the aortic valve size was 27.00±2.00 mm, and the mitral valve size was 27.72±3.13 mm. Cardiopulmonary bypass time was 195.81±39.29 min, aortic cross-clamping time was 121.81±28.60 min, mechanical ventilation time was 15.09±3.72 h, ICU stay time was 3.09±0.70 days, and total postoperative thoracic drainage volume was 417.18±68.65 mL. There was no perioperative death. ConclusionCommando procedure is a safe and effective method to perform combined valve operation for mechanical valve dysfunction. A larger artificial valve can be implanted during the procedure to obtain sound hemodynamic effects. In addition, for elderly patients, a suitable type of bioprosthetic valve can be implanted to improve the patient's quality of life. The early surgical effect is satisfactory, and the long-term impact needs further follow-up.

    Release date:2024-05-28 03:37 Export PDF Favorites Scan
  • Effects of Tight Blood Glucose Control on the Shortterm Prognosis of the Patients after Heart Valve Replacement

    Objective To investigate the effects of tight blood glucose control on the shortterm prognosis of the patients after heart valve replacement, in order to improve treatment effectiveness and lower postoperative complications. Methods A total of 240 patients including 150 males and 90 females underwent mitral valve replacement or mitral and aortic valve replacement were enrolled in this study from January 2007 to December 2008 at the cardiac surgery department of Renmin hospital of Wuhan university. The age of these patients ranged from 19 to 65 years old with an average age of 53.33 years. According to insulin administration time and blood glucose control level, they were randomly separated into two groups. In the experimental group, there were 121 patients who received continuous insulin infusion to maintain postoperative glucose level between 4.4 and 6.1 mmol/L, while 119 patients in the control group received insulin infusion when their glucose level went higher than 11.1 mmol/L to control the level between 6.1 and 11.1 mmol/L. Then the postoperative wound infection, malignant arrhythmia rate, the assisted ventilation time, intensive care unit(ICU) stay time and count of neutrophils were compared and analyzed. Results There was no hospitalized death in both groups. The rate of wound infection(3.31% vs.10.08%, χ2=4.430,P=0.035), the assisted ventilation time(9.02±2.73 h vs. 10.01±3.58 h, t=2.280,P=0.024), time for count of leukocytes to decrease to the normal level(11.04±3.16 d vs. 12.05±3.76 d, t=2.168,P=0.031), average hospitalization time(13.49±3.81 d vs. 14.51±4.02 d,t=2.017,P=0.045), and count of neutrophils on the third day(0.82±0.04 vs. 0.84±0.05, t=2.644,P=0.009) in the experimental group were significantly lower or shorter than those in the control group. But there was no significant difference between both groups in ICU stay time and the rate of malignant arrhythmia. Conclusion Tight blood glucose control can lower the rate of postoperative wound infection, shorten the assisted ventilation time and hospitalization time, and reduce the usage of antibiotics in patients after heart valve replacement. Accordingly, it can enhance the curative effect, reduce overall medical expenses, and improve prognosis.

    Release date:2016-08-30 05:59 Export PDF Favorites Scan
  • Development of transcatheter heart valve therapy in the world in 2020

    In 2020, due to the impact of the novel coronavirus epidemic, the development of transcatheter heart valve therapy has been shown to slow down, but there are still many aspects worth noting. The indication of monoclonal antibody after transcatheter aortic valve replacement (TAVR) should be further clarified. Low surgical risk patients were included in TAVR relative indications. Mitraclip G4 was approved by CE. The indication of atrial septal occlusion after mitraclip should be further clarified. The technique of coaptation augmentation is expected to become a new method of mitral valve interventional repair. Tendyne transcatheter mitral valve was approved by European Union. Transcatheter tricuspid valve treatment equipments, TriClip and PASCAL obtained CE mark. TAVR technology is being popularized rapidly in China, and what’s more, balloon dilated valve Sapien 3 and new recyclable repositioning valve system-Venus plus have entered the domestic market. A number of mitral valve therapeutic instruments have appeared one after another, and China's first tricuspid valve lux has completed its FIM research. Finally, with the improvement of devices and technology in the future, interventional therapy of heart valve is expected to benefit more patients.

    Release date:2021-04-25 09:57 Export PDF Favorites Scan
  • Comparative Study of Efficacy Between 6-Epsilon-aminocaproic Acid and Aprotinin on Reducing Bleeding after Cardiac Valve Replacement

    Objective To compare the efficacy of 6-epsilon-aminocaproic acid (EACA) with aprotinin on reducing postoperative bleeding in cardiac valve replacement procedures, and to investigate its influence on the possible thromboembolism and the renal function. Methods Seventy-nine patients who underwent cardiac valve replacement were randomly divided into two groups: EACA group (n = 39) and aprotinin group (n = 40), which were given EACA and aprotinin separately in operations. The volumes of drainage to body surface area (BSA), blood transfusion were recorded during 24 h after operations. The concentrations of serum D-dimer and α2-antiplasmin (a2- AP) were measured before, during operation and at 72h post-operatively. The serum creatinine levels before operation and at the 72 h after operation were also measured. Results The volume ratio of drainage to BSA in EACA group was significantly higher than that in the aprotinin group at 24 h after operation (P = 0. 019). However, there was no significant difference in the volumes of blood transfusion between two groups (P〉0. 05). Also no statistical difference in the concentrations of D-dimer and a2-AP were found between two groups whether preoperatively or at 72h post-operatively (P= 0. 960,0. 485), D-dimer and a2-AP of the aprotinin group were higher than those in the EACA group after aortic off-clamping (P = 0. 001,0. 000). There was no statistically difference of △CrCl72 in both groups (P〉0. 05). No patient with thrombosis or thromboembolism was detected in two groups.Conclusion Although the efficacy of EACA in reducing postoperative bleeding in cardiac valve replacement can not compare favorably with that of aprotinin, the blood transfusion volume would not increase when EACA is used introoperatively. Proper usage of EACA will not cause thrombosis and renal damage.

