Objective To establish rabbit models of mixture-infectious endophthalmitis induced by exogenous Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli). Methods A total of 84 eyes of 42 New Zealand white albino rabbits were randomly divided into 4 groups. There were 21 eyes in each group. Rabbit eyes in group 1, 2, 3 and 4 received an intravitreal injection of 0.1 ml of mix bacterium (2times;104 CFU/ ml, including 103 S. aureus and 103 E. coli), S. aureus (104 CFU/ ml), E. coli (104 CFU/ml), and sterilized saline respectively. The eyes were examined by slit-lamp microscopy, ophthalmoscopy, A/B scan, electroretinography (ERG) and bacterial culture of vitreous humors at the timepoints of 6, 12, 24, 48 and 72 hours, and 4, 7, 10, 14 days after intravitreal injection. All eyeballs were then enucleated for histopathological examination. Results Various degrees of inflammatory reactions were presented in the 3 experimental groups after the injection, and the development trend of the disease was nearly the same. In group 1 active intraocular inflammation like anterior chamber exudates, started at 12 hours after injection (which was early than that in group 2 and 3), aggravated between 48 and 72 hours, alleviated slowly from 4 to 7 days, and was obviously better after 10 to 14 days while the corneal neovascularization and vitreous gray opacity begun to form. The bacterial culture was positive in group 1 (100%, 6 hours to 14 days after injection), group 2 (100%, 6 hours to 3 days after injection) and group 3 (100% from 6 hours to 7 days, and 67.67% at 14 days after injection). It was negative for group 2 (7 to 14 days after injection) and group 4 (6 hours to 14 days after injection). The amplitude of ERG b wave dissapeard in group 1 to 3, and decreased less than 30% in group 4 from the 48th hour after injection. Histopathological examination revealed that all intraocular structures infiltrated with inflammatory cells. Conclusion Complicated endophthalmitis rabbit models can be successfully established by intravitreal injection with S. aureus and E. coli.
Objective Mesh infection may occur after incisional hernia repair using prosthetic mesh. Preparation of antibiotics-bonded meshes to prevent infection is one of the solutions. To evaluate the anti-infection effect of polypropylene mesh bonded norvancomycin slow-release microsphere by preparing the rat model of incisional hernia repair contaminatedwith Staphylococcus aureus. Methods The norvancomycin slow-release microspheres were prepared by emulsion and solvent evaporation method and they were bonded to polypropylene mesh (50 mg/mesh). The appearance of the microspheres was observed using scanning electronic microscope (SEM). The content of norvancomycin in microspheres and the release rate of the norvancomycin in norvancomycin-bonded polypropylene mesh were detected using high performance l iquid chromatography method. The rat models of incisional hernia were developed in 40 healthy Sprague Dawley rats, aged 10-11 weeks and weighing 200-250 g. The rats were divided randomly into the experimental group (norvancomycin-bonded polypropylene mesh repair, n=20) and the control group (polypropylene mesh repair, n=20). And then the mesh was contaminated with Staphylococcus aureus. The wound heal ing was observed after operation. At 3 weeks after operation, the mesh and the tissue around the mesh were harvested to perform histological observation and to classify the inflammatory reaction degree. Results The norvancomycin microsphere had integrated appearance and smooth surface with uniform particle diameter, 64% of particlediameter at 60 to 100 μm, and the loading-capacity of norvancomycin was 19.79%. The norvancomycin-bonded polypropylene patch had well-distributed surface and the loading-capacity of norvancomycin was (7.90 ± 0.85) mg/cm2. The release time of norvancomycin in vitro could last above 28 days and the accumulative release rate was 72.6%. The rats of 2 groups all survived to experiment completion. Wound infection occurred in 2 rats of the experimental group (10%) and 20 rats of the control group (100%), showing significant difference (χ2=32.727 3, P=0.000 0). The inflammatory reaction in experimental group was not obvious, grade I in 16 rats and grade II in 4 rats, and numerous inflammatory cell infiltration occurred in the control group, grade II in 3 rats and grade III in 17 rats, showing significant difference (Z=32.314, P=0.000). Conclusion The polypropylene mesh bonded norvancomycin slow-release microsphere has definite anti-infection effect in rat model of incisional hernia repair contaminated by Staphylococcus aureus.
