west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "体层摄影术,光学相干/利用" 6 results
  • 视网膜血管疾病的光相干断层扫描检查图像解读

    糖尿病视网膜病变、视网膜动静脉血管阻塞等视网膜血管疾病光相干断层扫描(OCT)检查可以发现视网膜出血、渗出、玻璃体视网膜界面异常等图像特征;了解其光感受器细胞受损程度。正确认识视网膜血管疾病的OCT图像特征,探讨其形成机制的组织学基础,有助于加深对视网膜血管疾病发生发展转归过程的了解,对视网膜血管疾病诊断、预后判断和提高临床治疗效果具有重要意义。

    Release date:2016-09-02 05:26 Export PDF Favorites Scan
  • Clinical analysis of 18 patients with acute zonal occult outer retinopathy

    Objective To observe the clinical features of acute zonal occult outer retinopathy (AZOOR).Methods Eighteen patients (18 eyes) with AZOOR were enrolled in this study. All the patients were examined for corrected visual acuity, fundus examination, visual field and electroretinography (ERG). For part of these patients, fluorescein angiography (FFA), optic coherence tomography (OCT), visual evoked potential (VEP) and multifocal ERG (mf-ERG) were performed. Clinical features were observed. Comparative analysis was performed on the electrophysiological results between affected eyes and fellow eyes. The consistency of OCT, visual field and mf-ERG results was investigated.Results The patients included three males and 15 females. All patients were unilateral involved. 16 eyes (88.9%) were myopia, two eyes (11.1%) were emmetropia. 11 eyes (61.1%) have normal fundus; single yellow-white punctuate lesion or old RPE lesion near macular were found in three eyes (16.7%); depigmented zones in temporal retina were found in four eyes (22.2%). All central visual field results were abnormal, but peripheral visual field results were normal. OCT findings included irregularity, absence or breaks of the photoreceptor inner segment/outer segment (IS/OS) junction. Amplitudes of full-field ERG were reduced in the affected eyes (t=3.516,2.689,3.103,3.517,2.999,3.309;P<0.05), and implicit times were delayed in most responses except for rod response (t=1.023,P=0.306). Amplitudes of P100 wave of visual evoked potential were reduced statistically (t=2.04,P=0.041), but the differences of implicit times between the affected eyes and the fellow eyes were not statistically significant (t=1.687,P=0.092). Amplitude reduction of multifocal ERG existed in all affected eyes. Coincidence was found between results of OCT and mf-ERG. But abnormal zones found by central visual field did not always coincide with those by mf-ERG. Conclusions The majority of patients who develop AZOOR are young women with myopia. Most patients have normal fundus. Central visual field and electrophysiological examinations are always abnormal. Irregularity, absence or breaks of the photoreceptor IS/OS junction can be proved by OCT.

    Release date:2016-09-02 05:26 Export PDF Favorites Scan
  • Ophthalmoscopic image characteristics and relation with vision and course of disease in nonarteritic anterior ischemic optic neuropathy

      Objective To observe the characteristics of fundus fluorescein angiography(FFA)and optical coherence tomography(OCT)in nonarteritic anterior ischemic optic neuropathy (NAION),and investigate its relation with visual acuity and course of disease.Methods The clinical data of 47 patients (47 eyes) with NAION were retrospectively analyzed. All the patiens had undergone visual acuity,fundus and visual field examination,meanwhile FFA and OCT were carried out at first visit. FFA and visual field were carried out by routine. OCT was carried out by line and circle shape scanning in macula and optic disc. Thirtyfive NAION patients were checked with OCT at half, one, two, three and six month after onset in respectively. Take the healthy fellow eyes of 36 NAION patiens as control group.The FFA,visual field,OCT characteristics and relation with visual acuity and course disease were comparatively analyzed.ResultsFFA showed that all the eyes appear as delayed filling of the optic disc in early stage and hyperfluorescence leakage of the optic disc in late stage,besides hyperfluorescence presented to macular area in 24 eyes. OCT showed that optic papilla swelling and physiological depression narrow or nearly disappearance, neuroepithelial layer thickening or neuroepithelial layer eminence and subretinal fluidity area opaca between optic disc and macula. There were 14 eyes with normal physiological depression and 22 eyes with small physiological depression or non physiological depression in control group. Half month after onset,the neuroepithelial layer thickness of macula fovea, the maximum thickness of neuroepithelial layer between optic disc and macula,and the average retinal nerve fiber layer(RNFL)thickness in NAION group were higher than those in the control group,the difference were statistically significant (F=6.51,26.12,75.49;P<0.05).Two months after onset,the maximum thickness of neuroepithelial layer between optic disc and macula, the average RNFL thickness, and the RNFL thickness of temporal optic disc in NAION group were significant thinner, but the elevated height of the optic disc in NAION group were near those of the control group. Three months after onset,the average RNFL thickness and the RNFL thickness of temporal optic disc in NAION group decreased continually, they were lower than those of the control group, the difference were statistically significan(F=75.49,37.92;P<0.05).Visual field showed that inferior defect were found in 21 eyes (45%). With progress, the superior RNFL thickness obviously decreased, coincidence with appearance of visual field. It indicate that the superior optic atrophy serious. Visual acuity had significant negative correlation with the neuroepithelial layer thickness of macula fovea, the neuroepithelial layer maximum thickness between optic disc and macula, the average RNFL thickness, the RNFL thickness of temporal optic disc(r=-0.394,-0.424,-0.412,-0.464;P<0.05).Conclusions FFA showes that hyperfluorescence leakage appearanced in part macula. OCT showes that RNFL becomes thinner as the disease duration increases. The results of OCT and visual field examinaion in the configuration of optic disc and changes of RNFL are accordant.