    Release date:2016-08-30 06:22 Export PDF Favorites Scan
  • Advantages and related developments of self-expandable valves for transcatheter aortic valve replacement

    Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.

    Release date:2023-12-25 11:45 Export PDF Favorites Scan
  • A case report of acute prothesis thrombosis after emergent transcatheter aortic valve replacement

    This article reports a patient diagnosed with severe aortic stenosis. After admission, the cardiac multidisciplinary team performed transcatheter aortic valve replacement (TAVR) emergently due to its unstable hemodynamics. The procedure was successful, and the initial cardiogram during the operation after TAVR suggested that the stenosis was greatly improved. But gradually the next day bedside echocardiography suggested that the transvalvular pressure difference increased and the prosthetic valve forward blood flow accelerated. Acute valve thrombosis after TAVR was taken into consideration. Warfarin and heparin were administrated for anticoagulation, after which the pressure difference across the valve and the forward blood flow rate of the artificial valve were evenly improved.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Functional tricuspid regurgitation: Current understanding

    Functional tricuspid regurgitation is referred to tricuspid regurgitation due to enlargement of right ventricular and dilation of tricuspid annulus. Patients with chronic progressive tricuspid regurgitation have poor prognosis, poor quality of life and heavy economic burden. This article provides a comprehensive review of functional tricuspid regurgitation in terms of anatomical basis, pathological stage, imaging assessment and surgical decision making.

    Release date:2020-06-29 08:13 Export PDF Favorites Scan
  • Exploration of the application of transcatheter aortic valve replacement for moderate aortic stenosis

    Current guidelines recommend follow-up observation for moderate aortic stenosis (MAS), but clinical evidence shows that its prognosis is poor, especially when combined with left ventricular systolic dysfunction, the risk of death and hospitalization for heart failure is significantly increased. With the technical maturity and device development of transcatheter aortic valve replacement (TAVR), its therapeutic potential in MAS has attracted attention. This paper systematically reviewes the risk stratification indicators of MAS and the clinical research results of early TAVR intervention, and analyzes the key clinical issues such as patient selection and operation timing. It points out that early TAVR may improve the prognosis and quality of life of some high-risk MAS patients, but its wide clinical application still needs more evidence-based medical evidence support.

    Release date:2025-10-27 04:22 Export PDF Favorites Scan
  • Research progress of transcatheter aortic valve replacement-related new valve prostheses

    Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.

    Release date:2023-09-28 02:17 Export PDF Favorites Scan
  • Effect of transcatheter aortic valve replacement on postoperative left ventricular reverse remodeling in patients with aortic regurgitation

    Objective To investigate the left ventricular reverse remodeling (LVRR) in patients with aortic valve insufficiency with reduced ejection fraction (AIrEF) and aortic valve insufficiency with preserved ejection fraction (AIpEF) after transcatheter aortic valve replacement (TAVR). MethodsThe clinical and follow-up data of patients who underwent TAVR in the Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from 2018 to 2021 were retrospectively analyzed. According to the guideline, the patients with left ventricular ejection fraction<55% were allocated to an AIrEF group, and the patients with left ventricular ejection fraction≥55% were allocated to an AIpEF group. ResultsA total of 50 patients were enrolled. There were 19 patients in the AIrEF group, including 15 males and 4 females with a mean age of 74.5±7.1 years. There were 31 patients in the AIpEF group, including 19 males and 12 females with a mean age of 72.0±4.8 years. All patients underwent TAVR successfully. Echocardiographic results showed that TAVR significantly promoted LVRR in the patients. Significant LVRR occurred in the early postoperative period (the first day after the surgery) in both groups. It remained relatively stable after the LVRR in the early postoperative period (the first day after surgery) in the AIpEF patients, while it continued to occur in the early postoperative period (the first day after surgery) to three months after the surgery in the AIrEF patients, and then remained relatively stable. Compared to preoperative values, AIrEF patients had a reduction in the average left ventricular end-diastolic volume index and left ventricular end-systolic volume index by 16.8 mL/m2 (P=0.003) and 8.6 mL/m2 (P=0.005), respectively, and the average left ventricular end-diastolic diameter index and end-systolic diameter index decreased by 2.5 mm/m2 (P=0.003) and 1.9 mm/m2 (P=0.003), respectively on the first day after the surgery. In comparison to the first day after the surgery, AIrEF patients experienced an average increase of 12.1% in the left ventricular ejection fraction three months after the surgery (P<0.001). ConclusionTAVR has achieved good therapeutic effects in patients with aortic valve insufficiency, significantly promoting the LVRR in patients, and has better curative effects in AIrEF patients.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
32 pages Previous 1 2 3 ... 32 Next

Format

Content