Objective To investigate the incidence rate, molecular epidemiology and risk factors for methicillin-resistant Staphylococcus aureus (MRSA) infection. Methods A total of 119 Staphylococcus aureus strains isolated from January 2016 to December 2020 in general surgery of this hospital were collected retrospectively and divided into MRSA group and methicillin-sensitive Staphylococcus aureus group according to whether or not resistant to oxacillin. The clinical data of all patients infected with Staphylococcus aureus and drug sensitivity of Staphylococcus aureus were collected. Molecular typing was performed by multilocus sequence typing (MLST), resistance gene, virulence gene and biofilm gene were detected by polymerase chain reaction (PCR) method, and a case-control study was used to identify risk factors for MRSA infection. ResultsThe detection rate of MRSA was 57.98% (69/119), mainly was from pus specimens (80.67%, 96/119). The results of MLST showed that the dominant clone types were ST88 (37.68%, 26/69), ST951 (27.54%, 19/69) and ST59 (18.84%, 13/69). The results of PCR showed that the detection rates of mecA, mecC, Aac (6′ )/Aph (2′ ′ ), Aph (3)-Ⅲ, ant (4′ )- Ⅰ a, tetM, qnrA, panton-valentine leukocidin, fibronectin-binding protein A, staphylococcal enterotoxin A, staphylococcal enterotoxin B, α-hemolysins, intracellular adhesion A, staphylococcal accessory regulators A, and fibronectin-binding protein B in 69 strains of MRSA were 100%, 0.00%, 27.54%, 34.78%, 18.84%, 14.49%, 1.45%, 8.70%, 98.55%, 11.59%, 91.30%, 94.20%, 92.75%, 97.10% and 86.96%, respectively. Multivariate analysis showed that hospital transfer, wound infection, catheter related infection, drainage tube and history of cephalosporin using were risk factors for MRSA infection. ConclusionsThe detection rate of MRSA in general surgery of this hospital is high. ST88 is the most common clone type. The carrying rates of resistant-, virulence- and biofilm-related genes are high. Hospital transfer, wound infection, drainage tube, history of cephalosporin using etc. are high risk factors for MRSA infection. It is advised that invasive operation should be reduced, antibiotics should be used rationally, hand hygiene should be paid attention to, environmental sanitation disinfection should be carried out regularly, and the monitoring of MRSA bacteria should be strengthened, so as to reduce and control the infection and spread of MRSA.
Objective To validate the advantage of repairing bone defect by staphylococcus aureus injection carried in collagen membrane. Methods Twentyfour adult New Zealand rabbits were divided into two groups randomly. After the experimental model of standard bone defect had been made by operation, collagen membrane/staphylococcus aureus injection and staphylococcus aureus injection with the same quantity were transplanted in bone defect areas of the two groups respectively. The reconstructed tissues were observed by general method, X-ray, histology, and immunohistochemistry at 2nd、4th、6th、8th week respectively. Results The experimental group showed that new bone proliferated distinctly in bone defect areaand the proliferation lasted long, and no excessive connective tissue in defectarea. X-ray observation showed that there was continual callus growth in transplantation area in early stage and the distribution of new bones was even in the group. Histological observation showed that there were many new bone growth centers in bone defect area, trabecular bones were sequentially distributed, and mature bone replacement was complete. Immunohistochemical examination showed that bone morphogenetic protein (BMP) could be seen for a long time and BMP took up a large part in the new bone tissues. Conclusion Collagen membrane could prevent parenchyma from penetrating into bone defect area and provide room for new bone growth. As the carrier of staphylococcus, collagen membrane could reduce the overflow of staphylococcus and improve its curative effect as well.