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • Relationship of shallow optic cup and small disc with nonarteritic anterior ischemic optic nerupathy

      Objective To observe the relationship between shallow optic cup,small disc and occurrence in patients with nonarteritic anterior ischemic optic neuropathy (NAION).Methods Ninetysix patients(96 diseased eyes)who accorded with the diagnosis criteria for NAION,with duration ge; three months and optic disc edema in paracmasis were selected. The fellow eyes of 96 NAION patients and 80 normal eyes were selected in our study. The horizontal and vertical disc and cup diameters,optic cup depth, and peripapillary retinal nerve fiber layer (RNFL) thickness were measured by quot;crossquot; and quot;ringquot; scan of optical coherence tomography (OCT,Humphrey 2000,German Carl Zeiss Company) inspection system. The cup depth were classified four grades by cup shape according to OCT images:GradeⅠ,bottom of optic cup above the anterior plane of peripapillary neuroepithelial layer(PNL);GradeⅡ,bottom of optic cup above the plane of PNL;Grade Ⅲ,bottom of optic cup between the plane of PNL and choroidal pigment epithelium;Grade Ⅳ,bottom of optic cup under the plane of choroidal pigment epithelium connection. The grades of optic cup and value in three groups were statistically analyzed. The follow up ranged from six months to three years.Results The disc diameter in horizontal scanning of diseased eyes,fellow eyes and normal eyes were (1.29plusmn;0.19), (1.32plusmn;0.17), (1.40plusmn;0.15) mm,and diameters in vertical scanning were (1.52plusmn;0.14), (1.49plusmn;0.17), (1.60plusmn;0.22) mm, respectively. Compared the diseased eyes and fellow eyes with normal eyes,the difference were statistically significant in horizontal scanning (t=4.291,3.315; P<0.05) and in vertical scanning (t=2.812, 3.654; P<0.05). Compared the diseased eyes with fellow eyes,the difference of average diameter were not statistically significant in horizontal and vertical scanning (t=1.153,1.335; P>0.05). Of the diseased eyes,GradeⅠoptic cup in 36 eyes(37.50),Grade Ⅱ-Ⅲoptic cup in 52 eyes(54.17%),Grade Ⅳoptic cup in eight eyes(8.33%),and GradeⅠ-Ⅲ optic cup in 88 eyes(91.67%)were found. Of the fellow eyes,GradeⅠoptic cup in 18 eyes(18.75%),Grade Ⅱ-Ⅲoptic cup in 69 eyes(71.88%),Grade Ⅳoptic cup in nine eyes(9.34%),and GradeⅠ-Ⅲ optic cup in 87 eyes(9066%)were found. Compared the average RNFL thickness of diseased eyes with the fellow eyes and normal eyes,the differences were statistically significant in temporal, upper, nasal, lower quadrant(t=12.862,10.147,15.046,8.180,12.859,9.562,12.174,8.632;P<0.001). Compared the average RNFL thickness of the fellow eyes and normal eyes,the differences were not statistically significant in all quadrants(t=1.040,1.576,1.062,1.192;P>0.05). During the followup,eight eyes with recurrence which optic cup were GradeⅠand Ⅱin diseased eyes;44 eyes(45.8%)occurred NAION. Correlation analysis showed that there was negative correlation between incidence of fellow eye and optic cup depth(t=-0.757, P=0.000). Conclusion Optic cup and disk in NAION patients are smaller than that in the normal,the anatomical characteristics of shallow cup and small disc was one of the NAION pathogenesis.