Objective To investigate the effect of aureolysin (Aur) on staphylococcus aureus biofilm formation of dacron biomaterial surfaces under different Aur concentration. Methods Ninety dacron biomaterials were divided into 3 groups (group A, group IA, control group) with random number table (30 piece in each group). Dacron biomaterials were put into vials contained staphylococcus aureus (105 CFU/ml) respectively; then Aur was added to make the concentration at 400ng/ml in group A, and group B at 80ng/ml. The thickness and number of staphylococcus aureus biofilm on the surfaces of dacron biomaterials of each group were evaluated by confocal laser microscopy and scanning electron microscopy after incubating 6h, 16h, 24h, 30h, and 48h. Results The thickness and number of staphylococcus aureus biofilm on dacron biomaterials surfaces increased significantly with time dependence in control group. The thickness and number of staphylococcus aureus biofilm in group A were less than those in group B and control group at each time points (P〈0. 05). The thickness and number in group B were significantly decreased than those in control group (P 〈 0. 05). Conclusion The study shows that Aur can effectively inhibit the formation of staphylococcus aureus biofilm on dacron biomaterials surfaces with dose dependence.
OBJECTIVE: To investigate the ability of repairing bone defect with the compound of coralline hydroxyapatite porous (CHAP), fibrin sealant(FS) and staphylococcus aureus injection (SAI), and the feasibility to use the compounds as bone substitute material. METHODS: The animal model of bone defect was made on the bilateral radius of 54 New Zealand white rabbits, which were randomly divided into the experimental group(the defect was repaired with CHAP-FS-SAI), control group(with autograft) and blank control group(the defect was left unrepaired) with 18 rabbits in each group. The ability of bone defect repair was evaluated by gross observation, histopathological study, X-ray and biomechanical analysis 2, 4, 8 and 12 weeks after repair. RESULTS: (1) In the 2nd week, tight fibro-connection could be found between the implant and fracture site and there were many fibroblasts and capillary proliferation with many chondrocytes around CHAP in the experimental group, while only a few callus formed, and chondrocytes, osteoblast and osteoclast existed in the control group. (2) In experimental group and control group, a large quantity of callus was found 4 and 8 weeks; ossification of chondrocytes with weave bone formation were found 4 weeks and many osteocytes and weave bones and laminar bones were found 8 weeks. (3) In the 12th week, the complete ossification of implant with well bone remodeling, a large number of mature osteocytes and laminar were found in experimental group and control group, and CHAP still existed in the experimental group; the defect area filled with fibro-scar tissue and only many fibroblasts could be seen in blank control group. (4) X-ray findings were the following: In experimental and control groups, callus formation could be seen 2 weeks postoperatively, more callus formed 4 weeks, the bone defect area disappeared and CHAP scattered in the callus 8 weeks; the fracture line disappeared and medullary cavity became united (in control group); and in the 12th week, the cortex became continuous, the medullary cavity became united, and remodeling completed, while bone defect was not still united in blank control group. The maximal torque and torsional stiffness in the experimental group is higher than those in the control group 2 weeks (P lt; 0.05), but there was no significant difference (P gt; 0.05) between the two groups 4, 8, 12 weeks after repair. CONCLUSION: The compound of CHAP-FS-SAI has good biological compatibility, and it can be used for one kind of bone substitute material to repair the bone defect.
Objective To observe the inhibitory characteristics of silver nanoparticles (AgNP) on bacterial biofilms and investigate their inhibitory effect on biofilm formation on three common orthopedic biomaterials. Methods The minimal inhibitory concentration (MIC) and minimal biofilm inhibitory concentration (MBIC) of AgNP were determined by microplate dilution assay. Biofilms of Staphylococcus aureus (ATCC 25923) were cultured on three orthopedic biomaterials (titanium alloy, titanium oxide, and stainless steel) and intervened with AgNP at concentrations of 32, 16, 8, 4, 2 and 0 μg/mL to determine the MBICs on the three materials. The effects of AgNP on biofilm formation were analyzed by scanning electron microscopy and measuring optical density. Results The MIC and MBIC of AgNP in the microplate assay were both 16 µg/mL. The MBICs of AgNP on biofilm formation in titanium oxide, titanium alloy, and stainless steel were 16 μg/mL, 32 μg/mL, and 32 μg/mL, respectively. Among the three materials, the lowest optical density was observed on titanium oxide, while the highest was on titanium alloy. Conclusions AgNP has strong antibacterial biofilm characteristics and can prevent the formation of Staphylococcus aureus biofilm in vitro. Biofilm formation is most pronounced on titanium alloy, least on titanium oxide, and intermediate on stainless steel.
ObjectiveTo explore drug resistance, resistant mechanisms and resistant phenotypes of staphylococcus aureus (SA) isolated from wound secretion to macrolides-lincosamides-streptogramins (MLS). MethodsA retrospective design was used to collect clinical data and antimicrobial resistance profiles of SA in the First Affiliated Hospital and the Second Affiliated Hospital of Fujian Medical University and Anxi County Hospital from June, 2008 to October, 2015. SPSS 19.0 software was used for data analysis. ResultsA total of 127 isolates were included. The distribution of four resistant phenotypes of SA to MLS were all susceptibility(S) type (n=48, 37.8%), ML type (n=41, 32.3%), M/iCR+ type (n=22, 17.3%) and MLS type (n=16, 12.6%), respectively; There were three kinds of phenotypes caused by target changing including ML type, M/iCR+ type and MLS type, respectively. Moreover, no moxicaxin, linezolid or tigecyline resistant strain was detected, while quinolons and tetracyclines showed low-level resistant. ConclusionCompared with the different samples, the resistant phenotypes of SA isolated from wound secretion to MLS are few, and the total resistance ratio is low.
Methicillin-resistant Staphylococcus aureus is one of the important pathogens of healthcare-associated infections. In order to prevent and control the transmission of the drug-resistant organism in healthcare facilities, the Healthcare Infection Society and the Infection Prevention Society jointly conducted the guidelines for the prevention and control of methicillin-resistant Staphylococcus aureus in 2021. This article introduces the guide from the background, preparation process, main prevention and control measures and further studies, and compares the guidelines with the current prevention and control measures in China, so as to provide a methodological reference for preparation of the guide for domestic infection prevention and control practitioners, and provide evidence-based prevention and control strategies for clinical practice.
Objective To observe and evaluate the efficacy of continuous drainage with intravenous catheter in the treatment of breast abscess infected by methicillin resistant staphylococcus aureus (MRSA) and to explore the best treatment methods. Methods Sixty cases of breast abscess infected by MRSA were retrospectively analyzed. The patients were divided into continuous drainage group and puncture drainage group according to the treatment. Continuous drainage with 14G intravenous catheter and intermittent aspiration with 20 mL syringe were performed to treat the breast abscesses in the continuous drainage group (n=36) and puncture drainage group (n=24), respectively. Meanwhile, sensitive antibiotics were used according to the results of susceptibility test. The therapeutic effects of the 2 groups were compared. Results There were no significant differences in baseline data between continuous drainage group and puncture drainage group (P>0.05). There was no significant differences of cure rate between the two groups (P=0.717). Compared with the puncture drainage group, the continuous drainage group showed shorter period of time to heal the breast abscess (P=0.001), shorter period of time to control the ache (P=0.038), less punctures (P<0.001) and more daily volume of drainage (P<0.001). No significant differences were found in the period of time to control the fever between the two groups (P=0.127). Conclusions Continuous drainage with intravenous catheter can shorten the course of disease, reduce the suffering of patients, reduce the difficulty of hospital infection prevention and control. It’s an ideal choice for the treatment of breast abscess infected by MRSA.