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • Changes of retinal nerve fiber layer thickness and its correlation with visual field mean defects in early Parkinson′s disease

      Objective To observe the changes of retinal nerve fiber layer (RNFL) thickness and its correlation with visual field mean defects(MD)in Parkinsonprime;s disease (PD).Methods Fifteen eyes of 15 PD patients in early stage and 18 eyes of 18 normal controls undertook RNFL examination by Stratus OCT3. Circular scans (diameter is 3.46 mm) were taken around the optic nerve head including eight quadrants (superior, inferior, temporal, nasal, temporalsuperior, temporalinferior, nasalsuperior and nasalinferior). The RNFL thickness in different quadrants in the two groups was analyzed. The visual field of PD patients was measured by central 302 program of Humphery750 visual field analyzer, and the MD was recorded. The correlation between RNFL thickness and MD was analyzed by linear correlation and regression analysis.Results RNFL thicknesses of superior, inferior, temporal, nasal, temporalsuperior, temporalinferior, nasalsuperior, nasalinferior and average RNFL thickness in the control group were (132.7plusmn;17.4), (141.5plusmn;15.3) ,(83.2plusmn;17.5), (83.7plusmn;22.3) ,(120.8plusmn;21.2), (117.9plusmn;24.5) ,(109.6plusmn;20.6),(110.2plusmn;27.7), and(109.9plusmn;8.5)mu;m respectively, while in the PD group they were (128.1plusmn;25.3) , (128.6plusmn;13.2) , (68.7plusmn;13.5) , (76.5plusmn;17.8) ,(102.6plusmn;23.7), (103.3plusmn;14.1) ,(101.2plusmn;20.9),(96.6plusmn;15.0),(102.3plusmn;11.9) mu;m. Compared with each other, the differences of RNFL thickness of inferior, temporal, temporalsuperior, temporalinferior and average RNFL thickness were statistically significant(t=2.595,2.700,2.330,2.153,2.131;P=0.014,0.011,0.026,0.040,0.041). There was a close negative relationship between average RNFL thickness and MD in PD patients (r=-0.933,P<0.0001). Conclusions RNFL thickness was significantly thinner in PD patients than that in the normal controls. There was a negative relationship between RNFL thickness and MD in PD patients.

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • Application of Micron Ⅳ retinal imaging system in three different types of mouse models

    ObjectiveTo evaluate Micron Ⅳ retinal imaging system in three mouse models of retinal diseases. MethodsMouse models of oxygen induced retinopathy (OIR) model (OIR group), N-methyl-N nitrosourea (MNU) model (MNU group) and N-methyl-D-aspartate (NMDA) model (NMDA group) were induced in 24 healthy male C57BL/6J mice. Fundus photograph, fundus fluorescein angiography (FFA) and optical coherence tomography (OCT) and electroretinogram (ERG) were used to evaluate these mice. All the imaging examinations were performed by Micron Ⅳ retinal imaging system. ResultsOIR mice showed tortuous and dilated retinal vessels in fundus photograph, neovascularization plexus and vascular leakage in FFA, and epiretinal fibrovascular tissue and tortuous expansion vascular vessels in OCT. MNU mice showed wax yellow optic disk without retinal pigmentary changes, slight thinning of retinal blood vessels in FFA, and normal structure and thickness in OCT. The a-wave amplitudes of the maximum mixed response decreased significantly, and were (15.38±4.36) μV and (13.78±5.52) μV at 2 or 3 days of modeling, respectively. NMDA mice showed a pale retina with vasospasm. ERG revealed that there was no obvious change in latency of a- and b-wave, but significantly decreased amplitude of b-wave at 12 hours and 24 hours after modeling with (72.28±7.18) μV and (65.35±9.18) μV, respectively. ConclusionMicron Ⅳ retinal imaging system is a real-time, non-invasive tool to study the retinal structure and function in animal models of retinal diseases.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content